Hostname: page-component-76fb5796d-zzh7m Total loading time: 0 Render date: 2024-04-26T23:04:08.603Z Has data issue: false hasContentIssue false

Non destructive testing of works of art by terahertz analysis

Published online by Cambridge University Press:  15 November 2013

Jean-Luc Bodnar*
Affiliation:
GRESPI/ ECATHERM, UFR Sciences Exactes et Naturelles, BP 1039, 51687 Reims, France
Jean-Jacques Metayer
Affiliation:
VISIOM, Parc de haute Technologie, 13 rue Alexis de Tocqueville, SILIC 41, 92182 Antony, France
Kamel Mouhoubi
Affiliation:
GRESPI/ ECATHERM, UFR Sciences Exactes et Naturelles, BP 1039, 51687 Reims, France
Vincent Detalle
Affiliation:
LRMH, 29 avenue du Paris, 77420 Champs-sur-Marne, France
Get access

Abstract

Improvements in technologies and the growing security needs in airport terminals lead to the development of non destructive testing devices using terahertz waves. Indeed, these waves have the advantage of being, on one hand, relatively penetrating. They also have the asset of not being ionizing. It is thus potentially an interesting contribution in the non destructive testing field. With the help of the VISIOM Company, the possibilities of this new industrial analysis method in assisting the restoration of works of art were then approached. The results obtained within this framework are presented here and compared with those obtained by infrared thermography. The results obtained show first that the THZ method, like the stimulated infrared thermography allows the detection of delamination located in murals paintings or in marquetries. They show then that the THZ method seems to allow detecting defects located relatively deeply (10 mm) and defects potentially concealed by other defects. It is an advantage compared to the stimulated infra-red thermography which does not make it possible to obtain these results. Furthermore, they show that the method does not seem sensitive to the various pigments constituting the pictorial layer, to the presence of a layer of “Japan paper” and to the presence of a layer of whitewash. It is not the case of the stimulated infrared thermography. It is another advantage of the THZ method. Finally, they show that the THZ method is limited in the detection of low-size defects. It is a disadvantage compared to the stimulated infrared thermography.

Type
Research Article
Copyright
© EDP Sciences, 2013

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Mounaix, P., Pour la science 389, 26 (2010)
Oliveira, F., Barat, R., Schulkin, B., Huang, F., Federici, J.F., Gary, D., Zimdars, D., Proc. SPIE 5411: Terahertz for Military and Security Applications II, 45 (2004), DOI: 10.1117/12.542648
Raimondo, N., Gavalli, M., Xu, Q., Scopigno, R., Terahertz imaging and non disruptive inspection: A practical case, in IRMMW – THZ, 2011 Google Scholar
Kawase, K., Ogawa, Y., Watanabe, Y., Optic Express 11, 2549 (2003)CrossRef
Zimdars, D., White, J.S., Stuk, G., Chernovsky, A., Fichter, G., Williamson, S., Insight 48, 537 (2006)CrossRef
Jansen, C., Wietzke, S., Peters, O., Scheller, M., Vieweg, N., Salhi, M., Krumboltz, N., Jordens, C., Hochrein, T., Koch, M., Appl. Opt. 49, 48 (2010)CrossRef
Jackson, J.B., Mourou, M., Whitaker, J.F., Duling, I.N., Williamson, S.L., Menu, M., Mourou, G.A., Opt. Commun. 281, 527 (2008)CrossRef
Jackson, J.B., Mourou, M.R., Whitaker, J.F., Duling, I.N., Terahertz time domain reflectometry applied to the investigation of hidden mural paintings, in Laser and Electrooptics, pp. 12, ISBN: 978-1-55752-859-9
Jackson, J.B., Labaune, J., Mourou, G., Duling, I.N., Walker, G., Bowen, J., Menu, M., in proc SPIE 8084: Optics for Arts, Architecture and Archaeology, Munich, Germany, 2011, DOI: 10.1117/12.888730
Jackson, J.B., PhD, University of Michigan, 2008
Abraham, E., Younus, A., Delagnes, J.C., Mounaix, P., Appl. Phys. A 100, 585 (2010)CrossRef
Fukunaga, K., Sekine, N., Hosako, I., Oda, N., Yoneyama, H., Sudoh, T., J. Eur. Opt. Soc. Rapid Publ. 3, 08027 (2008)CrossRef
Fukunaga, K., THZ technology applied to culture heritage, in Infrared, Millimetre and Terahertz Waves, 2012, pp. 14, ISBN: 978-1-4673-1598-2 Google Scholar
Bacci, M., Exploitation of the whole electromagnetic spectrum in art conservation studies, in Infrared, Millimetre and Terahertz Waves, 2010, pp. 14, ISBN: 978-1-4244-6655-9 Google Scholar
Fukunaga, K., Picollo, M., in Characterization of Work of Art, Spectrometry and Imaging, Optical Sciences, Springer Series in Optical Sciences, vol. 171 (2013) pp. 521538 Google Scholar
Labaume, J., Jackson, J.B., Fukunaga, K., White, J., Appl. Phys. A 105, 5 (2011)CrossRef
Abraham, E., Younus, A., el Fatiy, A., Delagnes, J.C., Nguema, E., Mounaix, P., Opt. Commun. 282, 3104 (2009)CrossRef
Köhler, W., Panzer, M., Klotzach, U., Winner, S., Helm, M., Rutz, F., Jordens, C., Koch, M., Leitner, H., non destructive investigation of paintings with THZ radiations, in European conference on non destructive testing, Berlin, 2006 Google Scholar
Szantanik, G., Étude et restauration d’une peinture murale représentant le Saint Christophe : mise en œuvre de la radiométrie photothermique pour l’examen du support, INP, Sept. 2004
Szatanik, G., Gerard, M., Bodnar, J.L., Journal de Conservation et restauration (coré) 64 (2006)
Candoré, J.C., Détection et caractérisation de défauts par thermographie infrarouge stimulée: Application au contrôle d’œuvres d’art, PhD, Reims, 0June 2010 Google Scholar
Candoré, J.C., Bodnar, J.L., Detalle, V., Grossel, P., Eur. Phys. J. Appl. Phys. 57, 21002 (2012)CrossRef
Bodnar, J.L., Candoré, J.C., Nicolas, J.L., Szatanik, G., Detalle, V., Vallet, J.M., NDT & E International 49, 40 (2012)CrossRef
Bodnar, J.L., Mouhoubi, K., Szatanik-Perrier, G., Vallet, J.M., Detalle, V., Int. J. Thermophys. 33, 1996 (2012)CrossRef
Tornari, V., Bernikola, E., Tsiranidou, E., Hatzigiannakis, K., Andrianakis, M., Detalle, V., Bodnar, J.L., Int. J. Herit. Digit. Era 2 (2013)