Hostname: page-component-76fb5796d-22dnz Total loading time: 0 Render date: 2024-04-26T04:34:55.523Z Has data issue: false hasContentIssue false

Measurements of UV-A radiation and hazard limits from some types of outdoor lamps

Published online by Cambridge University Press:  02 December 2014

S. Reda
Affiliation:
Photometry and Radiometry division, National Institute for Standards (NIS), Giza, Egypt
Get access

Abstract

Illumination using artificial light sources is common in these days. Many manufactures are paying for the design of lamps depending on high efficacy and low UV hazards. This research is focusing on the most useable lamps in the Egyptian markets; high pressure mercury (HPM), metal Halide (MH), and high pressure sodium (HPS). A set up for relative spectral power distribution based on single monochromator and UVA silicon detector for absolute irradiance measurements are used. The absolute irradiance in (W/m2) in UVA region of the lamps and their accompanied standard uncertainty are evaluated.

Type
Research Article
Copyright
© EDP Sciences 2014

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

C. De Cusatis, Handbook of Applied Photometry (Optical Society of America, Poughkeepsie, New York, 1994)
F. Grum, R. Becherer, Optical Radiation Measurements (Academic Press, Radiometry, 1979), Vol. 1
Lighting Associates, Inc, http://www.lightingassociates.org
E.E.M. El-moghazy, A technical study of the development of working standard lamps for lighting applications, Doctoral thesis, College of Woman, Ein Shames university, 2012
Photobiological safety of lamps and lamp systems, standard CIE S 009/E (2002)
Sharma, P., Jaiswal, V.K., Kandpal, H.C., Ultraviolet radiation emitted by compact fluorescence lamps, J. Metrol. Soc. India (MAPAN) 24, 183191 (2009) Google Scholar
A. Abd-Elmageed, Detector-based traceability chain for spectral irradiance using tunable laser based facility at PTB, Doctoral thesis, Braunschweig University, Germany, 2011
IES Guide to Lamp Seasoning, J. Illuminating Engineering society, IES LM-54-12 (2012)
Reda, S.M., Abd-Elmageed, A.-E.A., On the use of spectral lamp lines in the Monochromator Calibration, Trends in Advanced Science and Engineering, TASE 4, 2225 (2012) Google Scholar
International Organization for Standardization (ISO), Guide to the expression of uncertainty in measurement (1993)
United Kingdom Accreditation Service (UKAS), The expression of uncertainty and confidence in measurement, 2nd edn. (2007)