Hostname: page-component-77c89778f8-cnmwb Total loading time: 0 Render date: 2024-07-16T10:31:36.349Z Has data issue: false hasContentIssue false

Expert System for EPMA

Published online by Cambridge University Press:  02 July 2020

C. Fournier
Affiliation:
ISTEEM. CNRS, Université de Montpellier II, Sciences et Techniques du Languedoc, PI. E. Bataillon, 34095, Montpellier Cedex 5, France
C. Merlet
Affiliation:
ISTEEM. CNRS, Université de Montpellier II, Sciences et Techniques du Languedoc, PI. E. Bataillon, 34095, Montpellier Cedex 5, France
P.F. Staub
Affiliation:
CAMECA, 103 bd St Denis, BP 6, 92403 Courbevoie Cedex, France
O. Dugne
Affiliation:
CEA VALRHO, DCC/DTE/SIM, BP 111, 26702, Pierrelatte Cedex, France
Get access

Extract

Analysis parameters for an electron microprobe are numerous, and the accuracy of the quantitative analysis is very sensitive to the selection of these experimental conditions. The expert system intends to optimize the choice of each analysis parameter as well as to automate the phases of a quantitative analysis on all kinds of materials. To summarise, the aim of the expert system is to simplify the procedures, improve the accuracy of results and control the analysis time. The figure 1 illustrates the various stages of the expert system.

The starting point of the expert system is an interactive questionnaire concerning the sample,( ie, what is already known), and about the expectations on the analysis,( ie, the accuracy of the results and/or the duration of the analysis required by the operator). Then, the expert system performs a semi-quantitative analysis on the sample. Based on the acquisition of a wavelength qualitative spectrum, this method is a way to obtain the sample composition in a short time with the advantages of the WDS system, and with a reasonable accuracy.

Type
Mas Celebrates: Fifty Years of Electron Probe Microanalysis
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Fournier, C., Merlet, C., Fialin, M. and Dugne, O., J. Anal. At. Spectrom., 14 (1999), in press.CrossRefGoogle Scholar
2.Wernisch, J. and Röharbacher, K., Mickrochim. Acta, 15 (1998), 307.Google Scholar
3.Reed, S.J.B., Mickrochim. Acta., 15 (1998), 29.Google Scholar
4.Merlet, C.and Bodinier, J.L., Chem. Geol, 83 (1990), 55.CrossRefGoogle Scholar