Chapter 15 - Intrapartum Evaluation of the Fetus

from Section 2 - Pregnancy, Labor, and Delivery Complications Causing Brain Injury

Published online by Cambridge University Press:  13 December 2017

David K. Stevenson
Affiliation:
Stanford University, California
William E. Benitz
Affiliation:
Stanford University, California
Philip Sunshine
Affiliation:
Stanford University, California
Susan R. Hintz
Affiliation:
Stanford University, California
Maurice L. Druzin
Affiliation:
Stanford University, California
Get access

Summary

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Chapter
Information
Publisher: Cambridge University Press
Print publication year: 2017

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Hon, EH. The electronic evaluation of the fetal heart rate: preliminary report. Am J Obstet Gynecol 1958; 75(6): 1215–30.CrossRefGoogle ScholarPubMed
Hon, EH, Hess, OW. Instrumentation of fetal electrocardiography. Science 1957; 125(3247): 553–4.Google Scholar
Benson, RC, et al. Fetal heart rate as a predictor of fetal distress: a report from the collaborative project. Obstet Gynecol 1968; 32(2): 259–66.Google Scholar
Lilien, AA. Term intrapartum fetal death. Am J Obstet Gynecol 1970; 107(4): 595603.Google Scholar
Jepson, JH. Factors influencing oxygenation in mother and fetus. Obstet Gynecol 1974; 44(6): 906–14.Google Scholar
Quilligan, EJ, Paul, RH. Fetal monitoring: is it worth it? Obstet Gynecol 1975; 45(1): 6100Google ScholarPubMed
Yeh, SY, DIaz, F, Paul, RH. Ten-year experience of intrapartum fetal monitoring in Los Angeles County/University of Southern California Medical Center. Am J Obstet Gynecol 1982; 143(5): 496500.CrossRefGoogle ScholarPubMed
MacDonald, D, et al. The Dublin randomized controlled trial of intrapartum fetal heart rate monitoring. Am J Obstet Gynecol 1985; 152(5): 524–39.Google Scholar
Parer, JT. Roundtable: Part I. The Dublin trial of fetal heart rate monitoring: the final word? Birth 1986; 13(2): 119–21.CrossRefGoogle ScholarPubMed
Grant, A, et al. Cerebral palsy among children born during the Dublin randomised trial of intrapartum monitoring. Lancet 1989; 8674(2): 1233–6.Google Scholar
Banta, HD, Thacker, SB. Electronic fetal monitoring. Lessons from a formative case of health technology assessment. Int J Technol Assess Health Care 2002; 18(4): 762–70.Google Scholar
Centers for Disease Control. Rates of cesarean delivery–United States, 1991. MMWR Morb Mortal Wkly Rep 1993; 42(15): 285–9.Google Scholar
Chez, BF, Baird, SM. Electronic fetal heart rate monitoring: where are we now? J Perinat Neonatal Nurs 2011; 25(2): 180–92.Google ScholarPubMed
Alfirevic, Z, Devane, D, Gyte, GM. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2013; 5: CD006066.Google Scholar
Maso, G, et al. Intrapartum fetal heart rate monitoring interpretation in labour: a critical appraisal. Minerva Ginecol 2015; 67(1): 6579.Google ScholarPubMed
Redman, C. 45 years of fetal heart rate monitoring in BJOG. BJOG 2015; 122(4): 536.Google Scholar
Little, WJ. On the influence of abnormal parturition, difficult labours, premature birth, and asphyxia neonatorum, on the mental and physical condition of the child, especially in relation to deformities. Clin Orthop Relat Res 1966; 46: 722.Google ScholarPubMed
Hon, EH. Apparatus for continuous monitoring of the fetal heart rate. Yale J Biol Med 1960; 32(5): 397–9.Google Scholar
Haverkamp, AD, et al. The evaluation of continuous fetal heart rate monitoring in high-risk pregnancy. Am J Obstet Gynecol 1976; 125(3): 310–20.CrossRefGoogle ScholarPubMed
Parer, JT. Fetal heart-rate monitoring. Lancet 1979; 2(8143): 632–3.Google Scholar
Thacker, SB, Stroup, DF, Peterson, HB. Efficacy and safety of intrapartum electronic fetal monitoring: an update. Obstet Gynecol 1995; 86(4 Pt 1): 613–20.Google Scholar
Larma, JD, et al. Intrapartum electronic fetal heart rate monitoring and the identification of metabolic acidosis and hypoxic-ischemic encephalopathy. Am J Obstet Gynecol 2007; 197(3): 301.e18.Google Scholar
Nelson, KB, et al. Uncertain value of electronic fetal monitoring in predicting cerebral palsy. N Engl J Med 1996; 334(10): 613–8.Google Scholar
Spong, CY. Electronic fetal heart rate monitoring: another look. Obstet Gynecol 2008; 112(3): 506–7.CrossRefGoogle ScholarPubMed
Grivell, RM, et al. Antenatal cardiotocography for fetal assessment. Cochrane Database Syst Rev 2015; 9: CD007863.Google Scholar
Finnemore, A, Groves, A. Physiology of the fetal and transitional circulation. Semin Fetal Neonatal Med 2015; 20(4): 210–6.Google Scholar
Thornburg, KL, Louey, S. Uteroplacental circulation and fetal vascular function and development. Curr Vasc Pharmacol 2013; 11(5): 748–57.Google Scholar
Zhang, L. Uteroplacental circulation and maternal/fetal health. Curr Vasc Pharmacol 2013; 11(5): 543.Google Scholar
Richardson, BS. Fetal adaptive responses to asphyxia. Clin Perinatol 1989; 16(3): 595611.Google Scholar
Sadovsky, G, Nicolaides, KH. Reference ranges for fetal heart rate patterns in normoxaemic nonanaemic fetuses. Fetal Ther 1989; 4(2–3): 61–8.Google Scholar
Martin, CB, Gingerich, B. Uteroplacental physiology. JOGN Nurs 1976; 5(5 Suppl.):16s25s.Google Scholar
Anderson, PA, et al. In utero right ventricular output in the fetal lamb: the effect of heart rate. J Physiol 1987; 387: 297316.Google Scholar
Anderson, PA, et al. The effect of heart rate on in utero left ventricular output in the fetal sheep. J Physiol 1986; 372: 557–73.CrossRefGoogle ScholarPubMed
National Institute of Child Health and Human Development. Electronic fetal heart rate monitoring: research guidelines for interpretation. National Institute of Child Health and Human Development Research Planning Workshop. Am J Obstet Gynecol 1997; 177(6): 1385–90.Google Scholar
Parer, JT, Ikeda, T, King, TL. The 2008 National Institute of Child Health and Human Development report on fetal heart rate monitoring. Obstet Gynecol 2009; 114(1): 136–8.Google Scholar
American College of Obstetrics and Gynecologists. Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles (ACOG Practice Bulletin No. 106). Obstet Gynecol 2009; 114(1): 192202.Google Scholar
Soncini, E, et al. Intrapartum fetal heart rate monitoring: evaluation of a standardized system of interpretation for prediction of metabolic acidosis at delivery and neonatal neurological morbidity. J Matern Fetal Neonatal Med 2014; 27(14): 1465–9.Google Scholar
Parer, JT, Ikeda, T. A framework for standardized management of intrapartum fetal heart rate patterns. Am J Obstet Gynecol 2007; 197(1): 26.e16.CrossRefGoogle ScholarPubMed
Park, YS, et al. Difference of fetal heart rate accelerations based on 10 and 15 beats per minute. J Obstet Gynaecol Res 2010; 36(2): 291–5.CrossRefGoogle ScholarPubMed
Salamalekis, E, et al. Computerized analysis of fetal heart rate variability using the matching pursuit technique as an indicator of fetal hypoxia during labor. J Matern Fetal Neonatal Med 2006; 19(3): 165–9.CrossRefGoogle ScholarPubMed
Ross, MG, et al. Correlation of arterial fetal base deficit and lactate changes with severity of variable heart rate decelerations in the near-term ovine fetus. Am J Obstet Gynecol 2013; 208(4): 285.e16.CrossRefGoogle ScholarPubMed
Paul, RH, et al. Clinical fetal monitoring. VII. The evaluation and significance of intrapartum baseline FHR variability. Am J Obstet Gynecol 1975; 123(2): 206–10.Google Scholar
Parer, JT, et al. Fetal acidemia and electronic fetal heart rate patterns: is there evidence of an association? J Matern Fetal Neonatal Med 2006; 19(5): 289–94.Google Scholar
Ozden, S, Demirci, F. Significance for fetal outcome of poor prognostic features in fetal heart rate traces with variable decelerations. Arch Gynecol Obstet 1999; 262(3–4): 141–9.Google Scholar
Pillai, M, James, D. The development of fetal heart rate patterns during normal pregnancy. Obstet Gynecol 1990; 76(5 Pt 1): 812–6.Google Scholar
Honjo, S, Yamaguchi, M. Umbilical artery blood acid-base analysis and fetal heart rate baseline in the second stage of labor. J Obstet Gynaecol Res 2001; 27(5): 249–54.Google Scholar
Reddy, A, Moulden, M, Redman, CW. Antepartum high-frequency fetal heart rate sinusoidal rhythm: computerized detection and fetal anemia. Am J Obstet Gynecol 2009; 200(4): 407.e16.Google Scholar
Egley, C. The clinical significance of intermittent sinusoidal fetal heart rate. Am J Obstet Gynecol 1999; 181(4): 1041–2.Google Scholar
Frasch, MG, et al. Correlating multidimensional fetal heart rate variability analysis with acid-base balance at birth. Physiol Meas 2014; 35(12): L112.Google Scholar
Uccella, S, et al. Interobserver reliability to interpret intrapartum electronic fetal heart rate monitoring: does a standardized algorithm improve agreement among clinicians? J Obstet Gynaecol 2015; 35(3): 241–5.Google Scholar
Torres, J, De Vries, R, Low, LK. Consumer information on fetal heart rate monitoring during labor: a content analysis. J Perinat Neonatal Nurs 2014; 28(2): 135–43.Google ScholarPubMed
Yudkin, PL, et al. Assessing the contribution of birth asphyxia to cerebral palsy in term singletons. Paediatr Perinat Epidemiol 1995; 9(2): 156–70.Google Scholar
Nelson, KB, Blair, E. Prenatal factors in singletons with cerebral palsy born at or near term. N Engl J Med 2015; 373(10): 946–53.Google Scholar
Macones, GA, et al. The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet Gynecol 2008; 112: 661–6.Google Scholar
Skupski, DW, Eglington, GS. Intrapartum fetal stimulation tests: a meta-analysis. Obstet Gynecol 2002; 100(4): 830.Google ScholarPubMed
Lazebnik, N, et al. Response of fetal heart rate to scalp stimulation related to fetal acid-base status. Am J Perinatol 1992; 9(4): 228–32.CrossRefGoogle ScholarPubMed
East, CE, et al. Vibroacoustic stimulation for fetal assessment in labour in the presence of a nonreassuring fetal heart rate trace. Cochrane Database Syst Rev 2013; 1: CD004664.Google Scholar
Westgren, M, et al. Lactate compared with pH analysis at fetal scalp blood sampling: a prospective randomised study. Br J Obstet Gynaecol 1998; 105(1): 2933.Google Scholar
East, CE, et al. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 2015; 5: CD006174.Google Scholar
Garite, TJ, et al. A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. Am J Obstet Gynecol 2000; 183(5): 1049–58.Google Scholar
Yam, J, Chua, S, Arulkumaran, S. Intrapartum fetal pulse oximetry. I. Principles and technical issues. Obstet Gynecol Surv 2000; 55(3): 163–72.Google Scholar
Bloom, SL, et al. Fetal pulse oximetry and cesarean delivery. N Engl J Med 2006; 355(21): 2195–202.Google Scholar
Amer-Wahlin, I, et al. Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial. Lancet 2001; 358(9281): 534–8.CrossRefGoogle ScholarPubMed
Potti, S, Berghella, V. ST waveform analysis versus cardiotocography alone for intrapartum fetal monitoring: a meta-analysis of randomized trials. Am J Perinatol 2012; 29(8): 657–64.Google ScholarPubMed
Salmelin, A, et al. Fetal monitoring with computerized ST analysis during labor: a systematic review and meta-analysis. Acta Obstet Gynecol Scand 2013; 92(1): 2839.Google Scholar
Kessler, J, Moster, D, Albrechtsen, S. Delay in intervention increases neonatal morbidity in births monitored with cardiotocography and ST-waveform analysis. Acta Obstet Gynecol Scand 2014; 93(2): 175–81.Google Scholar
Olofsson, P, et al. A critical appraisal of the evidence for using cardiotocography plus ECG ST interval analysis for fetal surveillance in labor. I. the randomized controlled trials. Acta Obstet Gynecol Scand 2014; 93(6): 556–68.Google ScholarPubMed
Westerhuis, ME, et al. Identification of cases with adverse neonatal outcome monitored by cardiotocography versus ST analysis: secondary analysis of a randomized trial. Acta Obstet Gynecol Scand 2012; 91(7): 830–7.Google Scholar
Belfort, MA, et al. A randomized trial of intrapartum fetal ECG ST-segment analysis. N Engl J Med 2015; 373(7): 632–41.Google Scholar
Neilson, JP. Fetal electrocardiogram (ECG) for fetal monitoring during labour. Cochrane Database Syst Rev 2013; 5: CD000116.Google Scholar
Sletten, J, Kessler, J. QRS abnormalities of the fetal electrocardiogram, and their implications for ST-interval analysis during labor. Acta Obstet Gynecol Scand 2015; 94(10): 1128–35.Google Scholar
Stampalija, T, et al. Fetal and maternal heart rate confusion during intra-partum monitoring: comparison of trans-abdominal fetal electrocardiogram and Doppler telemetry. J Matern Fetal Neonatal Med 2012; 25(8): 1517–20.CrossRefGoogle ScholarPubMed
Signorini, MG, Fanelli, A, Magenes, G. Monitoring fetal heart rate during pregnancy: contributions from advanced signal processing and wearable technology. Comput Math Methods Med, 2014; 2014: 707581.Google Scholar
Adam, J. The future of fetal monitoring. Rev Obstet Gynecol 2012; 5: 132e136e.Google Scholar
Hamilton, EF, Warrick, PA. New perspectives in electronic fetal surveillance. J Perinat Med 2013; 41(1): 8392.Google Scholar
Chakladar, A, Adams, H. Dangers of listening to the fetal heart at home. BMJ 2009; 339: b4308.Google Scholar

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×