Skip to main content Accessibility help
×
Home
Hostname: page-component-559fc8cf4f-xbbwl Total loading time: 0.251 Render date: 2021-03-02T15:04:24.114Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

The repeatability of echocardiographic determination of right ventricular output in the newborn

Published online by Cambridge University Press:  15 August 2006

B. Tsai-Goodman
Affiliation:
Department of Child Health, St. Michael's Hospital, Bristol, UK
R. P. Martin
Affiliation:
Department of Paediatric Cardiology, Royal Hospital For Sick Children, Bristol, UK
N. Marlow
Affiliation:
Department of Child Health, St. Michael's Hospital, Bristol, UK
J. R. Skinner
Affiliation:
Department of Paediatric Cardiology, Royal Hospital For Sick Children, Bristol, UK

Abstract

Background: Non-invasive measurement of left ventricular output has been shown to be a repeatable technique. Little is known about the repeatability using echocardiography in determining pulmonary arterial diameters or right ventricular output. Aims: To find the most repeatable point at which to measure pulmonary arterial diameter, and to compare the repeatability of determining right ventricular output with left ventricular output. Methods: We assessed the Intra-observer and inter-observer repeatability for measuring the diameter of the pulmonary trunk in 24 term and 26 preterm infants, respectively. Interobserver repeatability was assessed for the diameters of the pulmonary trunk and aorta, for stroke distance, and for left and right ventricular output. Results: The coefficients of variation for intra-observer repeatability were 4%, 7.5% and 9% respectively for measurements of the pulmonary valve, the pulmonary trunk, and the right ventricular outflow tract. There were significant differences between observers for measurement of the pulmonary trunk (p< 0.001) and right ventricular outflow tract (p= 0.011) but not for the pulmonary valve measured in either its long (p= 0.22) or short axis (p= 0.22). Significant differences between observers were also found for the pulmonary stroke distance measured in the long axis (p= 0.004) and aortic diameter at end-diastole (p< 0.001). The other parameters did not differ significantly and were used to calculate right and left ventricular output, respectively. Mean left ventricular output was 241 mls/kg/min, with mean differences between observers of 0.6 mls/kg/min (95% confidence interval (CI): −39.2 to 40.3 mls/kg/min). Mean right ventricular output was 255 mls/kg/min, with mean differences of 0.3 mls/kg/min (95% CI: −24.1 to 23.4 mls/kg/min). Conclusion: Measuring the diameter of the pulmonary trunk at the base of the valvar hinge points was most repeatable. Repeatability of right ventricular output was similar to that of left, with absolute values similar to those published by other workers.

Type
Original Article
Copyright
2001 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below.

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 45 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 2nd March 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

The repeatability of echocardiographic determination of right ventricular output in the newborn
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

The repeatability of echocardiographic determination of right ventricular output in the newborn
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

The repeatability of echocardiographic determination of right ventricular output in the newborn
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *