Effects of Ultra High Speed Floor Burnishing on Air Quality in Health Care Facilities

  • Edward A. Schmidt (a1), Bernard M. Cannan (a1), Richard C. Mulhall (a1) and David L. Coleman (a1)

Abstract

Effects of ultra high speed (UHS) floor burnishing upon air quality in health care facilities were evaluated. A 2,000-rpm burnisher can disseminate high-velocity (190 km/hr) dust and microbial particles. A UHS burnisher used with either inadequate or no air restraint produced significant increases (P<0.05) in the levels of airborne dust particles and microorganisms. A UHS burnisher equipped with an air restraint assembly specifically designed for use in health care facilities produced no significant increase (P>0.05) in the levels of airborne dust particles or microorganisms when compared to ambient air levels. The types and distribution of airborne microorganisms isolated from microbial air samples were not unusual nor were they directly influenced by the floor burnishing processes. Furthermore, the UHS floor burnishing process produced a significant reduction (P<0.05 ) in microbial floor contaminants (96%). When the use of UHS floor burnishing is contemplated for productivity improvement and esthetic enhancement, the possible adverse effects on air quality should also be considered.

Copyright

Corresponding author

ServiceMaster Industries, Inc., 2300 Warrenville Road, Downers Grove, IL 60515

References

Hide All
1.Ames, A: Ultra high-speed cleaning & polishing. Cleaning Management 1982; 4:2428.
2.Each, TC: High-speed floor care. Cleaning Management 1979; 9:3237.
3.The road to ultra high-speed floor care. Cleaning Management 1984; 4:6568.
4.Waxes, Polishes, and Floor Finishes Division, Chemical Specialties Manufacturers Association (CSMA): High speed buffing, in: Divisional Program Proceedings, CSMA Technical Reports, 1984; 5:4180.
5.Grover, R: A systems approach to modern floor care. Cleaning Management 1985; 4:4548.
6.Update on floor machines. Cleaning Management 1980; 4:5354.
7.Carr, R: Selecting floor finishes for ultra high speed buffing. Cleaning Management 1984; 4:6061.
8.Netz, SM: Ultra high speeds trigger systems compatibility questions. Sanitary Maintenance 1983; 50:4862.
9.Schmidt, EA, Coleman, DL, Mallison, GF: Improved system for floor cleaning in health care facilities. Appl Environ Microbiol 1984; 47:942946.
10.Centers for Disease Control: Guidelines for hospital environmental control. Infect Control 1981; 3:54.
11.American Hospital Association. Infection Control in the Hospital (ed. 4). Chicago, American Hospital Association, 1979, p 69.

Effects of Ultra High Speed Floor Burnishing on Air Quality in Health Care Facilities

  • Edward A. Schmidt (a1), Bernard M. Cannan (a1), Richard C. Mulhall (a1) and David L. Coleman (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed