Hostname: page-component-8448b6f56d-m8qmq Total loading time: 0 Render date: 2024-04-24T14:56:28.024Z Has data issue: false hasContentIssue false

Nanostructured (Sn,Ti, Nb)O2 Solid Solution for Hydrogen Sensing

Published online by Cambridge University Press:  01 February 2011

Maria Cristina Carotta
Affiliation:
carotta@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, N/A, 44100, Italy, 00390532974230, 00390532974210
Michele Benetti
Affiliation:
benetti@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Vincenzo Guidi
Affiliation:
guidi@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Sandro Gherardi
Affiliation:
gherardi@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Cesare Malagu'
Affiliation:
malagu@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Beatrice Vendemiati
Affiliation:
vendemiati@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Giuliano Martinelli
Affiliation:
martinelli@fe.infn.it, University of Ferrara, Physics Department, Via Saragat 1/C, Ferrara, n/a, 44100, Italy
Get access

Abstract

A novel co-precipitation route for preparing pure nanograined (Ti, Sn, Nb)O2 solid solution has been accomplished. The solid solution containing the three elements has been synthesized with the molar ratios for Sn:Ti:Nb 100:42:5. Electron microscopy and X-ray diffraction have been adopted to observe the morphology, the crystalline structure and the mean grain radius. Calcining at 550, 650, 850 or 1050 °C for 2h, showed rutile-like single-phase.

The prepared powders have been deposited to produce gas sensors in form of thick films through screen-printing technology. SEM micrographs of both powders and films showed regularly-shaped particles with grain dimensions at nanometric level, the nanostructure being maintained up to 1050°C. The sensors have been tested with different reducing gases showing large responses to hydrogen and good selectivity.

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Radwcka, M., Zakrzewska, K., Rekas, M., Sensors and Actuators B, 47, 194 (1998).Google Scholar
[2] Malagù, C., Guidi, V., Carotta, M.C., Martinelli, G., Appl. Phys. Lett. 84, 4158 (2004).Google Scholar
[3] Chung, W.Y., Lee, D.D., Sohn, B.K, Thin Solid Films 221, 304 (1992).Google Scholar
[4] Williams, D.E., Sensors and Actuators B, 57, 1 (1999)Google Scholar
[5] Carney, C. M., Yoo, S., Akbar, S. A., Sensors and Actuators B, 108, 29 (2005).Google Scholar
[6] Benetti, M., Blo, M., Carotta, M.C., Guidi, V., Keppel, G., Martinelli, G., Sacerdoti, M., Vendemiati, B., Zanni, A., Proc. of Eurosensors XIX, 11-14 September 2005, Barcelona, Spain.Google Scholar
[7] Lantto, V., Romppainen, P. and Leppävuori, S., Sensors and Actuators, 14, 149 (1988).Google Scholar
[8] Lin, J., Yu, J. C., Lo, D. and Lam, S. K., Journal of Catalysis, 183, 368 (1999).Google Scholar