Hostname: page-component-76fb5796d-45l2p Total loading time: 0 Render date: 2024-04-26T04:31:55.669Z Has data issue: false hasContentIssue false

Experiments on terminal disinfection of cubicles with formaldehyde

Published online by Cambridge University Press:  15 May 2009

M. M. Beeby
Affiliation:
Cross-Infection and Disinfection Reference Laboratories, Central Public Health Laboratory, Colindale Avenue, London N. W. 9
D. Kingston
Affiliation:
Cross-Infection and Disinfection Reference Laboratories, Central Public Health Laboratory, Colindale Avenue, London N. W. 9
C. E. Whitehouse
Affiliation:
Cross-Infection and Disinfection Reference Laboratories, Central Public Health Laboratory, Colindale Avenue, London N. W. 9
Rights & Permissions [Opens in a new window]

Extract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The conditions for satisfactory fumigation with formaldehyde were investigated using suspensions of Staph. aureus and Ps. aeruginosa dried as drops on strips of polythene or after mixing with cotton dust. In laboratory experiments with controlled concentrations of formaldehyde and water vapour, satisfactory results were obtained at 86 % humidity, but at 32 % humidity the formaldehyde was virtually inactive.

Measurements under field conditions showed that the permanganate method of vaporizing formaldehyde did not vaporize enough water to produce optimum conditions for sterilization, and that great care was necessary in the sealing of rooms. When sterilization was incomplete the surviving organisms were not uniformly distributed within the room.

In the limited circumstances in which fumigation with formaldehyde is thought to be essential, the process should be controlled by estimating the formaldehyde and water vapour concentrations initially and after 3 hr.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1967

References

American Public Health Association (1965). Control of Communicable Diseases in Man, 10th ed.New York: A.P.H.A.Google Scholar
Beeby, M. M. & Whitehouse, C. E. (1965). A bacterial spore test piece for the control of ethylene oxide sterilization. J. appl. Bact. 28, 349.CrossRefGoogle ScholarPubMed
Gonzaga, A. J., Mortimer, E. A., Wolinsky, E. & Rammelkamp, C. H. (1964). Transmission of staphylococci by fomites. J. Am. med. Ass. 189, 711.CrossRefGoogle ScholarPubMed
Harry, E. G. (1954). The influence of certain chemico-physical characteristics of formaldehyde on its use as a disinfectant. Proc. Xth Wld Poult. Congr. p. 217. Edinburgh.Google Scholar
Harry, E. G. (1959). A method of estimating the formaldehyde vapour concentrations used in egg fumigation. Vet. Rec. 71, 842.Google Scholar
Harry, E. G. (1961). Surface disinfection of poultry buildings by formaldehyde and sulphur dioxide. Vet. Rec. 73, 522.Google Scholar
Harry, E. G. & Hemsley, L. A. (1964). Factors influencing the survival of coliforms in the dust of deep litter houses. Vet. Rec. 76, 863.Google Scholar
Kingston, D., Lidwell, O. M. & Noble, W. C. (1962). Self-disinfecting surface coatings which evolve formaldehyde. Mon. Bull. Minist. Hlth 21, 246.Google ScholarPubMed
Kingston, D. & Noble, W. C. (1964). Tests on self-disinfecting surfaces. J. Hyg., Camb. 62, 519.Google ScholarPubMed
Ministry of Health and Scottish Home and Health Department (1964). Memorandum on the Control of Outbreaks of Smallpox. London: H.M.S.O.Google Scholar
Lancaster, J. E., Gordon, R. F. & Harry, E. G. (1954). Studies on disinfection of eggs and incubators. III. The use of formaldehyde at room temperature for the fumigation of eggs prior to incubation. Br. vet. J. 110, 238.CrossRefGoogle Scholar
Nash, T. (1953). The colorimetric estimation of formaldehyde by means of the Hantzsch reaction. Biochem. J. 55, 416.CrossRefGoogle ScholarPubMed
O'Brien, F. E. M. (1948). The control of humidity by saturated salt solutions. J. scient. Instrum. 25, 73.CrossRefGoogle Scholar
Public Health Laboratory Service (1958 a). Disinfection of fabrics with gaseous formaldehyde. J. Hyg., Camb. 56, 488.Google Scholar
Public Health Laboratory Service (1958 b). The practical aspects of formaldehyde fumigation. Mon. Bull. Minist. Hlth 17, 270.Google Scholar
Walker, J. F. (1964). Formaldehyde, 3rd ed.New York: Reinhold Publishing Corporation.Google Scholar