Hostname: page-component-848d4c4894-8bljj Total loading time: 0 Render date: 2024-06-17T07:46:52.805Z Has data issue: false hasContentIssue false

VP184 A Cost Analysis Of Flash Glucose Monitoring Systems In Veneto Region

Published online by Cambridge University Press:  12 January 2018

Rights & Permissions [Opens in a new window]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.
INTRODUCTION:

A novel, sensor-based, factory-calibrated Flash Monitoring System (FMS) has recently proved to be an effective alternative to conventional self-monitoring of blood glucose (SMBG) in patients affected by type 1 and type 2 diabetes. The 14-days adhesive sensor, that continuously measures glucose levels in the interstitial fluid, can transfer glucose levels data to a handheld reader or a smartphone equipped with a specific medical app. The uptake of the new technology has been limited so far, because of its high costs. A cost analysis has been conducted to identify the optimal target population of introducing FSM in Veneto.

METHODS:

The model was designed with a 1-year time horizon for patients with diabetes using intensive insulin in Veneto region. The costs of the new technology was estimated using inputs from the two main randomized controlled trials (the IMPACT study and the REPLACE study) published in the international literature, Regional evidence-based guidelines and administrative database. Resource utilization included strips, lancets, needles, sensors, distribution and patients training. Regional unit costs were adopted.

RESULTS:

FSM has not shown so far relevant and statically significant benefits in terms of severe adverse events’ reduction. Estimated yearly costs for a FSM user included glucose monitoring, technology training and distribution costs, for a total of EUR1277 per patient. The new technology has been shown to be affordable in diabetic patients with i) 4years<age<18years, ii) continuous subcutaneous insulin infusion and iii) ≥5 blood glucose monitoring per day.

CONCLUSIONS:

The Veneto Region should carefully consider prescribing extension to other diabetic patients categories, since the high cost of the new technology. A strict prescribing monitoring is strongly recommended with the aim of ensuring appropriateness and avoiding overspending.

Type
Vignette Presentations
Copyright
Copyright © Cambridge University Press 2018