Skip to main content Accessibility help
×
Home

Multi-Energy X-Ray Tomography of an Optical Fiber: The Role of Spatial Averaging

  • Zachary H. Levine (a1), Adele P. Peskin (a2), Edward J. Garboczi (a3) and Andrew D. Holmgren (a4) (a5)

Abstract

Using a commercial X-ray tomography instrument, we have obtained reconstructions of a graded-index optical fiber with voxels of edge length 1.05 µm at 12 tube voltages. The fiber manufacturer created a graded index in the central region by varying the germanium concentration from a peak value in the center of the core to a very small value at the core-cladding boundary. Operating on 12 tube voltages, we show by a singular value decomposition that there are only two singular vectors with significant weight. Physically, this means scans beyond two tube voltages contain largely redundant information. We concentrate on an analysis of the images associated with these two singular vectors. The first singular vector is dominant and images of the coefficients of the first singular vector at each voxel look are similar to any of the single-energy reconstructions. Images of the coefficients of the second singular vector by itself appear to be noise. However, by averaging the reconstructed voxels in each of several narrow bands of radii, we can obtain values of the second singular vector at each radius. In the core region, where we expect the germanium doping to go from a peak value at the fiber center to zero at the core-cladding boundary, we find that a plot of the two coefficients of the singular vectors forms a line in the two-dimensional space consistent with the dopant decreasing linearly with radial distance from the core center. The coating, made of a polymer rather than silica, is not on this line indicating that the two-dimensional results are sensitive not only to the density but also to the elemental composition.

Copyright

Corresponding author

*Author for correspondence: Adele P. Peskin, E-mail: adele.peskin@nist.gov

Footnotes

Hide All

This contribution of NIST, an agency of the US government, is not subject to copyright.

Footnotes

References

Hide All
Alvarez, RE (2013). Dimensionality and noise in energy selective x-ray imaging, Med Phys 40, 111909.
Alvarez, RE & Macovski, A (1976). Energy-selective reconstructions in x-ray computerized tomography, Phys Med Biol 21, 733744.
Berger, MJ, Hubbell, JH, Seltzer, SM, Chang, J, Coursey, JS, Sukumar, R, Zucker, DS & Olsen, K (2016). Xcom: Photon cross sections database. Available at http://www.nist.gov/pml/data/xcom/index.cfm (retrieved October 5, 2016).
Bidola, PM, Zanette, I, Achterhold, K, Holzner, C & Pfeiffer, F (2015). Optimization of propagation-based phase-contrast imaging at a laboratory setup, Opt Express 23, 3000030013.
Chiesura, G, Luyckx, G, Veot, E, Lammens, N, Paepegem, WV, Degrieck, J, Dierick, M, Hoorebeke, LV, Van-derniepen, P, Sulejmani, S, Sonnenfeld, C, Geernaert, T & Berghmans, F (2015). A micro-computed tomography technique to study the quality of fibre optics embedded in composite materials, Sensors 15, 1085210871.
Clark, DP & Badea, CT (2015). Spectral deblurring: an algorithm for high-resolution, hybrid spectral CT, Proc SPIE 9412, 9412.
Clark, DP & Badea, CT (2017). Hybrid spectral CT reconstruction, Plos One 12(7), e0180324. Available at https://doi.org/10.1371/journal.pone.0180324.
Dichiro, G, Brooks, RA, Kessler, RM, Johnston, GS, Jones, AE, Herdt, JR & Sheridan, WT (1979). Tissue signatures with dual-energy computed tomography, Radiology 131, 521523.
Genant, HK & Boyd, D (1977). Quantitative bone mineral analysis using dual energy computed tomography, Invest Radiol 12, 545555.
Ghassemian, H (2016). A review of remote sensing image fusion methods, Inf Fusion 32, 7589.
Golub, GH & Van Loan, CF (1983). Matrix Computations. Baltimore, Maryland: Johns Hopkins University Press, pp. 16ff.
Gureyev, TE, Mayo, SC, Myers, DE, Nesterets, Y, Paganin, DM, Pogany, A, Stevenson, AW & Wilkins, SW (2009). Refracting Röntgen's rays: Propagation-based x-ray phase contrast for biomedical imaging, J Appl Phys 105, 102005.
Hansen, PC (1990). Truncated singular value decomposition solutions to discrete ill-posed problems with ill-determined numerical rank, SIAM. J Sci Stat Comput 11, 503518.
Harms, J, Wang, T, Petrongolo, M, Niu, T & Zhu, L (2016). Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization, Med Phys 43, 26762686.
Heismann, BJ, Leppert, J & Stierstorfer, K (2003). Density and atomic number measurements with spectral x-ray attenuation method, J Appl Phys 94, 20732079.
Hernandez, AM & Boone, JM (2014). Tungsten anode spectral model using interpolating cubic splines: Unfiltered x-ray spectra from 20 kV to 640 kV, Med Phys 41, 042101.
Hounsfield, GN (1980). Computed medical imaging, Med Phys 7, 283290.
Koike, S, Yanagi, S, Ueno, Y, Suzuki, K, Takahashi, T, Uesugi, K, Takeuchi, A, Hoshino, M, Suzuki, Y & Watanabe, Y (2013). Nondestructive three-dimensional observation of the influence of zirconium inclusions in laser-irradiated fusion-spliced optical fiber on core structure changes using synchrotron radiation x-ray micro-computed tomography, Jap J Appl Phys 52, 111.
Li, HT, Kingston, AM, Myers, GR, Beeching, L & Sheppard, AP (2018). Linear iterative near-field phase retrieval (LIPR) for dual-energy x-ray imaging and material discrimination, J Optical Soc Amer. A-Optics Image Science and Vision 35, A30A39.
Maier, DS, Schock, J & Pfeiffer, F (2017). Dual-energy micro-CT with a dual-layer, dual-color, single-crystal scintillator, Opt Express 25, 69246935.
Mayo, S, Stevenson, A & Wilkins, S (2012). In-line phase-contrast x-ray imaging and tomography for materials science, Materials (Basel) 5, 937965.
McCullough, EC (1975). Photon attenuation in computed tomography, Med Phys 2, 307320.
McDavid, WD, Waggener, RG & Payne, WH, and Dennis, MJ (1975). Spectral effects on three-dimensional reconstruction from x rays, Med Phys 2, 321324.
Paziresh, M, Kingston, AM, Latham, SJ, Fullagar, WK & Myers, GM (2016). Tomography of atomic number and density of materials using dual-energy imaging and the Alvarez and Macovski attenuation model, J Applied Phys 119, 214901.
Petrongolo, M, Dong, X & Zhu, L (2015). A general framework of noise suppression in material decomposition for dual-energy CT, Med Phys 42, 48484862.
Sandoghchi, SR, Jasion, GT, Wheeler, NV, Jain, S, Lian, Z, Wooler, JP, Boardman, RP, Baddela, N, Chen, Y & Hayes, J (2014). X-ray tomography for structural analysis of microstructured and multimaterial optical fibers and preforms, Opt Express, 22, 2618126192.
Teles, AP, Lima, I & Lopes, RT (2016). Rock porosity quantification by dual-energy X-ray computed microtomography, Micron 83, 7278.
Thomas, C, Ranchin, T, Wald, L & Chanussot, J (2008). Synthesis of multispectral images to high spatial resolution: A critical review of fusion methods based on remote sensing physics, IEEE Trans Geosci Remote Sens 46, 13011312.
ThorLabs (2016). Thorlabs gif625. Available at https://www.thorlabs.com/search/thorsearch.cfm?search=gif625 (retrieved September 30, 2016).
Tsuchiyama, A, Nakano, T, Uesugi, K, Uesugi, M, Takeuchi, A, Suzuki, Y, Noguchi, R, Matsumoto, T, Matsuno, J, Nagano, T, Imai, Y, Nakamura, T, Ogami, T, Noguchi, T, Abe, M, Yada, T & Fujimura, A (2013). Analytical dual-energy microtomography: A new method for obtaining three-dimensional mineral phase images and its application to Hayabusa samples, Geochim Cosmochim Acta 116, 516.
Van Geet, M, Swennen, R & Wevers, M (2000). Quantitative analysis of reservoir rocks by microfocus X-ray computerised tomography, Sedimentary Geol 132, 2536.
Victor, RA, Prodanovic, M & Torres-Verdin, JC (2017). Monte Carlo approach for estimating density and atomic number from dual-energy computed tomography images of carbonate rocks, Geophys Res-Solid Earth 122, 98049824.
Weaver, JE & Huddleston, AL (1985). Attenuation coefficients of body tissues using principal-components analysis, Med Phys 12, 4045.
Wilkins, SW, Gureyev, TE, Gao, D, Pogany, A & Stevenson, AW (1996). Phase-contrast imaging using polychromatic hard X-rays, Nature 384, 335338.
Williams, GP (2001). Electron Binding Energies, in X-ray Data Booklet, 2nd ed. Thompson, AC & Vaughan, D (Eds.), Berkeley, CA: Center for X-Ray Optics, Advanced Light Source. Chap. 1.1, p. 3.
Xiaoyu, J, Page, RL, Chaudhuri, S, Liu, W, Yu, SY, Mohney, SE, Badding, JV, and Gopalan, V (2017). Single-Crystal Germanium Core Optoelectronic Fibers, Advanced Optical Materials 5, 1600592.
Xue, Y, Ruan, R, Hu, X, Kuang, Y, Wang, J, Long, Y & Niu, T (2017). Statistical image-domain multimaterial decomposition for dual-energy CT, Med Phys 44, 886901.
Yu, B, Bradley, RS, Soutis, C & Withers, PJ (2016). A comparison of different approaches for imaging cracks in composites by X-ray microtomography. Phil Trans R Soc A 374, 20160037.
Zeiss (2016). Zeiss Xradia 520 versa your x-ray microscope for submicron x-ray imaging. Available at http://www.zeiss.com/microscopy/us/products/x-ray-microscopy/zeiss-xradia-520-versa.html (retrieved October 14, 2016).

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed