Book contents
- Frontmatter
- Dedication
- Contents
- Preface to the first edition
- Preface to the second edition
- Acknowledgements
- Notation
- Acronyms and abbreviations
- Part 1 Reinforced concrete
- 1 Introduction
- 2 Design properties of materials
- 3 Ultimate strength analysis and design for bending
- 4 Deflection of beams and crack control
- 5 Ultimate strength design for shear
- 6 Ultimate strength design for torsion
- 7 Bond and stress development
- 8 Slabs
- 9 Columns
- 10 Walls
- 11 Footings, pile caps and retaining walls
- Part 2 Prestressed concrete
- Appendix A Elastic neutral axis
- Appendix B Critical shear perimeter
- Appendix C Strut-and-tie modelling of concrete structures
- Appendix D Australian Standard precast prestressed concrete bridge girder sections
- References
- Index
9 - Columns
from Part 1 - Reinforced concrete
- Frontmatter
- Dedication
- Contents
- Preface to the first edition
- Preface to the second edition
- Acknowledgements
- Notation
- Acronyms and abbreviations
- Part 1 Reinforced concrete
- 1 Introduction
- 2 Design properties of materials
- 3 Ultimate strength analysis and design for bending
- 4 Deflection of beams and crack control
- 5 Ultimate strength design for shear
- 6 Ultimate strength design for torsion
- 7 Bond and stress development
- 8 Slabs
- 9 Columns
- 10 Walls
- 11 Footings, pile caps and retaining walls
- Part 2 Prestressed concrete
- Appendix A Elastic neutral axis
- Appendix B Critical shear perimeter
- Appendix C Strut-and-tie modelling of concrete structures
- Appendix D Australian Standard precast prestressed concrete bridge girder sections
- References
- Index
Summary
Introduction
Columns exist in all conventional building structures. Whereas beams, slabs or even trusses may be used to span the floors, columns carry loads vertically, floor by floor, down to the foundations. Even in specialised systems such as shear-wall, shear-core and framed-tube structures, columns are used to support parts of the floor areas.
Figure 9.1(1)a shows a portion of a three-dimensional building frame. For the purposes of discussion on the role of columns, the frame may be taken as representative of other popular building systems, such as multistorey flat slabs, as well as beam/slab and column structures. At each level, the floor spans in both the x and z directions. As a result, bending occurs in both the x–y and y–z planes. Thus, for a typical column AB, the forces acting at the top end, or joint A, include:
N, the axial force equal to the portion of the vertical load (from the floor immediately above) to be carried by column AB plus the axial load transmitted by the column above (i.e. column CA)
Mx, the bending moment about the z-axis
Mz, the bending moment about the x-axis.