Article contents
The Influence of Facility Conditions on A ±0.25 °C Repeatability Lamp Voltage Controlled RTP System
Published online by Cambridge University Press: 10 February 2011
Abstract
The influence of cooling air and cooling water parameters on the wafer temperature was studied in an RTP system with lamp power control. With a cool down time of 150 seconds between consecutive heating cycles, the wafer temperature in a 1050 °C process was highly sensitive to cooling air flow. With a cool down time of 330 seconds the sensitivity dropped a factor of 5. This was explained through the effect of radiative heat transfer from the quartz to the wafer at higher quartz temperatures (>200 °C). Other factors are variations in the water flow through the oven walls and the repeatability of wafer positioning.
- Type
- Research Article
- Information
- Copyright
- Copyright © Materials Research Society 1997
References