Improvement of the Corrosion Resistance of NiTi Stents by Surface Treatments

  • C. Trépanier (a1), M. Tabrizian (a1), LH. Yahia (a1), L. Bilodeau (a2) and D. L. Piron (a3)...

Abstract

Because of its optimal radiopacity, superelasticity and shape memory properties Nickel-Titanium (NiTi) is an ideal material for the fabrication of stents. Indeed, these properties can facilitate the implantation and precise positioning of those devices. However, in vitro studies on NiTi report the dependency of the alloy biocompatibility and corrosion behavior to surface treatments. Oxidation of the surface seems to be very promising to improve both the corrosion resistance and the biocompatibility of NiTi. The present study investigate the effect of electropolishing, heat treatment (in air and in a salt bath) and nitric acid passivation to modify the oxide layer on NiTi stents. Techniques such as potentiodynamic polarization tests, Scanning Electron Microscopy (SEM) and Auger Electron Spectroscopy (AES) have been used to develop relationships between corrosion behavior, surface characteristics and surface treatment. Results show that all surface treatments improve the corrosion behavior of the alloy. SEM results indicate that treated stents which exhibit a smooth and uniform surface show a higher corrosion resistance than non treated stents which possess a very porous oxide layer. AES results, indicate that the best corrosion behavior was observed for the stents which exhibit the thinnest oxide layer (electropolished and passivated samples).

Copyright

References

Hide All
1. Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., Kappenberger, L., N. Eng. J. Med., 316, 12, p. 701, (1987).
2. Serruys, P.W. et al., N. Eng. J. Med., 331, p. 489, (1994).
3. Lau, K.W., Sigwart, U., Ind. Heart J., 43, 3, p. 127, (1991).
4. Putters, J.L.M., Kaulesar Sukul, D.M.K.S., de Zeeuw, G.R., Bijma, A., Besselink, P.A., Eur. Surg. Res., 24, p. 378, (1992).
5. Assad, M., Yahia, L'H., Desrosiers, E.A., Lombardi, S., Rivard, C.H. in Shape Memory and Superelastic Technologies, edited by Pelton, A., Hodgson, D. and Duerig, T. (Shap. Mem. Super. Tech. Proc, Pacific Grove, CA, 1994), p. 215.
6. Shabalovskaya, S., Cunnick, J., Anderegg, J., Harmon, K., Sachdeva, R. in Shape Memory and Superelastic Technologies, edited by Pelton, A., Hodgson, D. and Duerig, T. (Shap. Mem. Super. Tech. Proc, Pacific Grove, CA, 1994), p. 209.
7. Berger-Gorbet, M., Broxup, B., Rivard, C.H., Yahia, L'H., J. Biomed. Mat. Res., 32, p. 243, (1996).
8. Villermaux, F., Tabrizian, M., Yahia, L'H., Meunier, M., Piron, D.L., Appl. Surf. Sci., (in press).
9. Sohmura, T., (World Biomat. Congress Proc, Kyoto, Japan, 1988), p. 574.
10. Espinos, J.P., Fernandez, A., Gonzalez-Elipe, A.R., Surf. Sci., 295, p. 402, (1993).
11. ASM Handbook, 5, ASM International, p. 835, (1994).
12. Wisbey, A., Peter, P.J., Tuke, M., Biomat., 12, p. 470, (1990).
13. Annual Boof ASTM Standards, 13.01, ASTM, Philadelphia, (1996).
14. Chan, C., Trigwell, S., Duerig, T., Surf. Interf. Anal., 15, p. 349, (1990).

Improvement of the Corrosion Resistance of NiTi Stents by Surface Treatments

  • C. Trépanier (a1), M. Tabrizian (a1), LH. Yahia (a1), L. Bilodeau (a2) and D. L. Piron (a3)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed