Hostname: page-component-848d4c4894-jbqgn Total loading time: 0 Render date: 2024-06-26T20:55:37.974Z Has data issue: false hasContentIssue false

Développements apportés au logiciel OEDIPE de simulation de mesures anthroporadiamétriques pour la prise en compte des données biocinétiques dans la modélisation de la contamination interne

Published online by Cambridge University Press:  12 June 2008

S. Lamart
Affiliation:
IRSN, Laboratoire d’Évaluation de la Dose Interne, DRPH/SDI/LEDI, B.P. 17, 92262 Fontenay-aux-Roses Cedex, France.
L. De Carlan
Affiliation:
IRSN, Laboratoire d’Évaluation de la Dose Interne, DRPH/SDI/LEDI, B.P. 17, 92262 Fontenay-aux-Roses Cedex, France.
E. Blanchardon
Affiliation:
IRSN, Laboratoire d’Évaluation de la Dose Interne, DRPH/SDI/LEDI, B.P. 17, 92262 Fontenay-aux-Roses Cedex, France.
D. Franck
Affiliation:
IRSN, Laboratoire d’Évaluation de la Dose Interne, DRPH/SDI/LEDI, B.P. 17, 92262 Fontenay-aux-Roses Cedex, France.
Get access

Abstract

Dans le cadre de l’amélioration des techniques d’étalonnage en anthroporadiamétrie, le Laboratoire d’Évaluation de la Dose Interne de l’IRSN a développé un outil numérique, « OEDIPE », pour modéliser la contamination interne dans des fantômes numériques voxélisés, simuler la mesure anthroporadiamétrique et estimer la dose interne. Si la précédente version d’OEDIPE permettait de bien modéliser des géométries de source comprenant un seul radionucléide localisé dans un organe particulier, elle était cependant limitée pour la modélisation d’une contamination formée d’un mélange de radionucléides dont la localisation évolue à partir de l’incorporation pour se distribuer dans plusieurs organes. Cet article a pour but de décrire les nouveaux modules développés pour permettre la définition de sources hétérogènes en composition et en répartition ainsi que l’importation automatique de distributions d’activité dérivées du calcul biocinétique. Ces nouveaux outils vont permettre d’étudier des cas de contamination plus complexes et l’influence de la biocinétique en mesure in vivo, afin de mieux estimer les coefficients d’étalonnage et les incertitudes correspondantes.

Type
Research Article
Copyright
© EDP Sciences, 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Aubineau-Lanièce, I., de Carlan, L., Clairand, I., Lemosquet, A., Chiavassa, S., Pierrat, N., Bardies, M., Franck, D. (2005a) Current developments at IRSN on computational tools dedicated to assessing doses for both internal and external exposure, Radiat. Prot. Dosim. 115, 522-529. CrossRef
Aubineau-Lanièce I., de Carlan L., Pierrat N., Franck D., Chiavassa S., Bardies M. (2005b) Application of voxel phantoms for internal dosimetry at IRSN using a dedicated computational tool. In: Monte Carlo 2005 Topical Meeting, Chattanooga, TN.
Borisov, N., Franck, D., de Carlan, L., Laval, L. (2002) A new graphical user interface for fast construction of computation phantoms and MCNP calculations: application to calibration of in vivo measurement systems, Health Phys. 83, 272-279. CrossRef
Borisov N., Franck D., De Carlan L., Pierrat N., Kochetkov O., Yatsenko V. (2005a) A new facility for MCNP application in whole body counting and internal dosimetry. In: Monte Carlo 2005 Topical Meeting, Chattanooga, TN.
Borisov N., Yatsenko V., Kochetkov O., Gusev I., Vlasov P., Kalistratova V., Nisimov P., Levochkin F., Borovkov M., Stolyarov V., Tsedish S., Tyurin I., Franck D., de Carlan L. (2005b) Checking a Monte Carlo utility for whole body counting during in vivo experiment. In: Monte Carlo 2005 Topical Meeting, Chattanooga, TN.
de Carlan L., Aubineau-Lanièce I., Diaz J.C., Jourdain J.R.J., Le Guen B., Pierrat N., Franck D. (2004) Potential of new imaging and calculation techniques for the activity and dose assessment in case of localized contamination. In: IRPA 2004, Madrid.
de Carlan, L., Roch, P., Blanchardon, E., Franck, D. (2005) New method of voxel phantom creation: application for whole-body counting calibration and perspectives in individual internal dose assessment, Radiat. Prot. Dosim. 116, 160-164. CrossRef
de Carlan L., Roch P., Blanchardon E., Franck D. (2007) Application of Voxel Phantoms in Whole-Body Counting for the Validation of Calibration Phantoms and the Assessment of Uncertainties, Radiat. Prot. Dosim. DOI: 10.1093/rpd/ncl117. CrossRef
Eckerman K.F., Leggett R.W., Cristy M., Nelson C.B., Ryman J.C., Sjoreen A.L., Ward R.C. (2001) DCAL: User’s Guide to the DCAL System, Report ORNL/TM-2001/190, Oak Ridge National Laboratory, USA.
Franck, D., Laval, L., Borissov, N., Guillierme, P., Bordy, J.M. (2001) Development of voxelised phantoms using MCNP Monte Carlo code: Application to in vivo measurement, Radioprotection 36, 77-86. CrossRef
Franck, D., Borissov, N., de Carlan, L., Pierrat, N., Genicot, J.L., Etherington, G. (2003) Application of Monte Carlo calculations to calibration of anthropomorphic phantoms used for activity assessment of actinides in lungs, Radiat. Prot. Dosim. 105, 403-408. CrossRef
Lamart S., de Carlan L., Blanchardon E., Franck D. (2007) Automatic application of ICRP biokinetic models in voxel phantoms for in vivo counting and internal dose assessment, Radiat. Prot. Dosim. DOI: 10.1093/rpd/ncm345. CrossRef
Pierrat, N., de Carlan, L., Cavadore, D., Franck, D. (2005) Application of monte carlo calculation for the virtual calibration of a low-energy in vivo counting system, IEEE Trans. Nucl. Sci. 52, 1353-1358. CrossRef