Hostname: page-component-77c89778f8-5wvtr Total loading time: 0 Render date: 2024-07-18T17:24:52.614Z Has data issue: false hasContentIssue false

Detection of Single Ions by Pulse Counting: Application to Ion Microprobe Mass Analyzer

Published online by Cambridge University Press:  06 March 2019

L. A. Dietz*
Affiliation:
General Electric Company, Knolls Atomic Power Laboratory
Get access

Abstract

The need to detect low intensity beams of resolved ions with keV energy is encountered frequently in mass spectrometry. It is most readily accomplished by using some form of pulse-counting detector in which ions are allowed to strike a target surface (conversion dynode) where each ion releases a pulse of low energy secondary electrons. The secondary electrons undergo further amplification in an electron multiplier or scintillator type of ion detector which is specially designed to detect single ions. Ion-to-electron conversion, amplification of the secondary electrons, efficiency of ion detection by pulse counting and dead-time corrections to observed random counting rates are all statistical processes which must be understood so that observed data can be corrected properly to obtain precise and accurate measurements. These processes are reviewed, along with some of the basic properties of ion-induced secondary electron emission from an amorphous Al2O3 thin film target. Ion detection in the ion microprobe is interpreted in light of these basic considerations, and several mass spectra are given for electron multiplier dynode surfaces.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1971

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. White, F. A. and Collins, T. L., “Positive Ion Counting for Mass Spectrometer Beam Currents of 10-14 to 10-9 Ampere,” Appl. Spectroscopy 8, No. 1, 17(1954).Google Scholar
2. Carter, G. and Colligon, J. S., Ion Bombardment of Solids, (Heinemann Educational Bocks Ltd, London, 1969).Google Scholar
3. Dietz, L. A., “Electron Multipliers and Statistics of Secondary Electron Emission,” 18th Annual Conf. on Mass Spectrometry and Allied Topics, San Francisco, California, June (1970).Google Scholar
4. Parilis, E. S. and Kishinevskii, L. M., “The Theory of lon- Electron Emission,” Transl. Soviet Phys.-Solid State 3, 885 (1960).Google Scholar
5. Schram, B. L., Boerboom, A. J. H., Kleine, W. and Kistemaker, J., “Amplification Factors of a Particle Multiplier for Multiply Charged Noble Gas Ions,” Physica 32, 749 (1966).Google Scholar
6. Kaminsky, M., Atomic and Ionic Impact Phenomena on Metal Surfaces, (Academic Press, 1965), p. 329.Google Scholar
7. Davies, J. A., “The Penetration of keV Projectiles in Solids,” Atomic Energy of Canada Ltd., Rept. No. AEGL-2757, August (1967).Google Scholar
8. Domeij, B., Brown, F., Davies, J. A. and McCargo, M., “Ranges of Heavy Ions in Amorphous Oxides,” Can. J. Phys. 42, 1624 (1964).Google Scholar
9. Collins, R. E. and Davies, L. W., “The Transport of Hot Electrons in Al-AloO^-Al Tunnel Cathodes,” Solid State Electronics, (pergamon Press, 1964), Vol. 7, p 445.Google Scholar
10. Dietz, L. A., “General Method for Computing the Statistics of Charge Amplification in Particle and photon Detectors Used for Pulse Counting,” Int. J. Mass Spectrometry Ion Phys. 5, 11 (1970).Google Scholar
11. Daly, N. R., “Scintillation Type Mass Spectrometer Ion Detector,” Rev, Sci. Instr. 31, 264 (1960).Google Scholar
12. Young, W.A.P., Ridley, R. G. and Daly, N. R., “fast Counting in Mass Spectrometry with the Scintillation Detector,” Nucl. Instr. Meth. 51, 257 (1967).Google Scholar
13. Prescott, J. R., “A Statistical Model for photomultiplier Single Electron Statistics,” Nucl.Instr. Methods 39, 173 (1966).Google Scholar
14. Dietz, L. A., Hance, A. B. and Hanrahan, L. R., “Fabrication of 18-Stage Electron Multiplier,” Knolls Atomic Power Laboratory Rept. KAPL-3352, June (1967).Google Scholar
15. Dietz, L. A., “Basic Properties of Electron Multiplier Ion Detection and Pulse-Counting Methods in Mass Spectrometry, Rev, Sci. Instr. 36, 1763 (1965).Google Scholar
16. Sawada, F. H., “Design Technique for High Speed Pulse Circuitry For Surface Mass Spectrometer,” IIIE Trans. Nucl.Sci., Vol. NS-12, No. 1, 374, Feb. (1965).Google Scholar
17. Hance, A. B. and Hanrahan, L. R., “Further Development of a High-Speed Electron-Multiplier Discriminator for Mass Spectrometer Ion Detection,” Knolls Atomic Power Laboratory Rept. No. KAPL-3122, Feb. (1966).Google Scholar
18. Rainwater, L. J. and Wu, C. S., “Applications of Probability Theory to Nuclear Particle Detection,” Nucleonics, Oct. 1947, p. 60.Google Scholar
19. Dietz, L. A., Pachueki, C. F. and Land, G. A., “Half Lives of Cessium-137 and Cesium-134 as Measured by Mass Spectrometry,” Anal.Chem. 35, 797 (1963).Google Scholar
20. Liebl, H., “Ion Microprobe Mass Analyzer,” J. Appl. Phys. 38, 5277 (1967).Google Scholar
21. Anderson, C. A., “Analytic Methods for the Ion Microprobe Mass Analyzer. Part II,” Int. J. Mass Spectrometry Ion Phys. 3, 413 (1970).Google Scholar
22. Anderson, C. A., “Progress in Analytic Methods for the Ion Microprobe Mass Analyzer,” Int. J. Mass Spectrometry Ion Phys. 2, 61 (1969).Google Scholar