Hospital Room Sterilization Using Far-Ultraviolet Radiation: A Pilot Evaluation of the Sterilray Device in an Active Hospital Setting

  • Gaurav Varma (a1), Patrice Savard (a2), Christian Coles (a1), Tracy Ross (a3), Karen Carroll (a3), Trish Perl (a2) and Alain Labrique (a1)...

Abstract

Environmental contamination of hospital rooms is well recognized as a reservoir for highly resistant nosocomial pathogens such as methicillin-resistant Staphylococcus aureu (MRSA) and vancomycin-resistant Enterococcus (VRE), which can be transferred to patients through contact with healthcare providers and contaminated surfaces. Numerous studies dedicated to environmental cleaning and disinfection have found promising results with several novel technologies, including vaporized hydrogen peroxide and ultraviolet over-head lighting or wands. We conducted a pilot study of one such device, the Sterilray Disinfection Wand (Healthy Environment Innovations), a handheld ultraviolet (UV) room decontamination wand. The Sterilray device claims to generate UV radiation in the far-UV spectrum (185-230 nm), resulting in the rapid killing of contaminant bacteria. The goal of this pilot was to collect preliminary data on the efficacy of this device in reducing surface contamination, particularly of common nosocomial pathogens, in an active hospital setting.

Copyright

Corresponding author

615 North Wolfe Street E5543, Baltimore, MD 21205 (alabriqu@jhsph.edu)

References

Hide All
1.Weinstein, RA, Hota, B. Contamination, disinfection, and cross-colonization: are hospital surfaces reservoirs for nosocomial infection? Clin Infect Dis 2004;39(8):11821189.
2.Boyce, JM. Environmental contamination makes an important contribution to hospital infection. J Hosp Infect 2007;65:5054.
3.Boyce, JM, Potter-Bynoe, G, Chenevert, C, King, T. Environmental contamination due to methicillin-resistant Staphylococcus aureus: possible infection control implications. Infect Control Hosp Epidemiol 1997;18:622627.
4.Hardy, KJ, Oppenheim, BA, Gossain, S, Gao, F, Hawkey, PM. A study of the relationship between environmental contamination with methicillin-resistant Staphylococcus aureus (MRSA) and patients' acquisition of MRSA. Infect Control Hosp Epidemiol 2006;27(2):127132.
5.Schmidt, MG, Anderson, T, Attaway, HH, Fairey, S, Kennedy, C, Salgado, CD. Patient environment microbial burden reduction: a pilot study comparison of 2 terminal cleaning methods. Am J Infect Control 2012;40:559561.
6.American Air and Water. UVGI Applied during Orthopedic Surgery and the Rate of Infection, http://www.americanairandwater.com /uv-hospitals/UVGI-or-disinfection.pdf. Published 2012. Accessed March 14, 2013.
7.Glendenin, LE. Determination of the energy of beta particles and photons by absorption. Nucleonics 1948;2(1):1232.
8.Neister, SE, inventor. Method and apparatus for sterilizing and disinfecting air and surfaces and protecting a zone from external microbial contamination. 2007. Patent US 2010/0028201.
9.Nerandzic, MM, Cadnum, JL, Eckart, KE, Donskey, CJ. Evaluation of a hand-held far-ultraviolet radiation device for decontamination of Clostridium difficile and other healthcare-associated pathogens. BMC Infect Dis 2012;12(1):120.

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed