Hostname: page-component-848d4c4894-nmvwc Total loading time: 0 Render date: 2024-06-24T14:28:06.216Z Has data issue: false hasContentIssue false

Hydrogel Based Composite Materials for Chemical, Biological and Medical Sensing Applications

Published online by Cambridge University Press:  01 February 2011

Timothy L. Porter
Affiliation:
tim.porter@nau.edu, Northern Arizona University, Physics, Bldg. 19, Room 209, Flagstaff, AZ, 86011, United States
Tim Vail
Affiliation:
tim.vail@nau.edu, Northern Arizona University, Flagstaff, AZ, 86011, United States
Jim Reed
Affiliation:
jreed@baymaterials.com, Cantimer, Inc., Menlo Park, CA, 94025, United States
Ray Stewart
Affiliation:
rays@baymaterials.com, Cantimer, Inc., Menlo Park, CA, 94025, United States
Get access

Abstract

Embedded piezoresistive microcantilever (EPM) sensors provide a tiny, low-cost, and robust platform for the detection of chemical or biological analytes. New sensing applications become potentially available as the design or synthesis of new sensing materials for EPM instruments are studies. In this study, we report on the detection of hydrogen fluoride gas (HF) in air, and in a medical application, the measurement of human hydration levels. Two sensing materials characterize these applications, thiolated gold nanoparticles in a keratin matrix (HF), and a crosslinked PVA-based hydrogel in the hydration application.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Porter, T.L. et al. , An Embedded Polymer Piezoresistive Microcantilever Sensor. Ultramicroscopy, 2003. 97: p. 365369.Google Scholar
2. Porter, T.L., et al., Sensor Based on Piezoresistive Microcantilever Technology. Sensors and Actuators, 2001. A88: p. 4751.Google Scholar
3. Kooser, A., et al., Investigation of the Antigen Antibody Reaction Between Anti-Bovine Serum Albumin and Bovine Serum Albumin Using Piezorsistive Microcantilever Sensors. Biosensors and Bioelectronics, 2003. 19: p. 503508.Google Scholar
4. Gunter, R.L., et al., Viral Detection Using an Embedded Piezoresistive Microcantilever Sensor. Sensors and Actuators (A), 2003. A107: p. 219224.Google Scholar
5. Porter, T.L., et al., Viral Detection Using an Embedded Piezoresistive Microcantilever Sensor. Sensors and Actuators (A), 2003. 107(3): p. 219224.Google Scholar
6. Kooser, A., et al., Gas Sensing Using Embedded Piezoresistive Microcantilever Sensors. Sensors and Actuators, 2004. 99(2-3): p. 430433.Google Scholar
7. Porter, T.L., Delinger, W., and Gunter, R.L., Embedded Piezoresistive Microcantilever Sensors: Materials for Sensing Chemical and Biological Analytes. Proc. Materials Research Soc., 2005.Google Scholar