Extract

Multiphoton fluorescence excitation imaging is an optical sectioning technique for fluorescence microscopy. At very high photon densities, two or more photons may coordinately excite an energy transition in a fluorophore that corresponds to the sum of the energies of the individual photons. by this means, a fluorophore may be excited by a wavelength that is considerably longer than its single photon excitation wavelength. Ultra-fast pulsed (femtosecond) lasers can produce the peak power densities in the focal volume of an objective lens needed to provide sufficient 2- or 3- photon excitation events for imaging. The use of short-pulse lasers provides the high peak powers necessary for imaging yet with modest mean power levels that do not thermally damage biological specimens. Production of multiphoton events depends on the square of photon density for 2-photon excitation and the cube of photon density for 3-photon excitation. The power density therefore rapidly falls off away from the focal volume of an objective lens, thereby confining fluorescence excitation to the focal volume.

Type
Biological Applications of Multi-photon Excitation Fluorescence Imaging
Copyright
Copyright © Microscopy Society of America 1997

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Denk, W., Strickler, J. H., Webb, W. W., Science 248, 73 (1990). Pawley, J. B. (Ed.), Handbook of Biological Confocal Microscopy 2nd. edition, Plenum Press, New York (1995).Google Scholar
2.Wokosin, D.L., Centonze, V.E., White, J.G., Hird, S.N., Sepsenwol, S., Malcolm, G.P.A., Maker, G.T. and Ferguson, A.I.. Proceedings SPIE 2678, 38 (1996a).10.1117/12.239552CrossRefGoogle Scholar
3.Wokosin, D.L., Centonze, V.E., Sarah, Crittenden and White, J.G.. Bioimaging 4, 208 (1996b).10.1002/1361-6374(199609)4:3<208::AID-BIO11>3.3.CO;2-A3.3.CO;2-A>CrossRef3.3.CO;2-A>Google Scholar
4. This work was supported by NIH Grants P41-RR00570 and RO1 GM52454-02Google Scholar