Hostname: page-component-7c8c6479df-hgkh8 Total loading time: 0 Render date: 2024-03-29T09:45:48.143Z Has data issue: false hasContentIssue false

Scalp EEG in Temporal Lobe Epilepsy Surgery

Published online by Cambridge University Press:  02 December 2014

Mark Sadler
Affiliation:
Queen Elizabeth II Health Sciences Centre, Halifax, N.S.
Richard Desbiens
Affiliation:
Hôpital, de l'Enfant-Jésus, Quebec City, Quebec
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Electroencephalography (EEG) with standard scalp and additional noninvasive electrodes plays a major role in the selection of patients for temporal lobe epilepsy surgery. Recent studies have provided data supporting the value of interictal and postictal EEG in assessing the site of ictal onset. Scalp ictal rhythms are morphologically complex but at least one pattern (a five cycles/second rhythm maximum at the sphenoidal or anterior temporal electrode) occurs in >50% of patients and has a high predictive value and interobserver reliability for temporal lobe originating seizures. Thorough interictal and ictal scalp EEG evaluation, in conjunction with modern neuroimaging, is sufficient for proceeding to surgery without invasive recordings in some patients. Further studies are required to define the scalp ictal characteristics of mesial vs. lateral temporal lobe epilepsy.

Type
Research Article
Copyright
Copyright © The Canadian Journal of Neurological 2000

