Hostname: page-component-6d856f89d9-4thr5 Total loading time: 0 Render date: 2024-07-16T07:13:46.970Z Has data issue: false hasContentIssue false

Effect of pulsed excimer laser irradiation on the magnetic anisotropy of iron-base and nickel-iron-base metallic glasses

Published online by Cambridge University Press:  03 March 2011

M. Sorescu
Affiliation:
Department of Chemistry and the University Center for Laser Research, Oklahoma State University, Stillwater, Oklahoma 74078-0447
E.T. Knobbe
Affiliation:
Department of Chemistry and the University Center for Laser Research, Oklahoma State University, Stillwater, Oklahoma 74078-0447
Get access

Abstract

The present work has examined the effect of pulsed excimer laser irradiation (λ = 308 nm, τ = 26 ns, E = 100 mJ/pulse, N = 1, 5, 10 laser pulses/spot, repetition rate 1 Hz) on the magnetic anisotropy of Fe81B13.5Si3.5C2, Fe78B13Si9, Fe40Ni38Mo4B18, and Fe40Ni40P14B6 metallic glasses. The transmission Mössbauer spectra yielded the intensity ratio R21 of the second to the first line as a function of the number of applied laser pulses. On these grounds, it was found that in the higher magnetostriction samples, controlled changes in the magnetic anisotropy could be induced without onset of bulk crystallization; in the lower magnetostriction samples, a random distribution of the magnetic moment directions was obtained. The conversion electron Mössbauer spectra were characteristic of the amorphous state but showed the same texture as the nonirradiated samples. SEM examinations of the laser-treated surfaces revealed the presence of molten zones subsequently solidified. It is suggested that the correspondingly induced stresses may account for the observed changes in the bulk magnetization orientation, and the model of closure domain structure is supported.

Type
Articles
Copyright
Copyright © Materials Research Society 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1Metglas Technical Bulletin, Allied-Signal Inc. (1992).Google Scholar
2Koch, C. C., Kroeger, D. M., Lin, J. S., Scarbrough, J. O., Johnson, W. L., and Anderson, A. C., Phys. Rev. B 27, 1586 (1983).CrossRefGoogle Scholar
3Egami, T., J. Magn. Magn. Mater. 31–34, 1571 (1983).CrossRefGoogle Scholar
4Lanotte, L., Luponio, C., and Porreca, F., II Nuovo Cimento 9D 6, 633 (1987).CrossRefGoogle Scholar
5Matteazi, P., Lanotte, L., and Tagliaferri, V., Hyp. Int. 45, 315 (1989).CrossRefGoogle Scholar
6Sorescu, D., Sorescu, M., Mihailescu, I. N., Barb, D., and Hening, A., Solid State Commun. 85, 717 (1993).CrossRefGoogle Scholar
7Schurer, P. J. and Morrish, A. H., J. Magn. Magn. Mater. 15–18, 577 (1980).Google Scholar
8Randrianantoandro, N., Greneche, J. M., and Varret, F., J. Magn. Magn. Mater. 117, 93 (1992).CrossRefGoogle Scholar
9Herzer, G. and Hilzinger, H. R., J. Magn. Magn. Mater. 62, 143 (1986).Google Scholar
10Barb, F. D., Netoiu, O., Sorescu, M., and Weiss, M., Computer Phys. Commun. 69, 182 (1992).CrossRefGoogle Scholar
11Spijkerman, J. J., in Mossbauer Effect Methodology, edited by Gruverman, I. J. (Plenum, New York-London, 1971), Vol. 7, p. 85.CrossRefGoogle Scholar
12Sanchez, P., Sanchez, M. C., Lopez, E., Garcia, M., and Aroca, C., J. Phys. (Paris) 12, 49 (1988).Google Scholar
13Lanotte, L., Matteazzi, P., and Tagliaferri, V., J. Magn. Magn. Mater. 42, 183 (1984).CrossRefGoogle Scholar
14Stenger, S., Sorescu, M., and Gonser, U., J. Non-Cryst. Solids 151, 66 (1992).CrossRefGoogle Scholar
15Ok, H. N. and Morrish, A. H., Phys. Rev. B 23, 2257 (1981).CrossRefGoogle Scholar
16Schaaf, P., Kramer, A., Blaes, L., Wagner, G., Aubertin, F., and Gonser, U., Nucl. Instrum. Methods Phys. Res. B 53, 184 (1991).CrossRefGoogle Scholar