Hostname: page-component-84b7d79bbc-dwq4g Total loading time: 0 Render date: 2024-08-01T01:05:46.116Z Has data issue: false hasContentIssue false

The Influence of Facility Conditions on A ±0.25 °C Repeatability Lamp Voltage Controlled RTP System

Published online by Cambridge University Press:  10 February 2011

Peter Vandenabeele
Affiliation:
SensArray Corporation, Bouwelsesteenweg 203A, 2560 Nijlen, BELGIUM, P.Vandenabeele@ping.be
Wayne Renken
Affiliation:
SensArray Corporation, 3410 Garrett Drive, Santa Clara, CA 95054, Wayne_Renken@sensarray.com
Get access

Abstract

The influence of cooling air and cooling water parameters on the wafer temperature was studied in an RTP system with lamp power control. With a cool down time of 150 seconds between consecutive heating cycles, the wafer temperature in a 1050 °C process was highly sensitive to cooling air flow. With a cool down time of 330 seconds the sensitivity dropped a factor of 5. This was explained through the effect of radiative heat transfer from the quartz to the wafer at higher quartz temperatures (>200 °C). Other factors are variations in the water flow through the oven walls and the repeatability of wafer positioning.

Type
Research Article
Copyright
Copyright © Materials Research Society 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Vandenabeele, Peter and Renken, Wayne, MRS San Francisco, April 1997, this volume.Google Scholar
[2] Nakos, James, RTP'93, Fair, R. B., Lojek, B., Editors, 421 (1993).Google Scholar