About 1876 the author had occasion to devise a method of indicating the rate of flow of a liquid through a pipe system, without interfering with the flow. For this purpose he used a ball, heavier than the liquid, in a slightly tapered glass tube, through which the liquid flowed from the narrower to the wider end. In the first instance the tube was set vertical, with the wider part above. The ball fitted more or less closely at the lower end: it was carried up by the current till the clearance round it became such as to suit the particular rate of flow. Its height was read off on a scale fixed alongside of the tube, and served to indicate the rate of the flow, once the relation of scale-reading to flow had been experimentally determined.

Type
Proceedings
Copyright
Copyright © Royal Society of Edinburgh 1926

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

page 314 note * The author is indebted for the measurement of the viscosity to Dr Ezer Griffiths of the National Physical Laboratory, who, along with his assistant, Mr J. H. Awbery, has taken part in developing and testing the device. Their experiments confirm the author's, which were carried out in Edinburgh.