Hostname: page-component-848d4c4894-4rdrl Total loading time: 0 Render date: 2024-06-25T04:57:35.524Z Has data issue: false hasContentIssue false

New temperature reference cells for calibrating CSPRTs under adiabatic conditions

Published online by Cambridge University Press:  02 December 2014

Get access

Abstract

Two new miniature metallic sealed-cells containing the triple point of water, WTP (273.16 K) and the triple point of mercury, HgTP (234.3156 K) have been constructed for the realization of the International Temperature Scale of 1990 (ITS-90) at the National Institute of Standards (NIS-Egypt). The new cells will provide facilities for the calibration of Capsule-type Standard Platinum Resistance Thermometers (CSPRTs). The two cells will complete a multi-cells compartment in order to calibrate CSPRTs in one single experiment. The multi-cells compartment contains two other cells; the triple point of argon (83.8058 K) and the triple point of oxygen (54.3584 K) that has been already developed and characterized before [M.G. Ahmed, Y. Hermier, Development of an adiabatic calorimeter in the range 54 K–273 K in frame of a scientific collaboration LNE-NIS, AIP Conf. Proc. 1552, 153 (2013)]. The system can calibrate two CSPRTs at once. The compartment is accommodated in an adiabatic calorimeter. With a special technique, the calorimeter could go down to a temperature of 52 K using liquid nitrogen and special pumping system.

Type
Research Article
Copyright
© EDP Sciences 2014

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Ahmed, M.G., Hermier, Y., Development of an adiabatic calorimeter in the range 54 K–273 K in frame of a scientific collaboration LNE-NIS, AIP Conf. Proc. 1552, 153 (2013) CrossRefGoogle Scholar
Ahmed, M.G., El Matarawy, A.A., An adiabatic calorimeter for calibrating capsule type thermometers (CSPRTs) in the range 54 K to 273 K, Int. J. Metrol. Qual. Eng. 3, 8587 (2012) CrossRefGoogle Scholar
Preston-Thomas, H., The International temperature scale of 1990 (ITS-90), Metrologia 27, 310 (1990) CrossRefGoogle Scholar
Sparasci, F., Pitre, L., Hermier, Y., Realization of the triple point of water in metallic sealed cells at the LNE-INM/CNAM: A progress report, Int. J. Thermophys. 29, 825835 CrossRef
L. Lipinski, H. Manuszkiewicz, A. Szmyrka-Grzebyk, P.P.M. Steur, P. Marcarino, Comparison of temperature values of the mercury triple point realised in miniature and conventional cells, in Conf. Proc. Tempmeko, pp. 441–446 (2001)
Hermier, Y., Pitre, L., Geneville, C., Vergé, A., Bonnier, G., Head, D.I., Fellmuth, B., Wolber, L., Szmyrka-Grzebyk, A., Lipinski, L., de Groot, M.J., Peruzzi, A., A new generation of multicells for cryogenic fixed points at BNM/INM, AIP Conf. Proc. 684, 179 (2003) CrossRefGoogle Scholar
F. Pavese, B. Fellmuth, D. Head, Y. Hermier, A. Peruzzi, A. Szmyrka Grzebyk, L. Zanin, in temperature: Its Measurement and Control in Science and Industry (New York, 2003), Vol. 7, Part 1, pp. 161–166
M.G. Ahmed, M.R. Moussa, Performance of Mercury Triple-Point Cells Made in NIS-Egypt, Proc. of 15th International Metrology Congress (Paris-France, 2011)