Skip to main content Accessibility help
×
Hostname: page-component-848d4c4894-4hhp2 Total loading time: 0 Render date: 2024-05-07T05:30:19.342Z Has data issue: false hasContentIssue false

Chapter 24 - Safe care of the fetus

from Section 3 - Proactive support of labor

Published online by Cambridge University Press:  05 September 2015

Paul Reuwer
Affiliation:
Department of Obstetrics, St Elisabeth Hospital, Tilburg
Hein Bruinse
Affiliation:
Department of Obstetrics and Gynecology, Utrecht University Medical Center
Arie Franx
Affiliation:
Department of Obstetrics, St Elisabeth Hospital, Tilburg
Get access

Summary

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Chapter
Information
Proactive Support of Labor
The Challenge of Normal Childbirth
, pp. 166 - 177
Publisher: Cambridge University Press
Print publication year: 2015

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Ugwumadu, A. Understanding cardiotocographic patterns associated with intrapartum fetal hypoxia and neurologic injury. Best Practice Res Clin Obst Gynaecol 2013;27:509–36Google ScholarPubMed
Tucker Blackburn, S. Maternal, Fetal and Neonatal Physiology: A Clinical Perspective, 3rd revised edition. Saunders; 2007Google Scholar
Ugwumadu, A. Are we (mis)guided by current guidelines on intrapartum fetal heart rate monitoring? Case for a more physiological approach to interpretation. Br J Obstet Gynaecol 2014;121:1063–70Google Scholar
Hankins, GD, Speer, M. Defining the pathogenesis and pathophysiology of neonatal encephalopathy and cerebral palsy. Obstet Gynecol 2003;102:628–36Google Scholar
ACOG Committee Opinion no. 348, November 2006: Umbilical cord gas and acid-base analysis. Obstet Gynecol 2006;108:1319–22Google Scholar
Hankins, GD, MacLennan, AH, Speer, ME, Strunk, A, Nelson, K. Obstetric litigation is asphyxiating our maternity services. Obstet Gynecol 2006;107:1382–5Google Scholar
Macones, GA, Hankins, GD, Spong, CY, Hauth, J, Moore, T. The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines. Obstet Gynecol 2008;112: 661–6Google Scholar
National Institute of Clinical Excellence. Intrapartum Care: Care of Healthy Women and Their Babies During Labour. NICE Clinical Guideline No. 55. National Collaborating Centre for Women’s and Children’s Health London, UK: RCOG Press, 2007Google Scholar
American College of Obstetricians and Gynecologists. Practice bulletin no. 116: management of intrapartum fetal heart rate tracings. Obstet Gynecol 2010;116:1232–40Google Scholar
Jackson, M, Holmgren, CM, Esplin, MS, Henry, E, Varner, MW. Frequency of fetal heart rate categories and short-term neonatal outcome. Obstet Gynecol 2011;118:803–8Google Scholar
Blackwell, SC, Grobman, WA, Antoniewicz, L, Hutchinson, M, Gyamfi Bannerman, C. Interobserver and intraobserver reliability of the NICHD 3-Tier Fetal Heart Rate Interpretation System. Am J Obstet Gynecol 2011;205:378.e1–5. Epub 2011 June 29.Google Scholar
NICE Guidelines. Intrapartum care: care of healthy women and their babies during childbirth. RCOG Press; 2007. Updated 2010 www.nice.org.uk/guidance/cg55Google Scholar
Melchior, J, Bernhard, N. Incidence and pattern of fetal heart rate alterations during labor. In Kunzel, W, ed. Fetal Heart Rate Monitoring: Clinical Practice and Pathophysiology. Berlin: Springer; 1985:73.CrossRefGoogle Scholar
Walker, J. Foetal anoxia. J Obstet Gynaecol Br Commonw 1953;61:162–80Google Scholar
Ahanya, SN, Lakshmanan, J, Morgan, BL, Ross, MG. Meconium passage in utero: mechanisms, consequences, and management. Obstet Gynecol Surv 2005;60:4556Google Scholar
Nathan, L, Leveno, KJ, Carmody, TJ, Kelly, MA, Sherman, LM. Meconium: a 1990s perspective on an old obstetric hazard. Obstet Gynecol 1994;83:329–32.Google Scholar
Ramin, KD, Leveno, KJ, Kelly, MA, Carmody, TJ. Amniotic fluid meconium: a fetal environmental hazard. Obstet Gynecol 1996;87:181–4Google Scholar
Garcia-Prats, JA. Clinical features and diagnosis of meconium aspiration syndrome. UpToDate. Accessed November 2014Google Scholar
Ghidini, A, Spong, CY. Severe meconium aspiration syndrome is not caused by aspiration of meconium. Am J Obstet Gynecol 2001;185:931–8Google Scholar
Blackwell, SC, Moldenhauer, J, Hassan, SS, et al. Meconium aspiration syndrome in term neonates with normal acid-base status at delivery: is it different? Am J Obstet Gynecol 2001;184:1422–5; discussion 1425–6Google Scholar
Dollberg, S, Livny, S, Mordecheyev, N, Mimouni, FB. Nucleated red blood cells in meconium aspiration syndrome. Obstet Gynecol 2001;97:593–6Google Scholar
Jazayeri, A, Politz, L, Tsibris, JC, Queen, T, Spellacy, WN. Fetal erythropoietin levels in pregnancies complicated by meconium passage: does meconium suggest fetal hypoxia? Am J Obstet Gynecol 2000;183:188–90Google Scholar
Vintzileos, AM, Nochimson, DJ, Guzman, ER, et al. Intrapartum electronic fetal heart rate monitoring versus intermittent auscultation: a meta-analysis. Obstet Gynecol 1995;85:149–55Google Scholar
Thacker, SB, Stroup, DF, Peterson, HB. Efficacy and safety of intrapartum electronic fetal monitoring: an update. Obstet Gynecol 1995;86:613–20Google Scholar
Nelson, KB, Dambrosia, JM, Ting, TY, Grether, JK. Uncertain value of electronic fetal monitoring in predicting cerebral palsy. N Engl J Med 1996;334:613–18Google Scholar
Parer, JT, King, T. Fetal heart rate monitoring: is it salvageable? Am J Obstet Gynecol 2000;182:982–7Google Scholar
Young, BK. Intrapartum fetal heart rate assessment. UpToDate. Accessed November 2014Google Scholar
Devane, D, Lalor, JG, Daly, S, McGuire, W, Smith, V. Cardiotocography versus intermittent auscultation of fetal heart on admission to labour ward for assessment of fetal wellbeing. Cochrane Database Syst Rev 2012Google Scholar
American College of Obstetricians and Gynecologists. Fetal Heart Rate Patterns: Monitoring, Interpretations, and Management. Technical Bulletin No. 207. July 1995Google Scholar
Royal College of Obstetricians and Gynaecologists. The Use of Electronic Fetal Monitoring: The Use and Interpretation of Cardiotocography in Intrapartum Surveillance. London: Royal College of Obstetricians and Gynaecologists; 2001Google Scholar
Greenwood, C, Lalchandini, S, MacQuillan, K, et al. Meconium passed in labor: How reassuring is clear amniotic fluid? Obstet Gynecol 2003;102:8993Google ScholarPubMed
Grant, A. Monitoring the fetus during labour. In: Chalmers, I, Keirse, MJNC, Enkin, M, eds. Effective Care in Pregnancy and Childbirth, Vol 2. Oxford: Oxford University Press; 1989Google Scholar
Jørgensen, JS, Weber, T. Fetal scalp blood sampling in labor: a review. Acta Obstet Gynecol Scand 2014;93:548–55Google Scholar
Reif, P, Haas, J, Schöll, W, Lang, U. [Foetal scalp blood sampling: impact on the incidence of Caesarean section and assisted vaginal deliveries for non-reassuring foetal heart rate and its use according to gestational age]. Z Geburtshilfe Neonatol 2011;215:194–8Google Scholar
Alfirevic, Z, Devane, D, Gyte, GM. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. Cochrane Database Syst Rev 2013CrossRefGoogle Scholar
Chauhan, SP, Magann, EF, Scott, JR, et al. Emergency cesarean delivery for nonreassuring fetal heart rate tracings: compliance with ACOG guidelines. J Reprod Med 2003;48:975–81Google Scholar
Westgren, M, Kruger, K, Ek, S, et al. Lactate compared with pH analysis at fetal scalp blood sampling: a prospective randomized study. Br J Obstet Gynaecol 1998;105:2933Google Scholar
Kruger, K, Hallberg, B, Blennow, M, Kublickas, M, Westgren, M. Predictive value of fetal scalp blood lactate concentration and pH as markers of neurologic disability. Am J Obstet Gynecol 1999;181:1072–8CrossRefGoogle ScholarPubMed
East, CE, Leader, LR, Sheehan, P, Henshall, NE, Colditz, PB. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 2010Google Scholar
Garite, TJ, Dildy, GA, McNamara, H, et al. A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. Am J Obstet Gynecol 2000;183:1049–58Google Scholar
Klauser, CK, Christensen, EE, Chauhan, SP, et al. Use of fetal pulse oximetry among high-risk women in labor: a randomized clinical trial. Am J Obstet Gynecol 2005;192:1810–7Google Scholar
East, CE, Brennecke, SP, King, JF, et al. The effect of intrapartum fetal pulse oximetry, in the presence of a nonreassuring fetal heart rate pattern, on operative delivery rates: a multicenter, randomized, controlled trial (the FOREMOST trial). Am J Obstet Gynecol 2006;194:606.e1–16Google Scholar
Bloom, SL, Spong, CY, Thom, E, et al. (National Institute of Child Health and Human Development Maternal-Fetal Medicine Units Network). Fetal pulse oximetry and cesarean delivery. N Engl J Med 2006;355:2195–202Google Scholar
Olofsson, P, Ayres-de-Campos, D, Kessler, J, et al. A critical appraisal of the evidence for using cardiotocography plus ECG ST interval analysis for fetal surveillance in labor. Part II: the meta-analyses. Acta Obstet Gynecol Scand 2014;93:571–86Google Scholar
Macones, G. Management of intrapartum category I, II, and III fetal heart rate tracings. UpToDate. Accessed November 2014.Google Scholar
Hofmeyr, GJ, Lawrie, TA. Amnioinfusion for potential or suspected umbilical cord compression in labour. Cochrane Database Syst Rev 2012Google Scholar
Hendrix, NW, Chauhan, SP. Cesarean delivery for nonreassuring fetal heart rate tracing. Obstet Gynecol Clin N Am 2005; 32: 273–86.Google Scholar
Kulier, R, Hofmeyr, JG. Tocolytics for suspected intrapartum fetal distress. Cochrane Database Syst Rev 2006Google Scholar
Draper, ES, Kurinczuk, JJ, Lamming, CR, et al. A confidential enquiry into cases of neonatal encephalopathy. Arch Dis Child Fetal Neonatal Ed 2002;87(3):176–80Google Scholar
Dupont, C, Touzet, S, Rudigoz, RC, et al. Critical events in obstetrics: a confidential enquiry in four high-level maternities of the AURORE perinatal network. Journal of Evaluation in Clinical Practice 2008;14:165–68Google Scholar
Papworth, S, Cartlidge, P. Learning from adverse events – the role of confidential enquiries. Semin Fetal Neonatal Med 2005;10:3943Google Scholar
Liston, R, Crane, J, Hamilton, E, et al. Fetal health surveillance in labour. J Obstet Gynaecol Can 2002;24:250–76Google ScholarPubMed
Rosser, J. Confidential Enquiry into Stillbirths and Deaths in Infancy (CESDI). Highlights of the 6th annual report. Pract Midwife 1999;2:819Google Scholar
Maternal and Child Health Research Consortium. 8th Annual Report. Confidential enquiry into stillbirths and deaths in infancy. London: Elsevier; 2001Google Scholar
Young, P, Hamilton, R, Hodgett, S, et al. Reducing risk by improving standards of intrapartum fetal care. J R Soc Med 2001;94:226–31Google Scholar
O’Mahony, F, Settatree, R, Platt, C, Johanson, R. Review of singleton fetal and neonatal deaths associated with cranial trauma and cephalic delivery during a national intrapartum-related confidential enquiry. Br J Obstet Gynaecol 2005;112:619–26Google Scholar
Tan, KH, Wyldes, MP, Settatree, R, Mitchell, T. Confidential regional enquiry into mature stillbirths and neonatal deaths: a multi-disciplinary peer panel perspective of the perinatal care of 238 deaths. Singapore Med J 1999;40:251–5Google ScholarPubMed
Liston, R, Sawchuck, D, Young, D; Society of Obstetrics and Gynaecologists of Canada; British Columbia Perinatal Health Program. Fetal health surveillance: antepartum and intrapartum consensus guideline. J Obstet Gynaecol Can 2007;29:S356Google Scholar
Maternal and Child Health Research Consortium. Confidential enquiry into stillbirths and deaths in infancy: 4th Annual Report, 1 January–31 December 1995Google Scholar
RCOG. Confidential enquiry into maternal and child health maternity services in 2002 for women with type 1 and type 2 diabetes. London: RCOG Press; 2004Google Scholar

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×