Skip to main content Accessibility help
×
Home
Hostname: page-component-544b6db54f-zts5g Total loading time: 0.167 Render date: 2021-10-16T00:05:48.642Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true, "newUsageEvents": true }

Effects of electron beam irradiation on time to clear vision of misted dental mirror glass

Published online by Cambridge University Press:  31 January 2011

Kazuya Oguri
Affiliation:
Department of Physics, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Katsuhiro Fujita
Affiliation:
Graduate students of Materials Science, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Motoi Takahashi
Affiliation:
Graduate students of Materials Science, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Yuji Omori
Affiliation:
Graduate students of Materials Science, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Akira Tonegawa
Affiliation:
Department of Physics, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Naosige Honda
Affiliation:
Graduate student of Materials Science, Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Masafumi Ochi
Affiliation:
Iwasaki Electric Group Company, 1–1 Ichirisatoyamachou, Gyouda, Saitama 361, Japan
Kazuo Takayama
Affiliation:
Honorary Professor of Tokai University, 1117 Kitakaname, Hiratsuka, Kanagawa 259–12, Japan
Yoshitake Nishi
Affiliation:
Department of Materials Science, Tokai University, 1117 Kitakaname Hiratsuka, Kanagawa 259–12, Japan
Get access

Extract

A misting free dental mirror is obtained near the human temperature under the saturated humidity atmosphere by use of the sheet electron beam irradiation treatment. It is shown that electron beam irradiation treatment decreases the time to clear vision in a misted mirror. This effect is due to an enhancement of the interfacial energy between the dental mirror glass and water.

Type
Articles
Copyright
Copyright © Materials Research Society 1998

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Inoue, N., Kikuchi, M., Manabe, T., Shima, T., and Nishi, Y., Nucl. Instrum. Methods B 59/60, 1328 (1991).Google Scholar
2.Inoue, N., Kikuchi, M., Shima, T., Iwase, M., and Nishi, Y., Phys. Lett. A 157, 299 (1991).CrossRefGoogle Scholar
3.Nishi, Y., Takagi, S., Yasuda, K., and Itoh, K., J. Appl. Phys. 70, 367 (1991).CrossRefGoogle Scholar
4.Nishi, Y., Takagi, S., Yasuda, K., Itoh, K., and Kawakami, M., Nucl. Instrum. Methods B 59/60, 1422 (1991).CrossRefGoogle Scholar
5.Nishi, Y., Takahashi, Y., Takagi, S., Sudo, T., Inoue, N., and Shima, T., Phys. Rev. B 41, 541 (1992).Google Scholar
6.Johnson, W. A. and Mehl, R. F., Trans. A.I.M.E. 35, 416 (1991).Google Scholar
7.Nishi, Y. and Harano, H., J. Appl. Phys. 63, 1141 (1988).CrossRefGoogle Scholar
8.Nishi, Y., Harano, H., Fukunaga, T., and Suzuki, K., Phys. Rev. B 37, 2855 (1988).CrossRefGoogle Scholar
9.Turnbull, D. and Fisher, J. D., J. Chem. Phys. 17, 71 (1949).CrossRefGoogle Scholar

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Effects of electron beam irradiation on time to clear vision of misted dental mirror glass
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Effects of electron beam irradiation on time to clear vision of misted dental mirror glass
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Effects of electron beam irradiation on time to clear vision of misted dental mirror glass
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *