Imaging description

Ultrasound is the initial study of choice for the evaluation of suspected ovarian torsion, due to its ability to evaluate the structure and size of the adnexa without ionizing radiation, and its ability to evaluate vascular flow.

It is erroneous to assume that the presence of Doppler flow excludes ovarian torsion and the absence of flow confirms torsion; evaluation is more complex and subtle than this simple binary approach would suggest.

Overall, there are quite variable data supporting the accuracy of ultrasound for the preoperative diagnosis of ovarian torsion: correct preoperative diagnostic rates have been reported to be as low as 23–66% of cases [1]. Absence of both arterial and venous flow in an enlarged ovary is highly suggestive of ovarian torsion, with a sensitivity approaching 100% and a specificity of 97% [2], while normal flow in a normal-sized and normal-appearing ovary is extremely unlikely to represent torsion. However, arterial or venous flow may occur in an ovary that has undergone torsion. In one series of 199 patients who presented with adnexal pain, 29 of whom had surgically proven ovarian torsion, the absence of Doppler flow in the ovarian artery was noted in only 22 (76%), although there was abnormal (non-continuous) or absent flow in the ovarian vein in 29 (100%) [2]. Our local experience demonstrates the presence of normal arterial and continuous venous flow does not entirely exclude torsion. An enlarged ovary with clinical symptoms of torsion may in fact have undergone torsion, either currently, or intermittently in the past, even if Doppler flow is demonstrated (Figure 74.1) [1, 3]. Other signs such as visible coiling of the ovarian pedicle (the “whirlpool sign”) have been reported to reliably predict ovarian torsion [4].

Type
Chapter
Information
Pearls and Pitfalls in Emergency Radiology
Variants and Other Difficult Diagnoses
, pp. 248 - 249
Publisher: Cambridge University Press
Print publication year: 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Mashiach, R, Melamed, N, Gilad, N, Ben-Shitrit, G, Meizner, I.Sonographic diagnosis of ovarian torsion: accuracy and predictive factors. J Ultrasound Med. 2011;30(9):1205–10.CrossRefGoogle ScholarPubMed
Nizar, K, Deutsch, M, Filmer, S, et al. Doppler studies of the ovarian venous blood flow in the diagnosis of adnexal torsion. J Clin Ultrasound. 2009;37(8):436–9.CrossRefGoogle Scholar
Shadinger, LL, Andreotti, RF, Kurian, RL.Preoperative sonographic and clinical characteristics as predictors of ovarian torsion. J Ultrasound Med. 2008;27(1):7–13.CrossRefGoogle ScholarPubMed
Auslender, R, Shen, O, Kaufman, Y, et al. Doppler and gray-scale sonographic classification of adnexal torsion. Ultrasound Obstet Gynecol. 2009;34(2):208–11.CrossRefGoogle ScholarPubMed
Schultz, LR, Newton, WA., Clatworthy, HW. Torsion of previously normal tube and ovary in children. N Engl J Med. 1963;268:343–6.CrossRefGoogle ScholarPubMed
Chang, HC, Bhatt, S, Dogra, VS. Pearls and pitfalls in diagnosis of ovarian torsion. Radiographics. 2008;28(5):1355–68.CrossRefGoogle ScholarPubMed

Save book to Kindle

To save this book to your Kindle, first ensure coreplatform@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×