Determining Canine Blood and Human Blood Composition by Congealing Microliter Drops into Homogeneous Thin Solid Films (HTSFs) via HemaDrop™

Published online by Cambridge University Press:  11 July 2017

Yash Pershad*
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A. BASIS Scottsdale, 10400 N 128th St, Scottsdale, AZ, U.S.A
Nicole Herbots
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A. SiO2 Innovates, Tempe, AZ 85282-3972, U.S.A.
Grady Day
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A. BASIS Scottsdale, 10400 N 128th St, Scottsdale, AZ, U.S.A
Ryan van Haren
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A.
Shawn Whaley
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A. SiO2 Innovates, Tempe, AZ 85282-3972, U.S.A.
Alvaro Martinez
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A.
Sabrina Suhartono
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A.
Robert Culbertson
Affiliation:
Department of Physics, Arizona State University, P.O. Box 85787-1504, Tempe, AZ, U.S.A.
Mark Mangus
Affiliation:
LeRoy Eyring Center for Solid State Sciences, Arizona State University, P.O. Box 85787-1704 Tempe, AZ, U.S.A
Barry Wilkens
Affiliation:
LeRoy Eyring Center for Solid State Sciences, Arizona State University, P.O. Box 85787-1704 Tempe, AZ, U.S.A
*
*(Email: ypershad@asu.edu)
Get access

Abstract

Accurate analysis of microliter blood samples can improve patient care during medical testing and forensics. Patients can suffer from anemia due to the larger volume required for blood tests, 7 milliliters per vial. Attempts at analysis of nanoliter blood samples by Theranos have systematic errors > 10%, higher than medically acceptable thresholds. Our research aims to analyze composition of microliters of blood. This research investigates accuracy of analyzing blood via HemaDrop™, a patented technique to create a Homogenous Thin Solid Film (HTSF) on super-hydrophilic and hyper-hydrophilic surfaces with 5 microliter droplets of blood. To investigate HemaDrop™’s accuracy, Ion Beam Analysis (IBA) is conducted on dried blood spots (DBS) and HTSFs from congealed blood drops on HemaDrop™-treated samples. HTSFs are observed via optical microscopy to compare uniformity, precipitation, and phase separation. DBSs and HTSFs are compared via optical microscopy for canine blood and human blood. After drying uncoated samples, canine and human blood DBSs exhibit cratering, phase separation, and lack of uniformity. Conversely, HTSFs are uniform, exhibiting no cratering and little phase separation. Next, IBA demonstrates that HTSFs of canine and human blood solidified on super-hydrophilic and hyper-hydrophilic coatings yield spectra where species and electrolytes can be identified, unlike on DBSs. The damage curve method enables extracting accurate blood composition for elements, accounting for IBA damage. Relative error in blood elemental composition is within the 10% medical threshold. While both produced films within the 10% threshold, hyper-hydrophilic coatings eliminated phase separation from serum observed in HTSFs on super-hydrophilic coatings. HemaDrop™ provides consistent measurements independent of sample, showing HTSFs from µL blood drops are uniform, reproducible, and free of phase separation. Thus, HemaDrop™ allows for analysis in vacuum from congealed blood drops and expands the range of techniques to identify elements and molecules.

Type
Articles
Copyright
Copyright © Materials Research Society 2017 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Buettner, Johannes, in Senses, Sensors and Systems, (Imprint unknown, Basel, 2004).Google Scholar
Zhi, M., Ding, E. L., Theisen-Toupal, J., Whelan, J., Arnaout, R., PLoS ONE 8, e78962 (2013).Google Scholar
van der Bom, J. G., Cannegieter, S. C., JTH, 13, 1157 (2015).Google Scholar
Salisbury, A. C., Arch. Intern. Med., 171, 1646 (2011).Google Scholar
Thakkar, R. N., Kim, D., et al. ., Am. J. Clin. Pathol., 143, 393 (2015).Google Scholar
Kidd, B. A., Hoffman, G., Zimmerman, N., Li, L., Morgan, J. W., Glowe, P. K., Botwin, G. J., Parekh, S., et al. ., J. Clin. Invest., 126, 1734 (2016).Google Scholar
Greer, John P., in Wintrobe’s Clinical Hematology, (Lippincott Williams & Wilkins, Philadelphia, 2014).Google Scholar
Pershad, Y., Herbots, N., et al. ., MRS Adv. 1(29), 21332139 (2016).Google Scholar
Mukhopadhyay, Sharmila M. , in Sample Preparation for Microscopic and Spectroscopic Characterization of Solid Surfaces, (John Wiley & Sons, Inc., Hoboken, 2003) p. 377411 . Google Scholar
Xing, Q., Herbots, N., Hart, M., Bradley, J., Wilkens, B.J., Sell, D.A., Sell, C.H., et al. ., Applic. of Accel. in Res.. and Ind. AIP Conf. Proc. 1336, 201207 (2011). Google Scholar
Dar, K., Williams, T., Aitken, R., Woods, K. L., and Fletcher, S., BMJ 310, 24 (1995).Google Scholar
Fan, R., Vermesh, O., Srivastava, A., , B. K. et al. ., Nat. Biotechnol., 26, 1373 (2008).Google Scholar