Skip to main content Accessibility help
×
Home

In vivo bone regeneration analysis of trilayer coated 316L stainless steel implant in rabbit model

  • Priyanka Majee (a1), Shampa Dhar (a1), P.K. Mitra (a1), Lalzawmliana V. (a2), Samit Kumar Nandi (a2), Piyali Basak (a3) and Biswanath Kundu (a4)...

Abstract

To increase the corrosion prevention of stainless steel implant and fast recovery due to new bone-cell formation at the orthopedic implant site, in the present investigation, a trilayered (with bioceramic interlayer sandwiched between innermost passivated surface and outermost polymer coating) 316L stainless steel (SS) implant was designed and investigated. It was inferred that this new designed implant invokes faster and more bone-cell formation than uncoated commercially available 316L SS implants. Faster bone-cell formation at the coated implant site reduces the initial threat of implant corrosion. The electrochemical corrosion study proved that this model of coated implants is able to prevent corrosion up to 90% better than uncoated commercially available 316L SS. Subsequently, preclinical studies in the rabbit bone defect model (which included histology, radiology, fluorochrome labeling, push-out test, and scanning electron microscopy taken after 45 and 90 days) proved higher rate of new bone tissue formation and better push-out strength between tissue in contact and the coated implant. The toxicological study of vital organs like liver, kidney, and heart also exhibited no abnormality. The outcome of the experimentations indicates suitability of this trilayered 316L SS implant for bone repair and healing.

Copyright

Corresponding author

a)Address all correspondence to these authors. e-mail: samitnandi1967@gmail.com

References

Hide All
1.Holzapfel, B.M., Reichert, J.C., Schantz, J-T., Gbureck, U., Rackwitz, L., Noth, U., Jakob, F., Rudert, M., Groll, J., and Hutmacher, D.W.: How smart do biomaterials need to be? A translational science and clinical point of view. Adv. Drug Delivery Rev. 65, 581 (2013).
2.Thamaraiselvi, T. and Rajeswari, S.: Biological evaluation of bioceramic materials—A review. Trends Biomater. Artif. Organs 18, 9 (2004).
3.Vallet-Regi, M.: Ceramics for medical applications. J. Chem. Soc., Dalton Trans., 97 (2001).
4.Rieger, W., Leyen, S., Kobel, S., and Weber, W.: The use of bioceramics in dental and medical applications. Digital Dent. News 3, 6 (2009).
5.Hench, L.L. and Wilson, J.: An Introduction to Bioceramics (World Scientific, Singapore, 1993).
6.Lin, X., De Groot, K., Wang, D., Hu, Q., Wismeijer, D., and Liu, Y.: Suppl 1-M4: A review paper on biomimetic calcium phosphate coatings. Open Biomed. Eng. J. 9, 56 (2015).
7.LeGeros, R.Z.: Properties of osteoconductive biomaterials: Calcium phosphates. Clin. Orthop. Relat. Res. 395, 81 (2002).
8.Zhang, B.G.X., Myers, D.E., Wallace, G.G., Brandt, M., and Choong, P.F.M.: Bioactive coatings for orthopaedic implants - Recent trends in development of implant coatings. Int. J. Mol. Sci. 15, 11878 (2014).
9.Babu, N.R., Manwatkar, S., Rao, K.P., and Kumar, T.S.S.: Bioactive coatings on 316L stainless steel implants. Trends Biomater. Artif. Organs 17, 43 (2004).
10.He, J., Huang, T., Gan, L., Zhou, Z., Jiang, B., Wu, Y., Wu, F., and Gu, Z.: Collagen-infiltrated porous hydroxyapatite coating and its osteogenic properties: In vitro and in vivo study. J. Biomed. Mater. Res., Part A 100, 1706 (2012).
11.Saran, N., Zhang, R., and Turcotte, R.E.: Osteogenic protein-1 delivered by hydroxyapatite-coated implants improves bone ingrowth in extracortical bone bridging. Clin. Orthop. Relat. Res. 469, 1470 (2011).
12.Kargupta, R., Bok, S., Darr, C.M., Crist, B.D., Gangopadhyay, K., Gangopadhyay, S., and Sengupta, S.: Coatings and surface modifications imparting antimicrobial activity to orthopedic implants. Wiley Interdiscip. Rev.: Nanomed. Nanobiotechnol. 6, 475 (2014).
13.Bumgardner, J.D., Wiser, R., Gerard, P.D., Bergin, P., Chestnutt, B., Marini, M., Ramsey, V., Elder, S.H., and Gilbert, J.A.: Chitosan: Potential use as a bioactive coating for orthopaedic and craniofacial/dental implants. J. Biomater. Sci., Polym. Ed. 14, 423 (2003).
14.Correlo, V.M., Boesel, L.F., Bhattacharya, M., Mano, J.F., Neves, N.M., and Reis, R.L.: Hydroxyapatite reinforced chitosan and polyester blends for biomedical applications. Macromol. Mater. Eng. 290, 1157 (2005).
15.Mishra, S.K. and Kannan, S.: Development, mechanical evaluation and surface characteristics of chitosan/polyvinyl alcohol based polymer composite coatings on titanium metal. J. Mech. Behav. Biomed. Mater. 40, 314 (2014).
16.Zankovych, S., Diefenbeck, M., Bossert, J., Muckley, T., Schrader, C., Schmidt, J., Schubert, H., Bischoff, S., Faucon, M., and Finger, U.: The effect of polyelectrolyte multilayer coated titanium alloy surfaces on implant anchorage in rats. Acta Biomater. 9, 4926 (2013).
17.Anderson, J.M.: Biological responses to materials. Annu. Rev. Mater. Res. 31, 81 (2001).
18.Wieslander, A.P., Nordin, M.K., Hansson, B., Baldetorp, B., and Kjellstrand, P.T.T.: In vitro toxicity of biomaterials determined with cell density, total protein, cell cycle distribution and adenine nucleotides. Biomater. Artif. Cells Immobil. Biotechnol. 21, 63 (1993).
19.Majee, P. and Mitra, P.K.: Preventive coating of tri-calcium phosphate (TCP) on implantable 304L SS. Icastor J. Eng. 8, 117 (2015).
20.Kokubo, T. and Takadama, H.: How useful is SBF in predicting in vivo bone bioactivity? Biomaterials 27, 2907 (2006).
21.Bishop, J.A., Palanca, A.A., Bellino, M.J., and Lowenberg, D.W.: Assessment of compromised fracture healing. J. Am. Acad. Orthop. Surg. 20, 273 (2012).
22.Chew, K-K., Zein, S.H.S., and Ahmad, A.L.: The corrosion scenario in human body: Stainless steel 316L orthopaedic implants. Nat. Sci. 4, 184 (2012).
23.Kamachimudali, U., Sridhar, T.M., and Raj, B.: Corrosion of bio implants. Sadhana 28, 601 (2003).
24.Kim, J.J. and Young, Y.M.: Study on the passive film of type 316 stainless steel. Int. J. Electrochem. Sci. 8, 11847 (2013).
25.Bosco, R., Van Den Beucken, J., Leeuwenburgh, S., and Jansen, J.: Surface engineering for bone implants: A trend from passive to active surfaces. Coatings 2, 95 (2012).
26.Thamaraiselvi, T.V. and Rajeswari, S.: Electrochemical behaviour of alkali treated and hydroxyapatite coated 316 LVM. Trends Biomater. Artif. Organs 18, 242 (2005).
27.Dhar, S. and Mitra, P.K.: Electrochemical behaviour of hydroxyapatite coatings on phosphate passivated 316L stainless steel in Ringer’s solution. Icastor J. Eng. 5, 155 (2012).
28.Dhar, S., Mitra, P.K., and Duari, B.: Corrosion behaviour of hydroxyapatite coatings on borate and phosphate-passivated 316L stainless steel in Ringer’s solution. Paint India 62, 63 (2012).
29.Arinzeh, T.L., Peter, S.J., Archambault, M.P., Van Den Bos, C., Gordon, S., Kraus, K., Smith, A., and Kadiyala, S.: Allogeneic mesenchymal stem cells regenerate bone in a critical-sized canine segmental defect. J. Bone Jt. Surg. Am. 85, 1927 (2003).
30.van Gaalen, S.M., Kruyt, M.C., Geuze, R.E., de Bruijn, J.D., Alblas, J., and Dhert, W.J.A.: Use of fluorochrome labels in in vivo bone tissue engineering research. Tissue Eng., Part B 16, 209 (2010).
31.Kovar, J.L., Xu, X., Draney, D., Cupp, A., Simpson, M.A., and Olive, D.M.: Near-infrared-labeled tetracycline derivative is an effective marker of bone deposition in mice. Anal. Biochem. 416, 167 (2011).
32.Dahners, L.E. and Bos, G.D.: Fluorescent tetracycline labeling as an aid to debridement of necrotic bone in the treatment of chronic osteomyelitis. J. Orthop. Trauma 16, 345 (2002).
33.Gibson, C.J., Thornton, V.F., and Brown, W.A.B.: Incorporation of tetracycline into impeded and unimpeded mandibular incisors of the mouse. Calcif. Tissue Int. 26, 29 (1978).
34.Shi, Z., Neoh, K.G., Kang, E.T., Poh, C., and Wang, W.: Bacterial adhesion and osteoblast function on titanium with surface-grafted chitosan and immobilized RGD peptide. J. Biomed. Mater. Res., Part A 86, 865 (2008).
35.Di Martino, A., Sittinger, M., and Risbud, M.V.: Chitosan: A versatile biopolymer for orthopaedic tissue-engineering. Biomaterials 26, 5983 (2005).
36.Ohara, N., Hayashi, Y., Yamada, S., Kim, S-K., Matsunaga, T., Yanagiguchi, K., and Ikeda, T.: Early gene expression analyzed by cDNA microarray and RT-PCR in osteoblasts cultured with water-soluble and low molecular chitooligosaccharide. Biomaterials 25, 1749 (2004).
37.Brunski, J.B., Puleo, D.A., and Nanci, A.: Biomaterials and biomechanics of oral and maxillofacial implants: Current status and future developments. Int. J. Oral Maxillofac. Implants 15, 15 (1999).
38.Kempen, D.H.R., Lu, L., Heijink, A., Hefferan, T.E., Creemers, L.B., Maran, A., Yaszemski, M.J., and Dhert, W.J.A.: Effect of local sequential VEGF and BMP-2 delivery on ectopic and orthotopic bone regeneration. Biomaterials 30, 2816 (2009).
39.Johansson, C.B., Han, C.H., Wennerberg, A., and Albrektsson, T.: A quantitative comparison of machined commercially pure titanium and titanium–aluminum–vanadium implants in rabbit bone. Int. J. Oral Maxillofac. Implants 13, 315 (1998).
40.Wang, Z. and Hu, Q.: Preparation and properties of three-dimensional hydroxyapatite/chitosan nanocomposite rods. Biomed. Mater. 5, 045007 (2010).

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed