Hostname: page-component-8448b6f56d-cfpbc Total loading time: 0 Render date: 2024-04-24T14:50:57.808Z Has data issue: false hasContentIssue false

Measurement of Residual Strains with High Depth Resolution by Energy-Variable Diffraction on Synchrotron Beam Lines

Published online by Cambridge University Press:  01 February 2011

E. Zolotoyabko
Affiliation:
Department of Materials Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel.
B. Pokroy
Affiliation:
Department of Materials Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel.
J. P. Quintana
Affiliation:
Northwestern University, DND-CAT, APS/ANL Sector 5, Building 432A, 9700 South Cass Avenue, Argonne, IL 60439–4857, U.S.A.
Get access

Abstract

An energy-variable synchrotron diffraction technique is established as a novel method for depth-resolved measurements of d-spacings and residual strains in polycrystalline structures. The depth sensitivity is achieved by the controlled changing the x-ray energy and, hence, the x-ray penetration into the sample. Quasi-parallel synchrotron radiation being diffracted at different depths deviates differently from the detector axis. As a result, the maximum diffraction intensity recorded in the detector is coming from a certain depth, which is energy dependent. This finding opens a way for strain measurements with high depth resolution by changing the x-ray energy in small enough steps. The developed technique is applied to characterize the electrodeposited Cu/Ni multilayers.

Type
Research Article
Copyright
Copyright © Materials Research Society 2005

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Poulsen, H. F., Jensen, D. J., and Vaughan, G. B. M., MRS Bulletin 29, 166 (2004).Google Scholar
[2] Zolotoyabko, E. and Quintana, J. P., Rev. Sci. Instr. 73, 1663 (2002).Google Scholar
[3] Zolotoyabko, E. and Quintana, J. P., Nucl. Instr. & Meth. B200, 382 (2003).Google Scholar
[4] Zolotoyabko, E. and Quintana, J. P., J. Appl. Cryst. 35, 594 (2002).Google Scholar
[5] Pokroy, B. and Zolotoyabko, E., J. Materials Chemistry 13, 682 (2003).Google Scholar
[6] Zolotoyabko, E., Pokroy, B., and Quintana, J. P., J. Synchrotr. Rad. 11, 309 (2004).Google Scholar
[7] van Heerden, D., Zolotoyabko, E., and Shechtman, D., (1996). J. Mater. Research 11, 2825 (1996).Google Scholar
[8] Lashmore, D. S. and Dariel, M. P., J. Electroch. Soc. 135, 1218 (1990).Google Scholar