Hostname: page-component-848d4c4894-xfwgj Total loading time: 0 Render date: 2024-06-30T06:34:53.426Z Has data issue: false hasContentIssue false

Radiopaque and biodegradable beads fabricated with Lipiodol and polycaprolactone for transarterial chemoembolization

Published online by Cambridge University Press:  15 February 2019

Yutaka Okamoto
Affiliation:
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama223-8522, Japan
Kenta Bito
Affiliation:
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama223-8522, Japan
Terumitsu Hasebe
Affiliation:
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama223-8522, Japan Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-cho, Hachioji-shi, Tokyo192-0032, Japan
Tomohiro Matsumoto
Affiliation:
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama223-8522, Japan Department of Radiology, Tokai University Hachioji Hospital, Tokai University School of Medicine, 1838 Ishikawa-cho, Hachioji-shi, Tokyo192-0032, Japan
Atsushi Hotta*
Affiliation:
Department of Mechanical Engineering, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama223-8522, Japan
*
#Corresponding author: hotta@mech.keio.ac.jp
Get access

Abstract

Embolic beads for transarterial chemoembolization (TACE) should possess radiopacity and biodegradability at the same time, to be visualized in a body under fluoroscopy and CT scanning to avoid complicating disease. In this study, we fabricated radiopaque and biodegradable beads composed of Lipiodol (LPD) (ethiodized oil) and polycaprolactone (PCL), a biocompatible and biodegradable polymer. LPD/PCL beads were first fabricated with a home-made microfluidic device. By changing the flow-rate ratio in the microfluidic device, the mean diameter of LPD/PCL beads could be well controlled. The radiopacity was evaluated by the fluoroscopic imaging and the CT number measurements. Furthermore, the biodegradability was evaluated by collecting the weight loss data of LPD/PCL immersed in lipase/PBS solution and PBS. The results showed that LPD/PCL beads obtained in this study had sufficient radiopacity and biodegradability, which would be an alternative embolic agent for TACE.

Type
Articles
Copyright
Copyright © Materials Research Society 2019 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

*

These authors contributed equally to this paper.

References

Duran, R., Sharma, K., Dreher, M. R., Ashrafi, K., Mirpour, S., Lin, M., Schernthaner, R. E., Schlachter, T. R., Tacher, V., Lewis, A. L., Willis, S., Hartog, M., Radaelli, A., Negussie, A. H., Wood, B. J., Geschwind, J. H., Theranostics 6, 28-39 (2016).CrossRefGoogle Scholar
Yadav, A. V., Mote, H. H., Indian J. Pharm. Sci. 70, 170-174 (2008).CrossRefGoogle Scholar
Woei, K., Hutmacher, D. W., Schantz, J. T., Seng, C., Too, H. P., Chye, T., Phan, T. T. and Teoh, S. H., Tissue Eng . 7, 441-455 (2001).Google Scholar
Miyai, T., Ito, A., Tamazawa, G., Matsuno, T., Sogo, Y., Nakamura, C., Yamazaki, A. and Satoh, T., Biomaterials 29, 350-358 (2008).CrossRefGoogle Scholar
Bouquey, M., Serra, C., Berton, N., Prat, L. and Hadziioannou, G., Chem. Eng. J. 135, S93-S98 (2008).CrossRefGoogle Scholar
Ashrafi, K., Tang, Y., Britton, H., Domenge, O., Blino, D., Brushby, A. J., Shuturminska, K., Hartog, M., Radaelli, A., Negussie, A. H., Mikhail, A. S., Woods, D. L., Krishnasamy, V., Levy, E. B., Wood, B. J., Willis, S. L., Dreher, M. R., Lewis, A. L., J. Controlled Release. 250, 36-47 (2017).CrossRefGoogle Scholar
Li, S., Garreau, H., Pauvert, B., McGrath, J., Toniolo, A. and Vert, M., Biomacromolecules 3, 525-530 (2002).CrossRefGoogle Scholar
Blaine, G., Lancet . 2, 427-429 (1951).CrossRefGoogle Scholar