References

1. Jasper, H. The ten-twenty electrode system of the International Federation. Electroencephalogr Clin Neurophysiol 1958; 10:371375.Google Scholar
2. Nuwer, MR. Recording electrode site nomenclature. J Clin Neurophysiol 1987;4:121133.CrossRefGoogle ScholarPubMed
3. Silverman, D. The anterior temporal electrode and the ten-twenty system. Electroencephalogr Clin Neurophysiol 1960;12:735737.CrossRefGoogle ScholarPubMed
4. Laxer, KD. Minisphenoidal electrodes in the investigation of seizures. Electroencephalogr Clin Neurophysiol 1984;58:127129.CrossRefGoogle ScholarPubMed
5. Sadler, RM, Goodwin, J. Multiple electrodes for detecting spikes in partial complex seizures. Can J Neurol Sci 1989;16:326329.CrossRefGoogle ScholarPubMed
6. Sperling, MR, Engel, J. EEG from the temporal lobes: a comparison of ear, anterior temporal, and nasopharyngeal electrodes. Ann Neurol 1985;17:510513.CrossRefGoogle ScholarPubMed
7. Sperling, MR, Mendius, JR, Engel, J. Mesial temporal spikes: a simultaneous comparison of sphenoidal, nasopharyngeal, and ear electrodes. Epilepsia;1986:27:8186.CrossRefGoogle Scholar
8. Binnie, CD, Marston, D, Polkey, CE, et al. Distribution of temporal spikes in relation to the sphenoidal electrode. Electroencephalogr Clin Neurophysiol 1989;73:403409.CrossRefGoogle Scholar
9. Kanner, AM, Ramirez, L, Jones, JC. The utility of placing sphenoidal electrodes under the foramen ovale with fluoroscopic guidance. J Clin Neurophysiol 1995;12: 7281.Google ScholarPubMed
10. Morris, HH, Luders, H, Lesser, RP, et al. The value of closely spaced scalp electrodes in the localization of epileptiform foci: a study of 26 patients with complex partial seizures. Electroencephalogr Clin Neurophysiol 1988;70:105109.Google Scholar
11. Wilkus, RJ, Thompson, PM, Vossler, DG. Quantitative comparison of ictal EEG from sphenoidal, minisphenoidal, anterior temporal, and midtemporal electrodes. Epilepsia 1991;32(suppl3):100101.Google Scholar
12. Krauss, GL, Lesser, RP, Fisher, RF, et al. Anterior “cheek” electrodes are comparable to sphenoidal electrodes for the identification of ictal activity. Electroencephalogr Clin Neurophysiol 1992;83:333338.CrossRefGoogle ScholarPubMed
13. Ives, JR, Drislane, FW, Schacter, SC, et al. Comparison of coronal sphenoidal versus anteroposterior temporal montage in the EEG recording of temporal lobe seizures. Electroencephalogr Clin Neurophysiol 1996; 98:417421.CrossRefGoogle ScholarPubMed
14. Klass, D. Electroencephalographic manifestations of complex partial seizures. In: Penry, JK and Daly, DD (Eds), Advances in Neurology. Vol. 11. Complex Partial Seizures and Their Treatment. New York: Raven Press. 1975:113140.Google ScholarPubMed
15. Williamson, PD, French, JA, Thadani, VM, et al. Characteristics of medial temporal lobe epilepsy: II. Interictal and ictal scalp electroencephalography, neuropsychological testing, neuro-imaging, surgical results, and pathology. Ann Neurol 1993;34: 781787.CrossRefGoogle Scholar
16. Sadler, RM, Lemieux, JF, Blume, WT. Potential fields of anterior temporal spikes. Electroencephalogr Clin Neurophysiol 1984;58:P47-P48 (abstract).Google Scholar
17. Marks, DA, Kratz, A, Booke, J, et al. Comparison and correlation of surface and sphenoidal electrodes with simultaneous intracranial recording: an interictal study. Electroencephalogr Clin Neurophysiol 1992;82:2329.CrossRefGoogle ScholarPubMed
18. Baumgartner, C, Lindinger, G, Ebner, A, et al. Propagation of interictal epileptic activity in temporal lobe epilepsy. Neurology 1995;45:118122.CrossRefGoogle ScholarPubMed
19. Sutherling, WW and Barth, DS. Neocortical propagation in temporal lobe spike foci on magnetoencephalography and electroencepha-lography. Ann Neurol 1989;25:373381.CrossRefGoogle Scholar
20. Ebersole, JS. EEG dipole modeling in complex partial epilepsy. Brain Topogr 1993;5:419423.Google Scholar
21. Alarcon, G, Guy, CN, Binnie, CD, et al. Intracerebral propagation of interictal activity in partial epilepsy: implications for source localisation. J Neurol Neurosurg Psychiatry 1994;57:435449.CrossRefGoogle ScholarPubMed
22. Quesney, LF, Risinger, MW, Shewmon, DA. Extracranial EEG evaluation. In: Engel, J. Jr., (ed), Surgical Treatment of the Epilepsies, second edition. New York: Raven Press. 1993: 173195.Google Scholar
23. So, N, Olivier, A, Andermann, F, Gloor, P, Quesney, LF. Results of surgical treatment in patients with bitemporal abnormalities. Ann Neurol 1989;25:432439.CrossRefGoogle ScholarPubMed
24. Chung, MY, Walczak, TS, Lewis, DV, Dawson, DV, Radtke, R. Temporal lobectomy and independent bitemporal interictal activity: what degree of lateralization is sufficient? Epilepsia 1991;32:195201.CrossRefGoogle ScholarPubMed
25. Holmes, MD, Dodrill, CB, Ojemann, GA, Wilensky, AJ, Ojemann, LM. Outcome following surgery in patients with bitemporal interictal epileptiform patterns. Neurology 1997;48:10371040.CrossRefGoogle ScholarPubMed
26. Malow, BA, Kushwaha, R, Lin, X, et al. Relationship of interictal epileptiform discharges to sleep depth in partial epilepsy. Electroencephalogr Clin Neurophysiol 1997;102:2026.CrossRefGoogle ScholarPubMed
27. Sammaritano, M, Gigli, GL, Gotman, J. Interictal spiking during wakefulness and sleep and the localization of foci in temporal lobe epilepsy. Neurology 1991;41:290297.CrossRefGoogle ScholarPubMed
28. Blume, WT, Borghesi, JL, Lemieux, JF. Interictal indices of temporal lobe origin. Ann Neurol 1993;34:703709.CrossRefGoogle Scholar
29. Kanner, A, Morris, H, Luders, H, et al. Usefulness of unilateral interictal sharp waves of temporal lobe origin in prolonged video-EEG monitoring studies. Epilepsia 1993;34:884889.CrossRefGoogle ScholarPubMed
30. Holmes, MD, Dodrill, CB, Wilensky, AJ, et al. Unilateral focal preponderence of interictal epileptiform discharges as a predictor of seizure origin. Arch Neurol 1996;53:228232.CrossRefGoogle Scholar
31. Gabor, AJ and Ajmone-Marsan, C. Co-existence of focal and bilateral d i ffuse paroxysmal discharges in epileptics: a clinical electrographic study. Epilepsia 1969;10:453472.CrossRefGoogle Scholar
32. Sadler, RM and Blume, WT. Significance ofbisynchronous spike-waves in patients with temporal lobe spikes. Epilepsia 1989;30: 143146.CrossRefGoogle ScholarPubMed
33. Reiher, J, Beaudry, M, Leduc, CP. Temporal intermittent rhythmic delta activity (TIRDA) in the diagnosis of complex partial epilepsy: sensitivity, specificity and predictive value. Can J Neurol Sci 1989;16:398401.CrossRefGoogle ScholarPubMed
34. Geyer, JD, Bilir, E, Faught, RE, Kuzniecky, R, Gilliam, F. Significance of interictal temporal lobe delta activity for localization of the primary epileptogenic region. Neurology 1999;52:202205.CrossRefGoogle ScholarPubMed
35. Gambardella, A, Gotman, J, Cendes, F, Andermann, F. Focal intermittent delta activity in patients with mesiotemporal atrophy: a reliable marker of the epileptogenic focus. Epilepsia 1995;36:122129.CrossRefGoogle ScholarPubMed
36. Engel, J. Update on surgical treatment of the epilepsies. Neurology 1993;43:16121617.CrossRefGoogle ScholarPubMed
37. King, D, Spencer, S. Invasive electroencephalography in mesial temporal lobe epilepsy. J Clin Neurophysiol 1995;12:3245.Google ScholarPubMed
38. Lieb, J, Dasheiff, R, Engel, J. Role of the frontal lobes in the propagation of mesial temporal lobe seizures. Epilepsia 1991;32:822837.CrossRefGoogle ScholarPubMed
39. Blume, WT, Young, GB, Lemieux, JF. EEG morphology of partial epileptic seizures. Electroencephalogr Clin Neurophysiol 1984;57:295302.CrossRefGoogle ScholarPubMed
40. Blume, WT, Kaibara, M. The start-stop-start phenomenon of subdurally recorded seizures. Electroencephalogr Clin Neurophysiol 1993;86:9499.CrossRefGoogle ScholarPubMed
41. Atalla, N, Abou-Khalil, B, Fakhoury, T. The start-stop-start phenomenon in scalp-sphenoidal recordings. Electroencephalogr Clin Neurophysiol 1996;98:913.CrossRefGoogle ScholarPubMed
42. Risinger, M, Engel, J, Van Ness, P, et al. Ictal localization of temporal lobe seizures with scalp/sphenoidal recordings. Neurology 1989;39:12881293.CrossRefGoogle ScholarPubMed
43. Walczak, T, Radtke, R, Lewis, D. Accuracy and interobserver reliability of scalp ictal EEG. Neurology 1992;42:22792285.CrossRefGoogle ScholarPubMed
44. Spencer, S, Williamson, P, Bridgers, S, et al. Reliability and accuracy of localization by scalp ictal EEG. Neurology 1985;35:15671575.CrossRefGoogle ScholarPubMed
45. Kaibara, M, Blume, WT. The postictal electroencephalogram. Electroencephalogr Clin Neurophysiol 1988;70:99104.CrossRefGoogle ScholarPubMed
46. Cooper, R, Winter, AL, Crow, HJ, et al. Comparison of subcortical, cortical, and scalp activity using chronic indwelling electrodes in man. Electroencephalogr Clin Neurophysiol 1965;18:217228.CrossRefGoogle ScholarPubMed
47. Lieb, JP, Walsh, GO, Babb, TL. et al. A comparison of EEG seizure patterns recorded with surface and depth electrodes in patients with temporal lobe epilepsy. Epilepsia 1976;17:137160.CrossRefGoogle ScholarPubMed
48. Pacia, SV, Ebersole, JS. Intracranial EEG substrates of scalp ictal patterns from temporal lobe foci. Epilepsia 1997;38:642654.CrossRefGoogle ScholarPubMed
49. Sammaritano, M, de Lotbiniere, A, Andermann, F, et al. False lateralization by surface EEG of seizure onset in patients with temporal lobe epilepsy and gross focal cerebral lesions. Ann Neurol 1987;21:361369.CrossRefGoogle ScholarPubMed
50. Engel, J Jr, Crandall, PH, Brown, WJ. Consistent false lateralization of seizure onset with sphenoidal and scalp telemetred ictal EEG recordings in two patients with partial complex epilepsy. Electroencephalogr Clin Neurophysiol 1980;50:160P(abstract).Google Scholar
51. Sperling, MR, O’Connor, MJ, Saykin, AJ, et al. A noninvasive protocol for anterior temporal lobectomy. Neurology 1992;42:416422.CrossRefGoogle ScholarPubMed
52. Sirven, JI, Liporace, JD, French, JA, et al. Seizures in temporal lobe epilepsy. I. Reliability of scalp sphenoidal ictal recording. Neurology 1997;48:10411046.CrossRefGoogle ScholarPubMed
53. Blum, D. Prevalence of bilateral partial seizure foci and implications for electroencephalographic telemetry monitoring and epilepsy surgery. ElectroencephalogrClinNeurophysiol 1994;91:329336.Google ScholarPubMed
54. Haut, SR, Legatt, AD, O’Dell, C, et al. Seizure lateralization during EEG monitoring in patients with bilateral foci: the cluster effect. Epilepsia 1997;38:937940.CrossRefGoogle ScholarPubMed