Skip to main content Accessibility help
×
Home

Accelerated Reliability Test Inputs in Analyzing the Device Response of MgZnO Based UV Detector

  • S.S. Hullavarad (a1), I. Takeuchi (a1), J. Berger (a1), S. Dhar (a1), K.S. Chang (a1), T. Venkatesan (a1), T.C. Loughran (a2), R.D. Vispute (a3) and S.N. Yedave (a3)...

Abstract

In this paper we present the accelerated reliability testing of MgZnO based UV detectors. The UV detectors are fabricated on glass, quartz and sapphire substrates by Pulsed Laser Deposition (PLD) technique. The films are highly oriented and show sharp transmission at 350nm and 330nm for Mg composition of 10% and 20% in ZnO, respectively. The device response has been studied and life expectancy of the devices has been estimated from the accelerated tests.

Copyright

References

Hide All
[1] Brennan, K.F., Haralson, J., Parks, J.F., Salem, A., Microelectronics Reliability 39, 1873 (1999)10.1016/S0026-2714(99)00197-3
[2] Bagnall, D.M., Chen, Y.F., Zhu, Z., Yao, T., Koyama, S., Shen, H., and Goto, T., Appl. Phys. Lett. 70, 2230 (1997)10.1063/1.118824
[3] Ohtomo, A., Kawasaki, M., Sakurai, Y., Yoshida, Y., Koinuma, H., Yu, P., Tang, Z.K., Wong, G. K., and Segawa, Y., Mater. Sci. Eng., B 54, 24 (1998)10.1016/S0921-5107(98)00120-2
[4] Look, D.C., Mater. Sci. Eng., B 80, 383 (2001)10.1016/S0921-5107(00)00604-8
[5] Tang, Z. K., Yu, P., Wong, G. K. L., Kawasaki, M., Ohtomo, A., Koinuma, H., and Segawa, Y., Solid State Commun. 103, 459(1997)10.1016/S0038-1098(97)00254-8
[6] Narayan, J., Sharma, A.K., Kvit, A., Jin, C., Muth, J. F., and Holland, O. W., Solid State Commun. 121, 9 (2002)10.1016/S0038-1098(01)00431-8
[7] Choopun, S., Vispute, R. D., Yang, W., Sharma, R. P., Venkatesan, T., and Shen, H., Appl. Phys. Lett. 80, 1529 (2002)10.1063/1.1456266
[8] Auret, F. D., Goodman, S. A., Hayes, M., Legodi, M. J., van Laarhoven, H. A., and Look, D. C., Appl. Phys. Lett. 79, 3074 (2001)10.1063/1.1415050
[9] Vispute, R.D., Talyansky, V., Choopun, S., Sharma, R. P., and Venkatesan, T. He, M., Tang, X., Halpern, J.B., and Spencer, M. G., Li, Y. X. and Salamanca-Riba, L. G. Iliadis, A. A., Jones, K. A. Appl. Phys. Lett. 73, 348 (1998)10.1063/1.121830
[10] MgZnO based UV detectors on glass, quartz, polyamide substrates: A Comparative study S.S. Hullavarad, R.D. Vispute, I. Takeuchi, T. Venkatesan, To be published.
[11] Yoshida, S. and Suzuki, J., Appl. Phys. Lett 85, 7931 (1998)

Accelerated Reliability Test Inputs in Analyzing the Device Response of MgZnO Based UV Detector

  • S.S. Hullavarad (a1), I. Takeuchi (a1), J. Berger (a1), S. Dhar (a1), K.S. Chang (a1), T. Venkatesan (a1), T.C. Loughran (a2), R.D. Vispute (a3) and S.N. Yedave (a3)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed