Abstract

Background: Diffusion-tensor imaging (DTI) tractography is commonly used in neurosurgical practice, but is largely limited to the preoperative setting. This is due primarily to image degradation caused by susceptibility artifact when conventional single-shot (SS) echo-planar imaging DTI is acquired for open cranial, surgical position intraoperative DTI (iDTI). A novel, artifact-resistant, readout-segmented (RS) DTI has not yet been evaluated in the intraoperative MRI (iMRI) environment. Our objective was to evaluate the performance of RS-DTI versus SS-DTI for intraoperative white matter imaging. Methods: Pre- and intraoperative 3T, T1-weighted and DTI (RS-iDTI and SS-iDTI) in 22 adults undergoing intraaxial iMRI resections (low-grade glioma: 14, 64%; high-grade glioma: 7, 32%; cortical dysplasia: 1). Regional susceptibility artifact, anatomical deviation relative to T1WI, and tractographic output were compared between iDTI sequences. Results: RS-iDTI resulted in less regional susceptibility artifact and mean anatomic deviation (RS-iDTI: 2.7±0.2 mm versus SS-iDTI 7.5±0.4 mm; p<0.0001). Tractographic failure occurred in 8/22 (36%) patients for SS-iDTI whereas RS-iDTI permitted successful reconstruction in 4 of these 8. Maximal tractographic differences between DTI sequences were substantial (mean 9.7±5.7 mm). Conclusions: Readout-segmented EPI enables higher quality and more accurate DTI for surgically relevant tractography of major white matter tracts in intraoperative, open cranium, neurosurgical applications at 3T.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      GP.05 Intraoperative acquisition of diffusion tensor imaging in cranial neurosurgery: readout-segmented DTI versus standard single-shot DTI
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      GP.05 Intraoperative acquisition of diffusion tensor imaging in cranial neurosurgery: readout-segmented DTI versus standard single-shot DTI
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      GP.05 Intraoperative acquisition of diffusion tensor imaging in cranial neurosurgery: readout-segmented DTI versus standard single-shot DTI
      Available formats
      ×

Copyright

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed