Skip to main content Accessibility help
×
Hostname: page-component-76fb5796d-x4r87 Total loading time: 0 Render date: 2024-04-26T17:43:28.114Z Has data issue: false hasContentIssue false

12 - Windows on the working brain: evoked potentials, magnetencephalography and depth recording

from PART I - INTRODUCTION AND GENERAL PRINCIPLES

Published online by Cambridge University Press:  05 August 2016

Hans-Joachim Freund
Affiliation:
University of Dusseldorf Neurology Clinic, Germany
Hans J. Heinze
Affiliation:
University of Magdeburg, Germany
Arthur K. Asbury
Affiliation:
University of Pennsylvania School of Medicine
Guy M. McKhann
Affiliation:
The Johns Hopkins University School of Medicine
W. Ian McDonald
Affiliation:
University College London
Peter J. Goadsby
Affiliation:
University College London
Justin C. McArthur
Affiliation:
The Johns Hopkins University School of Medicine
Get access

Summary

A number of techniques have been developed for the study of human brain functions in normal and disordered states. Each of them monitors function from a selective point of view. Whereas functional imaging techniques are based on neurovascular coupling (functional magnetic resonance imaging (fMRI), positron emission tomography (PET), nearinfrared spectroscopy (NIRS) and optical imaging), electrophysiological methods directly reflect neuronal activity. Electroencephalography (EEG) and magnetencephalography (MEG) provide information about global as well as regional activity under stationary conditions or for evoked or event related responses. Subdural or epicortical recordings for the identification of epileptogenic foci and microelectrode recordings for functional target identification during stereotactic neurosurgery complement the spectrum of the clinical application of neurophysiological tools.

Taken together, the neurovascular and neurophysiological methods provide largely complementary information that allows better insights in normal and disturbed brain function. The superimposition of MEG data on MR images combines the high spatial and temporal resolution of the respective methods. EEG recordings can now be conducted inside the MR scanner allowing the recognition of epileptogenic foci during EEG-defined seizure episodes.

Towards an integrative MEG and EEG study of cognitive brain functions

EEG and MEG measures arise from the same cortical source, namely from ordered intracellular currents in the pyramidal cells (Okada, 1982). Since the pyramidal cells in a circumscribed area show basically the same orientation orthogonal to the surface, the superimposed neural currents may result in macroscopically measurable electromagnetic fields. The electric and magnetic fields have orthogonal orientation and bear formally equivalent information; however, it may well be that stimulus-triggered event related potentials (ERPs) or magnetic fields (MFs) reveal different aspects of the underlying neural sources depending, for example on the nature of the task and the anatomy of the cortical region of interest. For several reasons, source estimation based on MFs is often superior to ERP based fits. First, opposite to electrical currents MF remain almost unchanged when passing through anatomical structures between the cortex and the sensor sets. Hence, the MFs are less susceptible to inadequate head models, both regarding anatomical shape and tissue conductivities (CSF space, scull, scalp). Secondly, the superficially observed MF originate from the primary neuronal currents (i.e. currents inside the dendrites) whereas volume currents do not contribute for physical reasons. In contrast, ERPs reflect both primary and volume currents.

Type
Chapter
Information
Diseases of the Nervous System
Clinical Neuroscience and Therapeutic Principles
, pp. 160 - 174
Publisher: Cambridge University Press
Print publication year: 2002

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×