Hostname: page-component-8448b6f56d-m8qmq Total loading time: 0 Render date: 2024-04-24T19:26:26.960Z Has data issue: false hasContentIssue false

X-Ray Variability in Active Galaxy Nuclei and Quasars in less than One Day

Published online by Cambridge University Press:  30 March 2016

M. Elvis
Affiliation:
Harvard-Smithsonian Center for Astrophysics Cambridge, Massachusetts, USA.
E. Feigelson
Affiliation:
Harvard-Smithsonian Center for Astrophysics Cambridge, Massachusetts, USA.
R. E. Griffiths
Affiliation:
Harvard-Smithsonian Center for Astrophysics Cambridge, Massachusetts, USA.
J. P. Henry
Affiliation:
Harvard-Smithsonian Center for Astrophysics Cambridge, Massachusetts, USA.
H. Tananbaum
Affiliation:
Harvard-Smithsonian Center for Astrophysics Cambridge, Massachusetts, USA.

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Active galaxy-X-ray sources are well known to be variable on timescales of days to years (Ricketts, et al. 1977, Mushotzky, et al. 1979, Lawrence 1979). Here we present some new data from the Einstein Observatory which shows that these sources also vary in less than one day, on timescales of hours. Large luminosity changes in such short times promise to allow the investigation of the physics of such sources in several new ways. We shall give some examples of how this can be begun. This is only a preliminary report of this work. A full account will be given elsewhere.

The Einstein Observatory (Giacconi, et al. 1979) is capable of exploring this regime of variability because its imaging capability gives it two unique advantages. Firstly, the background rate in one beam area is negligible so that intensity determinations are limited only by Poisson counting statistics. Secondly, the background counts in the remainder of the field can be integrated to give a simultaneous monitor with the same instrument of cosmic ray and background X-ray events. Thus, any peculiarities in detector behaviour, telemetry or software can be traced and separated from real source variations. This is a significant advantage and gives us a great deal more confidence in our results. Many sources do not show variability. For example, in our data, Cen A is constant to ˜ 2% over 1 day.

Type
Joint Discussion
Copyright
Copyright © Cambridge University Press 1980

References

Barr, P., White, N.E., Sanford, P.W. Ives, J.C.: 1977, M.N.R.A.S., 181, 43P.CrossRefGoogle Scholar
Fabian, A.C., Rees, M.J.: 1979 (COSPAR) X-ray Astronomy, p. 381.Google Scholar
Giacconi, R., et al.: 1979, Ap. J., 230, 540.Google Scholar
Katz, J.I.: 1976, Ap. J., 206, 910.Google Scholar
Lawrence, A.: 1979, M.N.R.A.S., in press.Google Scholar
Lawrence, A., Pye, J.P., Elvis, M.: 1977, M.N.R.A.S., 181, 93P.CrossRefGoogle Scholar
Mushotzky, R.E., Marshall, F.E., Boldt, E.A., Holt, S.S., Serlemitsos, P.J.: 1979, Ap. J., in press.Google Scholar
Primini, F.A., et al.: 1979, Nature, 278, 234.Google Scholar
Ricketts, M.J. Cooke, B.A., Pounds, K.A.: 1976, Nature, 259, 546.Google Scholar
Tananbaum, H., et al.: 1979, Ap. J., in press.Google Scholar