Balanced Window Method in 14C Liquid Scintillation Counting

Published online by Cambridge University Press:  18 July 2016

P Theodórsson*
Affiliation:
Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavík, Iceland.
S Ingvarsdottir
Affiliation:
Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavík, Iceland.
G I Gudjonsson
Affiliation:
Science Institute, University of Iceland, Dunhaga 3, IS-107 Reykjavík, Iceland.
*
Corresponding author. Email: pth@raunvis.hi.is.
Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The authors present a detailed theoretical and experimental study of the liquid scintillation balanced counting method, widely used in radiocarbon dating, using a simple, laboratory-made system. A fixed counting window becomes a balanced window when the high voltage is set where the 14C count rate rises to a maximum. Using a measured 14C pulse height spectrum, we have calculated the lower and upper limits for 11 balanced windows of varying width and their respective counting efficiencies. Furthermore, we have studied: (1) theoretically and experimentally, the counting efficiency for up to a ±15% shift in pulse height from the balanced setting, (2) the change in pulse height due to temperature variations, (3) the long-time stability of the system, and (4) a method that allows a quick determination of the balance voltage for individual samples, using the Compton spectrum of 133Ba. The standard deviation for thirty 24-hr measuring periods for a 14C standard (190 Bq) was within the expected statistical standard error (0.03%).

Type
Notes & Comments
Copyright
Copyright © The Arizona Board of Regents on behalf of the University of Arizona 

References

Arslanov, K. 1991. Radiocarbon: geochemistry and geochronology. Leningrad: Leningrad University Press. In Russian.Google Scholar
Gudjonsson, GI, Theodórsson, P. 2000. A compact automatic low-level liquid scintillation system for radon-in water by pulse pair counting. Applied Radiation and Isotopes 53:377–80.CrossRefGoogle ScholarPubMed
Horrocks, DL. 1979. Energy per photoelectron in a coincidence liquid scintillation counter as a function of electron energy. In: Peng, C-T, Horrocks, DL, Alpen, EL, editors. Liquid scintillation counting: recent applications and development. New York: Academic Press. p 1629.Google Scholar
McCormac, FG. 1992. Liquid scintillation counter characterization, optimization, and benzene purity correction. Radiocarbon 34(1):3745.Google Scholar
Pearson, GW. 1979. Precise 14C measurement by liquid scintillation counting. Radiocarbon 21(1):121.Google Scholar
Pearson, GW. 1983. The development of 14C measurement and its application to archaeological timescale problems. PhD dissertation. Belfast: The Queen's University of Belfast.Google Scholar
Theodórsson, P. 2000. A multi-sample liquid scintillation counting system for weak beta emitting samples with single phototube detectors. Applied Radiation and Isotopes 53:297301.CrossRefGoogle ScholarPubMed