5 - Synchrotron Radiation

Published online by Cambridge University Press:  24 November 2016

David Attwood
Affiliation:
University of California, Berkeley
Anne Sakdinawat
Affiliation:
SLAC National Accelerator Laboratory
Get access
Type
Chapter
Information
X-Rays and Extreme Ultraviolet Radiation
Principles and Applications
, pp. 148 - 226
Publisher: Cambridge University Press
Print publication year: 2017

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Kim, K.-J., “Characteristics of Synchrotron Radiation,” pp. 565–632 in Physics of Particle Accelerators, AIP Conference Proceedings 184 (Amer. Inst. of Physics, New York, 1989), M. Month and M. Dienes, Editors; also see K.-J. Kim, “Characteristics of Synchrotron Radiation,” X-Ray Data Booklet (Center for X-Ray Optics, Lawrence Berkeley National Laboratory, 1999), Second Edition; K.-J. Kim, “Optical and Power Characteristics of Synchrotron Radiation Sources,” Opt. Engr. 34, 342 (1995).
2. Hofmann, A., The Physics of Synchrotron Radiation (Cambridge University Press, 2004); also “Quasi-Monochromatic Radiation from Undulators,” Nucl. Instrum. and Meth. 152, 17 (1978); and “Theory of Synchrotron Radiation,” Stanford Synchrotron Radiation Laboratory report ACD-Note 38.
3. Duke, P.A., Synchrotron Radiation (Oxford University Press, 2000).
4. Schmüser, P., Dohlus, M.. Rossbach, J. and Behrens, C., Free-Electron Lasers in the Ultraviolet and X-ray Regime (Springer, Heidelberg, 2014).
5. Kim, K.-J., Huang, Z. and Lindberg, R., Synchrotron Radiation and Free Electron Lasers: Principles of Coherent X-Ray Generation (Cambridge University Press, 2017), to be published.
6. Beam parameters for modern synchrotrons worldwide can be found through the website http:tandfonline.com; As an example of a modern, low emittance storage ring, see Chang, S.-L. and Chen, C.-T., “From Taiwan Light Source to Taiwan Photon Source”, Synchrotron Radiation News 26 (4), 32 (2013).Google Scholar
7. Tipler, P.A. and Llewelyn, R.A., Modern Physics (Freeman, New York, 2012), Sixth Edition.
8. Jackson, J.D., Classical Electrodynamics (Wiley, New York, 1999), Third Edition, Chapter 14; also see First Edition (1962), Section 14.4.
9. Green, G.K., Brookhaven National Laboratory, Upton, NY, Report 50522 (also in Report 50595, Vol. II), 1977.
10. Halbach, K., “Physical and Optical Properties of Rare Earth Cobalt Magnets,” Nucl. Instrum. Meth. 187, 109 (1981); also “Permanent Magnet Undulators,” J. Phys. (Paris), 44, Colloq.C1, Suppl. 2, 211 (1983); and N.A. Vinokurov and E.B. Levichev, “Undulators and Wigglers for Production of Radiation and Other Applications,” Uspekhi Fizicheskikh Nauk 185 (90), 917–939 (September 2015).Google Scholar
11. Leighton, R.B., Principles of Modern Physics (McGraw-Hill, New York, 1959), Chapter 12.
12. Kincaid, B.M., “A Short-Period Helical Wiggler as an Improved Source of Synchrotron Radiation,” J. Appl. Phys. 48, 2684 (1977); also see M.R. Howells and B.M. Kincaid, “The Properties of Undulator Radiation,” pp. 315–359 in New Directions in Research with Third Generation Soft X-Ray Synchrotron Radiation Sources (Kluwer, Dordrecht, 1994), A.S. Schlachter and F.J. Wuilleumier, Editors.Google Scholar
13. Walker, R.P. and Diviacco, B., “A Computer Program for Calculating Undulator Radiation and Spectral, Angular, Polarization, and Power Density Properties,” Rev. Sci. Instrum. 63, 392 (1992); also see R.P. Walker, “Interference Effects in Undulator and Wiggler Radiation Sources,” Nucl. Instr. Methods A 335, 328 (1993).Google Scholar
14. Hecht, E., Optics (Addison-Wesley, San Francisco, 2002), Fourth Edition, pp. 50, 313, and 653.
15. Cornacchia, M., “Lattices,” Chapter 2, pp. 30–58 in Synchrotron Radiation Sources: A Primer (World Science, Singapore, 1994), H. Winick, Editor.
16. Kitamura, H., “Future of Synchrotron Radiation,” Kasokuki Kagaku (Accelerator Sci.) 1, 45 (Ionics Publishing, Tokyo, 1986).
17. Born, M. and Wolf, E., Principles of Optics (Cambridge Univ. Press, New York, 1999), Sections 4.8.1 and 4.8.3, pp. 194 and 201, which deal with photometry and brightness.
18. Eriksson, M., Veen, J. Friso van der and Quitman, C., “Diffraction-Limited Storage Rings – a Window to the Science of Tomorrow,J. Synchr. Rad. 21, 837 (September 2014).Google Scholar
19. Tavares, P.F. et al., “The MAX IV Storage Ring Project”, ibid, 862; M. Borlund et al., “Lattice Design Challenges for Fourth-Generation Storage-Ring Light Sources”, ibid, 912; J. Susini et al., “New Challenges in Beamline Instrumentation for the ESRF Upgrade Programme Phase II”, ibid, 986; R. Hettel, “DLSR Design and Plans: an International Overview”, ibid, 843; C. Steier et al., “Towards a Diffraction Limited Upgrade of the ALS,” Proc. IPAC 2016, Busan (May 2016).
20. Schlueter, R.D., “Wiggler and Undulator Insertion Devices,” Chapter 14, p. 377 in Synchrotron Radiation Sources: A Primer (World Science, Singapore, 1994), H. Winick, Editor.
21. Kim, K.-J., “A Synchrotron Radiation Source with Arbitrarily Adjustable Elliptical Polarization,” Nucl. Instrum. and Meth. A 219, 425 (1984).Google Scholar
22. Bahrdt, J., Gaupp, A., Gudat, W. et al., “Circularly Polarized Synchrotron Radiation from the Crossed Undulator at BESSY,” Rev. Sci. Instrum. 63, 339 (1992); R. David, P. Stoppmanns, S.-W. Yu et al., “Circularly Polarized Undulator Radiation from the New Double Crossed Undulator Beamline at BESSY and its First Use for Spin Resolved Auger Electron Emission Spectroscopy,” Nucl. Instrum. and Meth. A 343, 650 (1994).Google Scholar
23. Onuki, H., “Elliptically Polarized Synchrotron Radiation Source with Crossed and Retarded Magnetic Fields,” Nucl. Instrum. Meth. A 246, 94 (1986); H. Onuki, N. Saito and T. Saito, “Undulator Generating any Kind of Elliptically Polarized Radiation,” Appl. Phys. Lett. 52, 173 (1988).Google Scholar
24. Viacco, B. Di and Walker, R.P., “Fields and Trajectories in Some New Types of Permanent Magnet Helical Undulators,” Nucl. Instrum. Meth. A 292, 517 (1990).Google Scholar
25. Sasaki, S., “Analysis for a Planar Variably-Polarizing Undulator,” Nucl. Instrum. and Meth. A 347, 83 (1994); S. Sasaki, K. Kakunori, T. Takada et al., “Design of a New Type of Planar Undulator for Generating Variably Polarized Radiation,” Nucl. Instrum. Meth. A 331, 763 (1993).Google Scholar
26. Kitamura, H., “Present Status of SPring-8 Insertion Devices,” J. Synchr. Rad. 5, 184 (1998).Google Scholar
27. Agui, A. et al., “First Operation of Circular Dichroism Measurements with Periodic Photon-Helicity Switching by a Variably Polarizing Undulator at BL23SU at SPring-8,Rev. Sci. Instrum. 72, 3191 (August 2001); T. Nakatani, A. Agui, H. Aoyagi et al., “Scheme for Precise Correction of Orbit Variation Caused by Dipole Error Field of Insertion Device,” Rev. Sci. Instrum. 76, 055105 (2005).Google Scholar
28. Undulators, Wigglers and their Applications (Taylor and Francis, London, 2003), edited by Hideo Onuki and Pascal Elleaume.
29. Clarke, J.A., The Science and Technology of Undulators and Wigglers (Oxford, 2004).
30. Synchrotron Light Sources and Free Electron Lasers (Springer, Heidelberg, 2015), edited by E. Jaescke, S. Khan, J.R. Schneider and J.B. Hastings, ISBN 978-3-319-04507-8.
31. Gluskin, E., “APS Insertion Devices: Recent Developments and Results,” J. Synchr. Rad. 5, 189 (1998).Google Scholar
32. Kulipanov, G.N., Skrinsky, A.N. and Vinokurov, N.A., “Synchrotron Light Sources and Recent Developments of Accelerator Technology,” J. Synchr. Rad. 5, 176 (1998).Google Scholar
33. Attwood, D.T., Halbach, K. and Kim, K.-J., “Tunable Coherent Radiation,” Science 228, 1265 (June 14, 1985).Google Scholar
34. Kondratenko, A.M. and Skrinsky, A.N., “Use of Radiation of Electron Storage Rings in X-Ray Holography of Objects,” Opt. Spectrosc. (USSR) 42, 189 (February 1977); p. 338 in the original Russian journal.Google Scholar
35. Attwood, D., Kim, K.-J., Wang, N., and Iskander, N., “Partially Coherent Radiation at X-Ray Wavelengths,” J. de Phys. (Paris) 47, C6–203, Suppl. 10 (October 1986).Google Scholar
36. Coïsson, R., “Spatial Coherence of Synchrotron Radiation,” Appl. Opt. 34, 904 (1995); K. Fezzaa, F. Comin, S. Marchesini, R. Cöısson and M. Belakhovsky, “X-Ray Interferometry at ESRF Using Two Coherent Beams from Fresnel Mirrors,” J. X-Ray Sci. Technol. 7, 12 (1997).Google Scholar
37. Abernathy, D.L., Grübel, G., Bauer, S. et al., “Small-Angle X-Ray Scattering Using Coherent Undulator Radiation at ESRF,” J. Synchr. Rad. 5, 37 (1998).Google Scholar
38. Takayama, Y., Tai, R.Z., Hatano, T. et al., “Measurement of the Coherence of Synchrotron Radiation,” J. Synchr. Rad. 5, 456 (1998); Y. Takayama et al., “Relationship between Spatial Coherence of Synchrotron Radiation and Emittance,” J. Synchr. Rad. 5, 1187 (1998).Google Scholar
39. Nugent, K.A., “Coherent Methods in the X-ray Sciences,Advances in Physics 59, 1–99 (2010).Google Scholar
40. The monochromator illustrated in Figure 8.11 is similar to that described in Underwood, J., Gullikson, E., Koike, M. et al., “Calibration and Standards Beamline 6.3.2 at the Advanced Light Source,” Rev. Sci. Instrum. 67(9), 1 (September 1996); also R. Beguiristain, “Thermal Distortion Effects on Beamline Design for High Flux Synchrotron Radiation,” PhD Thesis, Nuclear Engineering Department, University of California at Berkeley, October 1997.Google Scholar
41. Hettrick, M., Underwood, J., Batson, P. and Eckart, M., “Resolving Power of 35,000 in the Extreme Ultraviolet Employing a Grazing Incidence Spectrometer,” Appl. Opt. 27, 200 (January 15, 1988), and references therein.Google Scholar
42. Chesnel, K., Turner, J.J., Pfeifer, M. and Kevan, S.D., “Probing Complex Materials with Coherent Soft X-rays,Applied Physics A 92, 431 (2008).Google Scholar
43. Turner, J. J., Thomas, K. J., Hill, J. P. et al., “Orbital Domain Dynamics in a Doped Manganite,New J. Phys. 10, 053023 (2008).Google Scholar
44. Chen, S.-W., Guo, H., Seu, K. A. et al., “Jamming Behavior of Dynamics in a Spiral Antiferromagnetic System,Phys. Rev. Lett. 110, 217201 (2013).Google Scholar
45. Chang, C., “Diffractive Optical Elements Based on Fourier Optical Techniques: A New Class of Optics for Extreme Ultraviolet and Soft S-ray wavelengths,Applied Optics 41, 7384 (December 10, 2002); “Coherence Techniques at EUV Wavelengths”, PhD Thesis, EECS, UC Berkeley (2002).Google Scholar
46. Chang, C., Sakdinawat, A.E., Fischer, P., Anderson, E.H. and Attwood, D., “Single-Element Objective Lens for Soft X-ray Differential Interference Contrast Microscopy,” Optics Lett. 31, 1564 (2006).Google Scholar
47. Sakdinawat, A.E. and Liu, Y.W., “Soft X-ray Microscopy Using Spiral Zone Plates,” Optics Lett. 32, 2635 (2007).Google Scholar
48. Sakdinawat, A.E. and Liu, Y.W., “Phase Contrast Soft X-ray Microscopy Using Zernike Zone Plates,” Optics Express 16, 1559 (2008).Google Scholar
49. Sakdinawat, A.E., “Extended Depth of Field Soft X-ray Microscopy”, unpublished (2009).
50. Sakdinawat, A.E., “Contrast and Resolution Enhancement Techniques for Soft X-ray Microscopy”, PhD Thesis, Bioengineering, UC Berkeley (2008).
51. Rosfjord, K.M., Liu, Y.W. and Attwood, D.T., “Tunable Coherent Soft X-Rays,” IEEE J. Select. Topics Quant. Electr. 10, 1405 (November/December 2004).Google Scholar
52. Rosfjord, K.M., “Tunable Coherent Radiation at Soft X-ray Wavelengths: Generation and Interferometric Applications”, PhD Thesis, EECS, UC Berkeley (2004).
53. Patterson, D., Allman, B.E., McMahon, P.J. et al., “Spatial Coherence Measurement of X-ray Undulator Radiation,Optics Commun. 195, 79 (August 1, 2001); I.K. Robinson, I.A. Vartanyants, G.J. Williams and M.A. Pitney, “Reconstruction of the Shapes of Gold Nanocrystals Using Coherent X-ray Diffraction,” Phys. Rev. Lett. 87 (19), 195505 (November 5, 2001).Google Scholar
54. Lin, J.J.A., Patterson, D., Peele, A.G. et al., “Measurement of the Spatial Coherence Function of Undulator Radiation using a Phase mask,Phys. Rev. Lett. 90, 074801 (February 21, 2003).Google Scholar
55. Tran, C.Q., Peele, A.G., Roberts, A. et al., “Synchrotron Beam Coherence: A Spatially resolved Measurement,Optics Lett. 30, 204 (January 15, 2005).Google Scholar
56. Tran, C.Q., Peele, A.G., Patterson, D. et al., “Phase Space Density Measurement of Interfering X-rays”, J. Electr. Spectrosc. Rel. Phenom. 144, 947 (March 7, 2005).Google Scholar
57. Tran, C.Q., Peele, A.G., Roberts, A. et al., “X-ray Imaging: A Generalized Approach using Phase-Space Tomography,JOSA 22, 1691 (August 2005).Google Scholar
58. Pfeiffer, M.A., Williams, G.J., Vartanyants, I.A., Harder, R. and Robinson, I.K., “Three-Dimensional Mapping of a Deformation Field Inside a Nanocrystal,Nature 442, 63 (July 6, 2006).Google Scholar
59. Leake, S.J., Newton, M.C., Harder, R. and Robinson, I.K., “Longitudinal Coherence Function in X-ray Imaging of Crystals,Optics Expr. 17, 15853 (August 31, 2009).Google Scholar
60. Leake, S.J., Harder, R. and Robinson, I.K., “Coherent Diffractive Imaging of Solid State Reactions in Zinc Oxide Crystals,New J. Phys. 13, 113009 (2011).Google Scholar
61. Cha, W., Jeong, N.C., Song, S. et al., “Core-Shell Strain Structure of Zeolite Microcrystals,Nature Mat. 12, 729 (July 7, 2013).Google Scholar
62. Robinson, I. and Harder, R., “Coherent x-ray Diffraction Imaging of Strain at the Nanoscale,Nature Mat. 8, 291 (April 2009).Google Scholar
63. Clark, J.N., Huang, X., Harder, R. and Robinson, I.K., “High-Resolution Three-Dimensional Partially Coherent Diffraction Imaging,Nature Commun. 3, 993 (August 7, 2012).Google Scholar
64. Clark, J.N., Huang, X., Harder, R.J. and Robinson, I.K., “Dynamic Imaging Using Ptychography,Phys. Rev. Lett. 112, 113901 (March 21, 2014).Google Scholar

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×