Evaluation of environmental cleaning of patient rooms: Impact of different fluorescent gel markers

  • Clare Rock (a1) (a2) (a3), Anping Xie (a2), Jennifer Andonian (a3), Yea-Jen Hsu (a4), Patience Osei (a2), Sara C. Keller (a1), Ayse P. Gurses (a2), Polly Trexler (a3), Lisa L Maragakis (a1) (a2) (a3), Sara E. Cosgrove (a1) (a2) (a3) and for the CDC Prevention Epicenters Program (a1) (a2) (a3) (a4)...

Abstract

In this systematic evaluation of fluorescent gel markers (FGM) applied to high-touch surfaces with a metered applicator (MA) made for the purpose versus a generic cotton swab (CS), removal rates were 60.5% (476 of 787) for the MA and 64.3% (506 of 787) for the CS. MA-FGM removal interpretation was more consistent, 83% versus 50% not removed, possibly due to less varied application and more adhesive gel.

Copyright

Footnotes

Hide All

Cite this article: Rock C, et al. (2019). Evaluation of environmental cleaning of patient rooms: Impact of different fluorescent gel markers. Infection Control & Hospital Epidemiology 2019, 40, 100–102. doi: 10.1017/ice.2018.287

Footnotes

References

Hide All
1. Han, JH, Sullivan, N, Leas, BF, Pegues, DA, Kaczmarek, JL, Umscheid, CA. Cleaning hospital room surfaces to prevent health care–associated infections. Ann Intern Med 2015;163:598607.
2. Kenters, N, Gottlieb, T, Hopman, J, et al. An international survey of cleaning and disinfection practices in the healthcare environment. J Hosp Infect 2018. doi: 10.1016/j.jhin.2018.05.008.
3. Options for evaluating environmental cleaning. Toolkits: Preventing HAIs. Centers for Disease Control and Prevention website. http://www.cdc.gov/hai/toolkits/Evaluating-Environmental-Cleaning.html. Published 2010. Accessed October 13, 2015.
4. Vickery, K, Deva, A, Jacombs, A, Allan, J, Valente, P, Gosbell, IB. Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit. J Hosp Infect 2012;80:5255.
Type Description Title
UNKNOWN
Supplementary materials

Rock et al. supplementary material
Rock et al. supplementary material 1

 Unknown (6.7 MB)
6.7 MB

Metrics

Altmetric attention score

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed