Hostname: page-component-848d4c4894-4hhp2 Total loading time: 0 Render date: 2024-05-14T22:47:40.406Z Has data issue: false hasContentIssue false

Atomic Structure of La067Ca0.33MnO3 Thin Films on LaAlO3

Published online by Cambridge University Press:  02 July 2020

H-J. Gao
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN37831-6030
C.L. Chen
Affiliation:
Department of Physics and the Texas Center for Superconductivity, University of Houston, Houston, Texas77204
X. Fan
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN37831-6030
M. Kim
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN37831-6030
S.Y. Chen
Affiliation:
Department of Physics and the Texas Center for Superconductivity, University of Houston, Houston, Texas77204
C.W. Chu
Affiliation:
Department of Physics and the Texas Center for Superconductivity, University of Houston, Houston, Texas77204
S.J. Pennycook
Affiliation:
Solid State Division, Oak Ridge National Laboratory, Oak Ridge, TN37831-6030
Get access

Extract

Thin films of doped perovskite manganites of the type R1-X AxMnO3-y are currently become the focus of intense theoretical and experimental research due to their promising technological implications. However, the microstructure of the film and the interface structure at the atomic level remains unclear. In this report, we will present the atomic structure of the film/substrate interface and the microstructure of the film using a combination of transmission electron microscopy (TEM), Z-contrast scanning transmission microscopy (STEM), and electron energy loss spectroscopy (EELS).

The La0.67Ca0.33MnO3 (LCMO) samples were grown on (001) LaA1O3 (LAO) using pulsed laser deposition. X-ray diffraction indicated the films to be oriented with the [001] directions parallel to the <001> directions of the pseudo-cubic perovskite LAO. Rocking curve measurements using the (002) reflection from the film indicated a full width half maximum of less than 0.3°. A Philips EM-400 electron microscope at 100 kV and a VG HB603 STEM at 300 kV were employed for sample analysis.

Type
Ceramics & Minerals
Copyright
Copyright © Microscopy Society of America

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

References:

1.Jin, S., et al., Science 264, 413(1994).CrossRefGoogle Scholar
2.von Helmholt, R., et al., Phys. Rev. Lett. 71, 2331(1993).CrossRefGoogle Scholar
3.Pennycook, S. J. and Nellist, P.D., in: Impact of Electron and Scanning Probe Microscopy on Materials Research, Ed. by Rickerby, D.G., Valdre, U. and Valdre, G., Kluwer Academic Publisher, The Netherlands, (1999), P. 161.CrossRefGoogle Scholar
4.Gao, H-J., et al., Appl. Phys. Lett, (to be published).Google Scholar