Time-Resolved X-Ray Powder Diffractometry Using Lihear Position-Sensitive Proportional Counters

Published online by Cambridge University Press:  06 March 2019

Herbert E. Göbel*
Affiliation:
Foischungslaboratorien der SIEMENS AG, D 8000 Munchen 83 , West Germany
Get access

Abstract

Several examples of time-resolved X-ray powder diffraction studies with linear position-sensitive proportional counters (PSPC) are described. The changing patterns are recorded by spectrum multiplexing in a multichannel counter device. The time resolution for single processes is limited to seconds or tenths of seconds mainly because of the counting statistics of the observed peaks. Repetitive processes, however, where the interesting peaks can be accumulated over a large number of periods, permit much higher time resolution. It is finally determined by the timing of a detected X-ray quantum. Using a continuous beam source like a conventional X-ray tube the incidence of a photon into the PSPC can be timed with an accuracy of 20 ns (fwhm). A pulsed synchrotron radiation source, like a storage ring, will be able to define this resolution to its pulse duration, which is less than 200 ps.

Before approaching those limits this paper presents the high temperature phase transformations in iron for different steel specimens as an example of single processes. It also discusses domain-wall effects and electrostriction in ferroelectric perovskites as a function of polarization at frequencies of up to 10 Hz, and elastic lattice distortions of a steel sheet vibrating at about 200 Hz. The timing limit of 20 ns for the PSPC detection system was measured at the storage ring DORIS at DESY, Hamburg.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1980

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Green, R. E. and Dantzig, J. A., Flash X-Ray Diffsraction Systems, in “Advances In X-Ray Analysis, Vol. 16,” Eirks, L. S., Barrett, Charles S., Newkirk, John B., and Ruud, Clayton O., eds., Plenum Publishing Corp., New York (1973).Google Scholar
2. Johnson, Q. C., Mitchell, A. C., Paper H 5 at the ACA Winter Meeting, March 1979, Honolulu, HawaiiGoogle Scholar
3. Gobel, H. E., A New Method for Fast XRPD Using a Position Sensitive Detector, in “ Advances in X-Ray Analysis, Vol. 22,” McCarthy, G. J., Barrett, C. S., Leyden, D. E., Newkirk, J. B., and Ruud, C. O., eds., Plenum Publishing Corp., New York (1979).Google Scholar
4. Gobel, H. E., “The Use and Accuracy of CPSD-data in XRPD (see contribution in this volume).Google Scholar
5. Huxley, H. E., Faruqui, A. R., Bordas, J., J.|Koch, M. H., J. Milch. Nature (1980) in press.Google Scholar