Hostname: page-component-84b7d79bbc-rnpqb Total loading time: 0 Render date: 2024-07-28T02:03:35.234Z Has data issue: false hasContentIssue false

Design of a Novel Electrically Conducting Biocompatible Polymer with Degradable Linkages for Biomedical Applications

Published online by Cambridge University Press:  01 February 2011

Nathalie Kathryn Guimard
Affiliation:
nguimard@mail.utexas.edu, University of Texas at Austin, Department of Chemistry and Biochemistry, 1 University Station, A5300, Austin, TX, 78712, United States
Jonathan L. Sessler
Affiliation:
sessler@mail.utexas.edu, University of Texas at Austin, Department of Chemistry and Biochemistry, 1 University Station, A5300, Austin, TX, 78712, United States
Christine E. Schmidt
Affiliation:
schmidt@che.utexas.edu, University of Texas at Austin, Department of Biomedical Engineering, 1 University Station, MC C0400, Austin, TX, 78712, United States
Get access

Abstract

Upon the discovery of the first conducting polymer in 1976, the replacement of metal-based semiconductors in many applications with conducting polymers was inevitable. Perhaps more surprisingly these materials showed promise in many biomedical applications. The finding that electrical fields and charges modulate shape, size, and proliferation of a number of cell types including nerve and bone, has prompted biomedical engineers to focus on the development of conducting polymer scaffolds for tissue regeneration and neural probes. A number of polymers have been studied for these applications, including polypyrrole (PPy), polythiophene, and polyaniline. One serious limitation to the use of conducting polymers in biological systems is their inability to degrade. Therefore, it has been proposed to design and synthesize a biocompatible, biodegradable, semiconducting polymer, which could broaden the scope of applications for conducting polymers. For instance, these unique polymers could potentially be implemented in temporary tissue and neural scaffolds, drug delivery, short-term electrodes, and tethers between nanotubes. Therefore, the goal of this investigation is to synthesize a polymer that is degradable, while maintaining conductivity. Initially, the incorporation of pyrrole oligomers into a biodegradable polymer was attempted; however, to overcome difficulties associated with the instability of these oligopyrroles, a novel polymer design has been proposed which incorporates thiophene oligomers. Oligothiophenes (OTs) are apt to be more conductive than oligopyrroles due to a smaller band gap between the valence and conductance bands. Additionally, OTs share many of the advantageous properties of oligopyrroles, including cell compatibility, but are more stable. The proposed novel co-polymer consists of quaterthiophene oligomers tethered together by aliphatic ester linkages, which would potentially render the co-polymer conductive by means of inter and intra chain oligo overlap and degradable via cleavage of the ester bond by esterases in the body. The synthesis of the novel copolymer, poly-dialcohol dimethyl quaterthiophene-co-adipic acid (PAMQAA) has been completed successfully and corroborated by NMR and MALDI. Initial characterization indicates PAMQAA has the following properties: Mw = 11,240-64,080 g/mol, PI = 1.2-1.4, degradation temperature = ∼160°C. Currently PAMQAA is being characterized to assess its Tg, Tm, conductivity, degradability, and biocompatability. Polymer modifications could allow further optimization of properties, such as the rate of degradation and conductivity, to target better the application of interest.

Type
Research Article
Copyright
Copyright © Materials Research Society 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Jaffe, L F, Poo, M M, Neurites grow faster towards the cathode than the anode in a steady field. J Exp Zool 1979;209:115128.Google Scholar
2. Giaever, I, Keese, C R. Monitoring fibroblast behavior in tissue culture with an applied electric field. Proc Natl Acad Sci USA 1984;81:37613764.Google Scholar
3. Kerns, J M, Pavkovic, I M, Fakhouri, A J, Wickersham, K L, Freeman, J A. An experimental implant for applying a DC electrical field to peripheral nerve. J Neurosci Meth 1987;19:217223.Google Scholar
4. Aebischer, P, Valentini, R F, Dario, P, Domenici, C, Galleti, P M. Piezoelectric guidance channels enhance regeneration in the mouse sciatic nerve after axotomy. Brain Res 1987;436:165168.Google Scholar
5. Fine, G, Valentini, R F, Bellamkonda, R, Aebischer, P. Improved nerve regeneration through piezoelectric vinylidenefluoride-trifluoroethylene copolymer guidance channels. Biomater 1991;12:775780.Google Scholar
6. Wong, J Y, Langer, R, Ingber, D E. Electrically conducting polymers can noninvasively control the shape and growth of mammalian cells. Proc Natl Acad Sci USA 1994;91:32013204.Google Scholar
7. Schmidt, C E, Shastri, V R, Vacanti, J P, Langer, R. Stimulation of neurite outgrowth using an electrically conducting polymer. Proc Natl Acad Sci USA 1997;94:89488953.Google Scholar
8. Zelikin, A N, Lynn, D M, Farhadi, J, Martin, I, Shastri, V, Langer, R. Erodible conducting polymers for potential biomedical applications. Angew Chem Int 2002;41:141145.Google Scholar
9. Shi, G, Rouabhia, M, Wang, Z, Dao, L H, Zhang, Z. A novel electrically conductive and biodegradable composite made of polypyrrole nanoparticles and polylactide. Biomaterials 2004;25:24772488.Google Scholar
10. Rivers, T J, Hudson, T W, Schmidt, C E. Synthesis of a novel, biodegradable electrically conducting polymer for biomedical applications. Adv Funct Mater 2002;12:3337.Google Scholar