Escape Peak Intensities in Argon/Methane Flow Detectors

Published online by Cambridge University Press:  06 March 2019

M. A. Short
Affiliation:
Ford Motor Company, Research Staff, Dearborn, Michigan 48121
J. Tabock
Affiliation:
Ford Motor Company, Research Staff, Dearborn, Michigan 48121
Get access

Extract

X-ray proportional gas detectors are used in X-ray diffraction and X-ray fluorescence and emission analysis. The amplitude of the electrical pulses produced by these detectors is directly proportional to the energy of the incident X-rays. In most instances, the energy of the incident photons will be utilized completely in producing photo-ionization in the outermost shells of the detector atoms. If the energy of these photons is greater than the absorption edge of the atoms in the detector, a certain fraction of them will produce photo-ionization of an inner shell. This in turn results in the production of a characteristic X-ray. If this characteristic X-ray is absorbed by the detector, then the original X-ray may still be considered to have deposited the whole of its energy within the detector. In this case the amplitude of the detector output pulse will be the same as if the original X-ray photon had been absorbed entirely by photo-ionization of the outer shells. Because of the relatively low absorption of a detector for its own characteristic radiation, there is a significant probability that the detector characteristic X-ray will escape from the detector without producing further photo-ionization.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1980

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Bertin, E. P., “Principles and Practice of X-Ray Spectrometrie Analysis”, pp. 219284, Plenum Press, New York(1978).Google Scholar
2. Jenkins, R. and Hurley, P. W., “Escape Peak Interference in X-Ray Spectrochemical Analysis”, Canadian Spectroscopy, 13: 35 (1968).Google Scholar
3. Short, M. A., Tabock, J. and Hoffman, D. W., “Electron Microprobe Analysis of Rare Gases in Thin Metal Foils with the Use of Surrogate Standards”, Microbeam Analysis - 1980, San Francisco Press, San Francisco (1980).Google Scholar
4. Jenkins, R., “Escape Peak Ratio as a Function of Fluorescent Yield”, Proc. 5th Conf. on X-Ray Anal. Methods, p. 54, N.V. Philips Gloeilampenfabrieken, Eindhoven (1966).Google Scholar
5. Maurice, F. and Ruste, J., “Ensembles de Comptage en Spectrometrie de Rayons X a Dispersion de Longeur d'Onde et a Selection d'Energie: Principe, Controle, Reglage”, pp.13-14, Commissariat a l'Energie Atomique - France, CEA-R-4909(1978).Google Scholar