Skip to main content Accessibility help
×
Home

Measurement of Patient Hand Hygiene in Multiorgan Transplant Units Using a Novel Technology: An Observational Study

  • Jocelyn A. Srigley (a1), Colin D. Furness (a2) and Michael Gardam (a3)

Abstract

Objective.

Healthcare worker hand hygiene is known to prevent healthcare-associated infections, but there are few data on patient hand hygiene despite the fact that nosocomial pathogens may be acquired by patients via their own unclean hands. The purpose of this study was to measure patient hand hygiene behavior in the hospital after visiting a bathroom, before eating, and on entering and leaving their rooms

Design.

Cross-sectional study.

Setting.

Acute care teaching hospital in Canada.

Patients.

Convenience sample of 279 adult patients admitted to 3 multiorgan transplant units between July 2012 and March 2013.

Methods.

Patient use of alcohol-based hand rub and soap dispensers was measured using an ultrasound-based real-time location system during visits to bathrooms, mealtimes, kitchen visits, and on entering and leaving their rooms.

Results.

Overall, patients performed hand hygiene during 29.7% of bathroom visits, 39.1% of mealtimes, 3.3% of kitchen visits, 2.9% of room entries, and 6.7% of room exits.

Conclusions.

Patients appear to perform hand hygiene infrequently, which may contribute to transmission of pathogens from the hospital environment via indirect contact or fecal-oral routes.

Infect Control Hosp Epidemiol 2014;35(11):1336–1341

Copyright

Corresponding author

711 Concession Street, M1-Room 8, Hamilton, ON L8V 1C3, Canada (srigley@hhsc.ca).

References

Hide All
1. World Health Organization (WHO). WHO Guidelines on Hand Hygiene in Health Care. Geneva: World Health Organization, 2009.
2. Banfield, KR, Kerr, KG. Could hospital patients’ hands constitute a missing link? J Hosp Infect 2005;61:183188.
3. Randle, J, Arthur, A, Vaughan, N. Twenty-four-hour observational study of hospital hand hygiene compliance. J Hosp Infect 2010;76:252255.
4. Mattam, K, Al-Badawi, T, King, S, Guleri, A. The missing link in the health-care associated infection acquisition cycle: an innovative patient hand-hygiene audit led by doctors at a tertiary cardiac centre in northwestern England. Clin Microbiol Infect 2012;18:809.
5. Haas, JP, Larson, EL. Measurement of compliance with hand hygiene. J Hosp Infect 2007;66:614.
6. Ontario Provincial Infectious Diseases Advisory Committee. Best Practices for Hand Hygiene in All Health Care Settings. Toronto: Queen’s Printer for Ontario, 2010.
7. Curtis, DW, Pino, EJ, Bailey, JM, et al. SMART: an integrated wireless system for monitoring unattended patients. J Am Med Inform Assoc 2008;15:4453.
8. Srigley, JA, Furness, CD, Baker, GR, Gardam, M. Quantification of the Hawthorne effect in hand hygiene compliance monitoring using an electronic monitoring system: a retrospective cohort study. BMJ Qual Saf 2014. doi:10.1136/bmjqs-2014-003080 (electronically published ahead of print).
9. Cheng, VC, Wu, AK, Cheung, CH, et al. Outbreak of human metapneumovirus infection in psychiatric inpatients: implications for directly observed use of alcohol hand rub in prevention of nosocomial outbreaks. J Hosp Infect 2007;67:336343.
10. Gagne, D, Bedard, G, Maziade, PJ. Systematic patients’ hand disinfection: impact on meticillin-resistant Staphylococcus aureus infection rates in a community hospital. J Hosp Infect 2010;75:269272.
11. Zimlichman, E, Henderson, D, Tamir, O, et al. Health care–associated infections: a meta-analysis of costs and financial impact on the US health care system. J Am Med Assoc 2013;173(22):20392046.
12. Boyce, JM. Measuring healthcare worker hand hygiene activity: current practices and emerging technologies. Infect Control Hosp Epidemiol 2011;32:10161028.

Metrics

Altmetric attention score

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed