Abstract

A neurointerventional training model called HANNES (Hamburg ANatomical NEurointerventional Simulator) has been developed to replace animal models in catheter-based aneurysm treatment training. A methodical approach to design for mass adaptation is applied so that patient-specific aneurysm models can be designed recurrently based on real patient data to be integrated into the training system.

HANNES’ modular product structure designed for mass adaptation consists of predefined and individualized modules that can be combined for various training scenarios. Additively manufactured, individualized aneurysm models enable high reproducibility of real patient anatomies. Due to the implementation of a standardized individualization process, order-related adaptation can be realized for each new patient anatomy with modest effort. The paper proves how the application of design for mass adaptation leads to a well-designed modular product structure of the neurointerventional training model HANNES, which supports quality treatment and provides an animal-free and patient-specific training environment.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Design for Mass Adaptation of the Neurointerventional Training Model HANNES with Patient-Specific Aneurysm Models
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Design for Mass Adaptation of the Neurointerventional Training Model HANNES with Patient-Specific Aneurysm Models
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Design for Mass Adaptation of the Neurointerventional Training Model HANNES with Patient-Specific Aneurysm Models
      Available formats
      ×

Copyright

This is an Open Access article, distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives licence (http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is unaltered and is properly cited. The written permission of Cambridge University Press must be obtained for commercial re-use or in order to create a derivative work.

Corresponding author

Contact: Kuhl, Juliane, Hamburg University of Technology, Institute of Product, Development and Mechanical Engineering Design, Germany, juliane.kuhl@tuhh.de

References

Hide All
Berlis, A. (2017), “Endovaskuläre Behandlung von Hirn-Aneurysmen Hirn- Aneurysma/ Angiom”, in: Berlis, A. and Schneebauer, C. (Eds.), Kompendium für Betroffene, Angehörige und Interessierte, Association for brain aneurysm sufferers, Der Lebenszweig e.V. (own publishing house), http://www.hirn-aneurysma.de/files/redakteur/Kompendium%20Testseiten.pdf, accessed date 29.11.2018
Blees, C., Jonas, H. and Krause, D. (2010), “Development of modular product families”, 12th International DSM Conference, Cambridge, 22-23 July 2010, Carl-Hanser-Verlag, Munich, pp. 169182
Bouzeghrane, F., Naggara, O., Kallmes, D.F., Berenstein and, A. and Raymond, J. (2010), “In vivo experimental intracranial aneurysm models: a systematic review”, American Journal of Neuroradiology, March 2010, Vol. 31 No. 3, pp. 418423, https://doi.org/10.3174/ajnr.A1853
FAIN-Biomedical (2018), Endovascular Surgery Training-Evaluation-Simulation EVE EndoVascular Evaluator, http://fain-biomedical.com/fbm_wp/wp-content/themes/fbm_ns/images/pdf/eve_fbm_e.pdf, accessed date 29.11.2018
Fiehler, J. (2012), “Nicht rupturierte intrakranielle aneurysmen: wann suchen, wann behandeln?RöFo : Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin, Vol. 184 No. 2, Georg Thieme Verlag KG, Stuttgart, pp. 97104, https://doi.org/10.1055/s-0031-1281984
Frölich, A.M.J., Spallek, J., Brehmer, L., Buhk, J.-H., Krause, D., Fiehler, J. and Kemmling, A. (2015), “3D printing of intracranial aneurysms using fused deposition modeling offers highly accurate replications”, AJNR American Journal of Neuroradiology, originally published online on August 20, 2015, https://doi.org/10.3174/ajnr.A4486
Hacke, W. and Poeck, K. (2010), Neurologie: Mit 83 Tabelle, 13th completely revised edition, Springer-Medizin-Verlag, Heidelberg, https://doi.org/10.1007/978-3-662-46892-0
Ionita, C.N., Mokin, M., Varble, N., Bednarek, D.R., Xiang, J., Snyder, K.V., Siddiqui, A.H., Levy, E.I., Meng, H. and Rudin, S. (2014), “Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing”, SPIE--the International Society for Optical Engineering, Vol. 9038 p. 90380M., https://doi.org/10.1117/12.2042266
Kipp, T. (2012), “Methodische unterstützung der variantengerechten produktgestaltung”.Dissertation TU Hamburg-Harburg, TuTech Verlag Hamburg, Hamburger Schriftenreihe Produktentwicklung und Konstruktionstechnik, Band 4, ISBN 978-3-941492-47-9
Krause, D. and Gebhardt, N. (2018), Methodische Entwicklung modularer Produktfamilien - Hohe Produktvielfalt beherrschbar entwickeln, Springer-Verlag, Hamburg, 2018, https://doi.org/10.1007/978-3-662-53040-5
Krause, D., Spallek, J., Blees, C. and Kipp, T. (2018), “Modulare Produktstrukturierung”, In: Rieg, F. and Steinhilper, R. (Ed.), Handbuch Konstruktion, Carl Hanser Verlag, München, pp. 719741, https://doi.org/10.3139/9783446434035
Nawka, M. T., Fiehler, J., Spallek, J., Buhk, J.-H. and Frölich, A.M. (2018), “Current status of training environments in neuro-interventional practice: are animal models still contemporary?”, Journal of Neurointerventional Surgery, 2018 Jul 26, https://doi.org/10.1136/neurintsurg-2018-014036
Neequaye, S. K., Aggarwal, R.,Van Herzeele, I., Darzi, A. and Cheshire, N.J. (2017), “Endovascular skills training and assessment”, Journal of vascular surgery, Vol. 46, pp. 10551064, https://doi.org/10.1016/j.jvs.2007.05.041
Rudberg, M. and Wikner, J. (2004), “Mass customization in terms of the customer order decoupling point”, Production Planning & Control Vol. 15 No. 4, S. 445458. https://doi.org/10.1080/0953728042000238764.
Russ, M., O'Hara, R., Setlur Nagesh, S. V., Mokin, M., Jimenez, C., Siddiqui, A., Bednarek, D., Rudin, S. and Ionita, C. (2015), “Treatment planning for image-guided neuro-vascular interventions using patient-specific 3d printed phantoms”, Proceedings of SPIE--the International Society for Optical Engineering 9417
Russell, W.M.S. and Burch, R.L. (1959), The Principles of Humane Experimental Technique, Methuen, London
Schmidt, P. (2018), “Konzeptentwicklung einer röntgenfreien trainingsumgebung für aneurysmabehandlungen”, Master Thesis at the Institute of Product Development and Mechanical Engineering Design, Hamburg University of Technology
Simgen, A., Junk, D. and Reith, W. (2012), “Flow diverter. eine neue therapiemöglichkeit für intrakranielle aneurysmen”, Der Radiologe, Vol. 52 No. 12, pp. 11181124
Simbionix USA Corporation (2017), ANGIO Mentor. The Most Advanced Endovascular Training, URL: http://simbionix.com/simulators/angio-mentor/, accessed date 29.11.2018
Spallek, J., Frölich, A., Buhk, J.H., Fiehler, J. and Krause, D. (2016a), “Comparing technologies of additive manufacturing for the development of vascular models”, Fraunhofer Direct Digital Manufacturing Conference DDMC, Fraunhofer Verlag, Berlin.
Spallek, J. and Krause, D. (2016b), “Process types of customisation and personalisation in design for additive manufacturing applied to vascular models”, 26th CIRP Design Conference, Vol. 50, Procedia CIRP, Elsevier, pp. 281286, http://doi.org/10.1016/j.procir.2016.05.022
Spallek, J., Sankowski, O. and Krause, D. (2016c), “Influences of additive manufacturing on design processes for customised products”, 14th International Design Conference - DESIGN 2016, Cavtat, Dubrovnik, Croatia, pp. 513522, https://doi.org/10.13140/RG.2.1.1112.4080
Vascular Simulations (2018), Optimize Your Performance, https://vascularsimulations.com/technology/, accessed date 29.11.2018

Keywords

Design for Mass Adaptation of the Neurointerventional Training Model HANNES with Patient-Specific Aneurysm Models

  • Johanna Spallek (a1), Juliane Kuhl (a1), Nadine Wortmann (a1), Jan-Hendrik Buhk (a2), Andreas Maximilian Frölich (a2), Marie Teresa Nawka (a2), Anna Kyselyova (a2), Jens Fiehler (a2) and Dieter Krause (a1)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed