Hostname: page-component-5c6d5d7d68-txr5j Total loading time: 0 Render date: 2024-08-15T10:16:43.292Z Has data issue: false hasContentIssue false

A superconducting galvanometer

Published online by Cambridge University Press:  24 October 2008

A. B. Pippard
Affiliation:
Rolay Society Mond LaboratoryCambridge
G. T. Pullan
Affiliation:
Rolay Society Mond LaboratoryCambridge

Abstract

A superconducting tangent galvanometer suitable for the measurement of thermoelectric voltages in circuits of resistance about 10−7 ohm is described. The inductance has been kept low by the use of only a single turn in each of the deflecting coils, but a high sensitivity has been attained by reducing the controlling field to about 0·01 gauss. The theory of operation of such a galvanometer in circuits of low resistance is discussed; the actual behaviour of the instrument is in satisfactory agreement with the theory. The galvanometer will detect a current of 10−5 A. corresponding to an e.m.f. of 10−12 V.

Type
Research Article
Copyright
Copyright © Cambridge Philosophical Society 1952

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

(1)Grayson, Smith H. and Tarr, F. G. A.Trans. roy. Soc. Can. (3), 29/III (1935), 23.Google Scholar
(2)Grayson, Smith H., Mann, K. C. and Wilhelm, J. O.Trans. roy. Soc. Can. (3), 30/III (1936), 13.Google Scholar
(3)Preston-Thomas, H.J. sci. Instrum. 26 (1949), 381.CrossRefGoogle Scholar