Skip to main content Accessibility help
×
Home

High-resolution computed tomography in evaluation of cochlear patency in implant candidates: a comparison with surgical findings

  • Giuseppe N. Frau (a1), William M. Luxford (a2), William W. M. LO (a3), Karen I. Berliner (a4) and Fred F. Telischi (a5)...

Abstract

High-resolution computed tomography (HRCT) is important in the evaluation of cochlear implant candidates. This study examines the accuracy of radiological assessment of cochlear patency in relation to findings at the time of surgery. Older and newer HRCT methods and attending and senior radiologist interpretations are compared in a large series of cochlear implant patients.

Subjects were 50 adults (22 to 74 years) and 31 children (2.4 to 11.7 years) who received either a 3M/House or a Nucleus 22-channel cochlear implant. Attending radiologist reports were obtained by chart review and the scans were re-reviewed for this study by a senior radiologist. Accuracy in detecting cochlear ossification ranged from 86.4 per cent for attending radiologists, with all HRCT scans, to 94.7 per cent for the senior radiologist with newer HRCT scans. False positives were rare, but false negatives did occur. Overall, best results were obtained with newer HRCT scans and a senior radiologist.

Knowledge of the presence and extent of cochlear ossification is important to the implant surgeon and for patient counselling. Technical guidelines and a check list for interpretation of results are presented.

Copyright

Corresponding author

William M. Luxford, M.D., House Ear Clinic, 2100 W. Third Street, Los Angeles, CA 90057, USA. Fax: 213-484-5900

References

Hide All
Balkany, T., Gantz, B., Nadol, J. B. Jr (1988) Multichannel cochlear implants in partially ossified cochleas. Annals of Otology, Rhinology and Laryngology 97 (suppl. 135): 37.
Brogan, M., Chakeres, D. W., Schmalbrock, P. (1991) High-resolution 3DFT MR imaging of the endolymphatic duct and soft tissues of the otic capsule. American Journal of Neuroradiologv 12: 111.
Casselman, J. W., Kuhweide, R., Diemling, M., Ampe, W., Dehaene, I., Meeus, L. (1993) Constructive interference in steady state-3DFT MR imaging of the inner ear and cerebellopontine angle. American Journal of Neuroradiology 14: 4757.
Dreisbach, J. N., Balkany, T. J. (1988) The imaging evaluation of the cochlear implant candidate. In American Academy Otolaryngology Head-Neck Surgery Instructional Courses, vol 1. (Johnson, J. T., Blitzer, A., Ossoff, R., Thomas, J. R., eds.), Mosby Year Book, St Louis, pp 175184.
Eisenberg, L. S., Luxford, W. M., Becker, T. S., House, W. F. (1984) Electrical stimulation of the auditory system in children deafened by meningitis. Otolaryngology - Head and Neck Surgery 92: 700705.
Fayad, J., Moloy, P., Linthicutn, F. H. Jr. (1990) Cochlear otosclerosis: does bone formation affect cochlear implant surgery? American Journal of Otology 11: 196200.
Green, J. D. Jr, Marion, M. S., Hinojosa, R. (1991) Labyrinthitis ossificans: histopathologic consideration for cochlear implantation. Otolaryngology-Head and Neck Surgery 104: 320326.
Jackler, R. K., Luxford, W. M., House, W. F. (1987a) Congenital malformations of the inner ear: a classification based on embryogenesis. Laryngoscope 97 (suppl. 40): 214.
Jackler, R. K., Luxford, W. M., House, W. F. (1987b) Sound detection with the cochlear implant in five ears of four children with congenital malformations of the cochlea. Laryngoscope 97 (suppl. 40): 1517.
Jackler, R. K., Luxford, W. M, Schindler, R. A., McKerrow, W. S. (1987 c) Cochlear patency problems in cochlear implantation. Laryngoscope 97: 801805.
Laszig, R., Terwey, B., Ratimer, R. D., Hesse, G. (1988) Magnetic resonance imaging (MRI) and high-resolution computer tomography (HRCT) in cochlear implant candidates. Scandinavian Audiology 17 (suppl. 30): 197200.
Novak, M. A., Fifer, R. C, Barkmeier, J. C, Firsz, J. B. (1990) Labyrinthine ossification after meningitis: its implications for cochlear implantation. Otolaryngology-Head and Neck Surgery 103: 351356.
Shelton, C., Luxford, W. M.Tonokawa, L. L., Lo, W. W. M., House, W. F. (1989) The narrow internal auditory canal in children: a contraindication to cochlear implants. Otolaryngology - Head and Neck Surgery 100: 227231.
Tien, R. D., Felsberg, G. J., Macfall, J. (1992) Fast spin-echo high resolution MR imaging of the inner ear. American Journal of Roentgenology 159: 395398.
Tucci, D. L., Lambert, P. R., Ruth, R. A. (1990) Trends in rehabilitation after cochlear implantation. Archives of Otolaryngology, Head and Neck Surgery 116: 571574.
Wiet, R. J., Pyle, G. M., O'Connor, C. A., Russell, E., Schramm, D. R. (1990) Computed tomography: how accurate a predictor for cochlear implantation? Laryngoscope 100: 687692.
Wolff, A. B., Brown, S. C. (1987) Demographics of meningitisinduced hearing impairment: implications for immunization of children against Hemophilus influenzae type B. American Annals of the Deaf 132: 2630.

Keywords

Related content

Powered by UNSILO

High-resolution computed tomography in evaluation of cochlear patency in implant candidates: a comparison with surgical findings

  • Giuseppe N. Frau (a1), William M. Luxford (a2), William W. M. LO (a3), Karen I. Berliner (a4) and Fred F. Telischi (a5)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.