References Intensity Quantitative Analysis Using Thin-Layer Aerosol Samples

Published online by Cambridge University Press:  06 March 2019

Briant L. Davis*
Affiliation:
Institute of Atmospheric Sciences, South Dakota School of Mines and Technology, Rapid City, South Dakota 57701-3995
Get access

Extract

Interest in the reference intensity ratio CRIR) method continues as a result of the potential capabilities of the technique for rapid multi-component quantitative analysis. The theoretical basis for the RIR technique is now well established (Chung, 1974; Hubbard et al., 1976; Davis, 1980, 1981; Davis and Johnson, 1982), Major areas for which the method can still be greatly improved include the methods used for sample preparation, the measurement of accurate intensities, and the use of an internally consistent set of reference intensity constants (designated RIR, or ki). In the methodology developed at the Institute of Atmospheric Sciences (IAS), South Dakota School of Mines and Technology, sample preparation centers about the suspension of the pulverized sample into an aerosol and collection onto filter media. Because of this step, intensities must be corrected from their raw values to intensities representative of “infinite thickness“ and volumetrically constant conditions of normal sample diffraction. The measurement and correction of intensities and sample preparation methodology is the subject matter of the present paper.

Type
IV. Quantitative Phase Analysis by XRD
Copyright
Copyright © International Centre for Diffraction Data 1983

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Borg, I. Y., and Smith, D. K., 1969, Calculated x-ray powder patterns for silicate minerals, Geoi. Soc. Amer. Mem. Wo. 122.Google Scholar
Calvert, L. D., Sirianni, A., Gainsford, G. J., and Hubbard, C. R., 1983, A comparison of methods for reducing preferred orientation, Adv. in X-ray Analysis, 26 (in press).Google Scholar
Chung, F., 1974, Quantitative interpretation of x-ray diffraction patterns of mixtures. J. Appl. Cryst., 7:519–2.Google Scholar
Davis, B. L., 1980, “Standardless” x-ray diffraction quantitative analysis, Atmos. Environ., 14:217–2.Google Scholar
Davis, B. L., 1981, A study of the errors in x-ray quantitative analysis procedures for aerosols collected on filter media, Atmos. Environ., 15:291–2.Google Scholar
Davis, B. L., and Cho, N-K., 1977, Theory and application of x-ray diffraction compound analysis to high-volume filter samples, Atmos, Environ., 11:7385.Google Scholar
Davis, B. L. and Johnson, L. R., 1982, Sample preparation and methodology for x-ray quantitative analysis of thin aerosol layers deposited on glass fiber and membrane filters, Adv. in X-ray Analysis, 25:295–2.Google Scholar
Davis, B. L., and Walawender, H. J., 1982, Quantitative mineralogical analysis of granitoid rocks:a comparison of x-ray and optical techniques, Amer. Mineralogist, 67:1135–23.Google Scholar
Graf, D. C., 1961, Crystallographic tables for the rhombohedral carbonates, Amer. Mineralogist, 46:1283–26.Google Scholar
Hubbard, C. R., Evans, H. H., Smith, D. K., 1976, The reference intenstiy ratio, I/Ic, for computer simulated powder patterns, J. Appl. Cryst., 9:169–2.Google Scholar