Hostname: page-component-8448b6f56d-tj2md Total loading time: 0 Render date: 2024-04-25T00:03:56.652Z Has data issue: false hasContentIssue false

Design improvements and tests of a laser positioning system for the Taiwan Photon Source girder system

Published online by Cambridge University Press:  15 December 2010

Keng-Hao Hsu
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
Mei-Ling Chen*
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
H. C. Ho
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
H. S. Wang
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
Y. L. Tsai
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
W. Y. Lai
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
T. C. Tseng
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
S. Y. Perng
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
K. H. Hsu
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
J. R. Chen
Affiliation:
National Synchrotron Radiation Research Center, No.101, Hsin-Ann Road, Hsinchu, 30076, Taiwan, R.O.C.
*
Email address for correspondence: chen.claire@nsrrc.org.tw
Get access

Abstract

A precise laser positioning system had been preliminarily developed for the girder system of the Taiwan Photon Source. This laser positioning system, a part of a girder auto-alignment scheme, will be installed on the girders located at both sides of each straight section of the storage ring. The system is composed of a laser and four sets of a position sensing device (PSD). The laser, held on one girder, propagates 13 m along the girder and plays the role of a reference line of girders of the straight section. Based on the laser linear characteristics, the other girder can be adjusted and aligned by a cam mover according to PSD data. To achieve superior precision, the whole laser positioning system should be constructed stably. After making some improvements to eliminate the unstable terms, the precision of the laser positioning system can achieve 2 µm at 13 m propagating distance every 4 h.

Type
Poster paper
Copyright
Copyright © Diamond Light Source Ltd 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Lai, W. Y., Tseng, T. C., Wang, H. S. & Chen, J. R. 2009 Design and prototype tests of auto-alignment of a whole-ring girder. In Particle Accelerator Conference. Vancouver, BC, Canada.Google Scholar
Wang, H. S., Ho, H. C., Tseng, T. C., Lin, C. J., Hsu, K. H., Wang, D. J. & Chen, J. R. 2008 Design and test of a PSD system for TPS girder. In International Conference on Mechanical Engineering Design of Synchrotron Radiation Equipment and Instrumentation. Saskatchewan, Canada.Google Scholar