Hostname: page-component-77c89778f8-5wvtr Total loading time: 0 Render date: 2024-07-19T05:27:41.525Z Has data issue: false hasContentIssue false

Dual Ion Implantations of Si+As and S+As into GaAs

Published online by Cambridge University Press:  21 February 2011

W. D. Fan
Affiliation:
Shanghai Institute of Metallurgy, Academia Sinica, Shanghai 200050, China
W. Y. Wang
Affiliation:
Shanghai Institute of Metallurgy, Academia Sinica, Shanghai 200050, China
B. L. Zhou
Affiliation:
Xsirius Superconductivity Inc., Scottsdale, Arizona 85260, USA
Get access

Abstract

As+ implantation has been used to compensate the As loss during annealing for Si- or S-implanted GaAs. The As+ implantation was at an energy range of 25–100KeV to a dose range of 1012-1015cm−2. The Si+ or S+ implantation was at 150 or 50KeV respectively to the same dose, 27times;1013cm−2. By using the measurements of the Hall effect and sheet resistivity, the activation efficiency and mobility of the dually implanted sample with Si+ and As+ (25KeV, 1×1013cm− 2 ) after TA at 1050°C for 6s increase by 21 and 18% respectively over those of the singly Si-implanted sample after TA at 1100°C for 6s. Those of the dually implanted sample with Si+ and As+ (100KeV, 1×1013cm− 2 ) increase by 63 and 30% respectively over those of the singly Si-implanted sample after FA at 800°C for 30min. Also, the density of SiAs and VGa determined by 20K PL spectra decreases of dually Si- and As-implanted samples. The activation efficiency and mobility of the d8ally implanted sample with S+ and As+ (40KeV, 1×1013cm−2 ) after TA at 1100°C for 12s increase by 17 and 16% respectively over those of the singly Simplanted sample. The annealing behaviour after As+ implantation is discussed.

Type
Research Article
Copyright
Copyright © Materials Research Society 1989

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Fan, W.D., Jiang, X.Y., Xia, G.Q. and Wang, W.Y., in Gallium Arsenide and Related Compounds 1986, edited by Lindley, W.T. (IOP Publishing Ltd, Bristol, 1987), pp.277282; A.R. Von Neida, S.J. Pearton, M. Stavola and R. Caruso, in Gallium Arsenide and Related Compounds 1986, edited by W.T. Lindley (IOP Publishing Ltd, Bristol, 1987), pp.57–62.Google Scholar
2. Tamura, A., Uenoyama, T., Nishii, K., Inoue, K. and Onuma, T., J. Appl. Phys. 62, 1102 (1987).Google Scholar
3. Reynolds, S., Vook, D.W., Opyd, W.G. and Gibbons, J.F., Appl. Phys. Lett. 51, 916 (1987).Google Scholar
4. Hyuga, F., Yamazaki, H., Watanabe, K. and Osaka, J., Appl. Phys. Lett. 50, 1592 (1987).Google Scholar
5. Itoh, T. and Takeuchi, M., Jpn. J. Appl. Phys. 16, 227 (1977).Google Scholar
6. Lun, W.Y. and Wieder, H.H., J. Appl. Phys. 49, 6187 (1978).Google Scholar
7. Stolte, C.A., in Ion Implantation in Semiconductors 1976, edited by Chernow, F., Borders, J.A. and Brice, D.K. (Plenum Publishing Corporation, New York, 1977), p. 149.Google Scholar
8. Bhattacharya, R.S., Rai, A.K., Yeo, Y.K., Pronko, P.P. and Park, Y. S., Nuclear Instruments and Methods, 209/210, 637 (1983).Google Scholar
9. Greiner, M.E. and Gibbons, J.F., J. Appl. Phys. 57, 5181 (1985).Google Scholar