Hostname: page-component-7479d7b7d-767nl Total loading time: 0 Render date: 2024-07-11T10:34:46.487Z Has data issue: false hasContentIssue false

Presentation of the CERES platform used to evaluate the consequences of the emissions of pollutants in the environment

Published online by Cambridge University Press:  09 January 2012

M. Monfort
Affiliation:
CEA, DAM, DIF, 91297 Arpajon, France
L. Patryl
Affiliation:
CEA, DAM, DIF, 91297 Arpajon, France
P. Armand
Affiliation:
CEA, DAM, DIF, 91297 Arpajon, France
Get access

Abstract

The CERES application (Code d’Evaluations Rapides Environnementales et Sanitaires) has been developed by CEA. It is used to evaluate the consequences on human health of releases of isotopes in the environment, either for emergency planning or for safety evaluation. Various types of emissions can be simulated: atmospheric accidental emission, atmospheric emission during normal operation or emission in liquid media under normal operation. Two versions exist, one devoted to radiological impact, the other one devoted to toxic impact.

Type
Research Article
Copyright
© Owned by the authors, published by EDP Sciences, 2011

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Monfort, M., 2008: Description des modèles e la suite de codes MITHRA-EA destinée à l’évaluation de la dispersion atmosphérique et des conséquences radiologiques de rejets accidentels de radionucléides. Note Technique. Technical Document.
Doury, A. 1981: Le vademecum des transferts atmosphériques. Rapport DSN 440.
Briggs, G.A., 1973: Diffusion estimation for small estimations. Environmental Research Laboratories, Air Resources Atmosphere Turbulence and Diffusion Laboratory, NOAA, annual report, report ATDL-106.
Turner, D.B., 1964: A diffusion model for an urban area, J. Appl. Meteorol, 3,1, 83.
Sehmel, G.A, 1980: Particle and gas dry deposition: a review. Atm Env Vol 14, pp 983-1011.
Belot, Y., M. Roy, H. Métivier and al, 1996: Le tritium, de l’environnement à l’homme, IPSN, Les éditions de physique, ISBN: 286883-275-X.
Comte, N., L. Bourgois, J.P. Bourion – Organisation et schéma de calcul de conséquences radiologiques en situation accidentelle au CEA de saclay: logiciel SENTINEL. Technical Document.
Bateman, H, 1910: Cambridge Philosophical Society, volume 16, Page 423.
Achim, P. 2010: An operational meteorological forecast system at mesoscale for radiological and chemical assessment. HARMO’13, 1-4 June, Paris (France).
Guétat, Ph., P. Armand and M. Monfort, 2004: Calcul d’impact radiologique par voie atmosphérique en situation normale. Technical Document.
GuÉTat, Ph, 2004: Calcul d’impact radiologique d’un rejet liquide en situation normale. Formulaire du logiciel ABRICOT-CEA. Technical Document.
Arrêté du 20 novembre 2009 portant homologation de la décision n2009-DC-0153 de l’Autorité de Sûreté Nucléaire du 18 août 2009 relative aux niveaux d’intervention en situation d’urgence radiologique. Journal Officiel de la République française du 18 décembre 2009.
Eckerman, K.F. and J.C. Ryman, 1983: External exposure to radionuclides in air, water and soil. Federal Guidance Report 12-EPA 402-R-93-081.
Arrêté du 1er septembre 2003 définissant les modalités de calcul des doses efficaces et des doses équivalentes résultant de l’exposition des personnes aux rayonnements ionisants. Journal Officiel de la république Française.
ICRP, 1995: Age-dependant doses to members of the public from intake of radionuclides.
ICRP66, 1994: Human respiratory tract model for radiological protection.
Monfort, M., 2004: Comparaison des résultats du code MITHRA de dispersion atmosphérique avec ceux fournis par le code SIROCCO implanté dans l’application SENTINEL. Technical Document.
Legrand, J. and D. Manesse, 1982: Modèle IPSN pour le calcul simplifié de la dispersion atmosphérique des rejets accidentels. Rapport Cea-R-5170.