Hostname: page-component-76fb5796d-x4r87 Total loading time: 0 Render date: 2024-04-25T14:45:09.554Z Has data issue: false hasContentIssue false

Compact Thomson Scattering Source Based on a Mixed Injection Assisted Laser Wakefield Accelerator

Published online by Cambridge University Press:  01 January 2024

Fang Tan*
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Xiao Hui Zhang
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Bin Zhu
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Gang Li
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Yu Chi Wu
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Ming Hai Yu
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Yue Yang
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Yong Hong Yan
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Wei Fan
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Ke Gong Dong
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Feng Lu
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Tian Kui Zhang
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
Yu Qiu Gu
Affiliation:
Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang, China
*
Correspondence should be addressed to Fang Tan; tanfang@caep.cn
Rights & Permissions [Opens in a new window]

Abstract

In order to establish a compact all-optical Thomson scattering source, experimental studies were conducted on the 45 TW Ti: sapphire laser facility. By including a steel wafer, mixed gas, and plasma mirror into a double-exit jet, several mechanisms, such as shock-assisted ionization injection, ionization injection, and driving laser reflection, were integrated into one source. So, the source of complexity was remarkably reduced. Electron bunches with central energy fluctuating from 90 to 160 MeV can be produced. Plasma mirrors were used to reflect the driving laser. The scattering of the reflected laser on the electron bunches led to the generation of X-ray photons. Through comparing the X-ray spots under different experimental conditions, it is confirmed that the X-ray photons are generated by Thomson scattering. For further application, the energy spectra and source size of the Thomson scattering source were measured. The unfolded spectrum contains a large amount of low-energy photons besides a peak near 67 keV. Through importing the electron energy spectrum into the Monte Carlo simulation code, the different contributions of the photons with small and large emitting angles can be used to explain the origin of the unfolded spectrum. The maximum photon energy extended to about 500 keV. The total photon production was 107/pulse. The FWHM source size was about 12 μm.

Type
Research Article
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright
Copyright © 2022 Fang Tan et al.

1. Introduction

When photons are scattered by relativistic electrons, the so-called Thomson scattering process can increase the photon energy by approximately 4γ 2 times [Reference Einstein1, Reference Thomson2], where γ is the normalized electron energy. Based on this process, the Thomson scattering source possesses a set of valuable features, including compactness, tunable photon energy, potential for the duration of femtosecond time scale, and high brightness [Reference Sprangle, Ting, Esarey and Fisher3, Reference Sprangle and Esarey4]. In many application areas, such as phase-contrast imaging of organisms [Reference Attwood5], shadow imaging of high-Z materials [Reference Joshi and Corkum6], stimulating nuclear resonance fluorescence (NRF) of specific isotopes [Reference Albert7Reference Lan, Song, Luo, Zhou, Zhu and Luo9], and ultra-fast pump-probe detection of transient physical and chemical processes [Reference Wilhelm, Gruber and Schwestka10], the Thomson scattering source may play a unique role.

For established, conventional Thomson scattering sources [Reference Gibson, Anderson and Barty11Reference Huang, Pan and Li15], where the electrons are produced by a classical electron accelerator, the huge size and ultra-expensive cost required by the large-scale classical electron accelerators restrict further applications. As an improvement, an all-optical Thomson scattering X-ray source has been proposed by Catravas et al. in 2001 [Reference Catravas, Esarey and Leemans16], where the electrons are produced by the laser-plasma wakefield accelerator. This accelerator can produce quasi-monoenergetic electron beams with low divergence, small energy spread, and ultra-short pulse duration [Reference Esarey, Hubbard, Leemans, Ting and Sprangle17Reference Umstadter, Kim and Dodd19]. Due to the ultra-high accelerating gradient, electrons can be accelerated toward tens of MeV to several GeV within a distance of mm scale [Reference Faure, Glinec and Pukhov20Reference Mangles, Murphy and Najmudin23]. So, the all-optical Thomson scattering source is a very promising way to establish a compact, ultra-fast, quasi-monoenergetic X-ray source.

The first successful experimental results of all-optical Thomson scattering sources were obtained in 2006 [Reference Schwoerer, Liesfeld, Schlenvoigt, Amthor and Sauerbrey24], where photons with energies ranging from 400 eV to 2 keV were produced by two counter-propagating laser pulses. Based on these two laser collision models, several studies have been conducted, including the improvement of the source stability [Reference Chen, Powers and Ghebregziabher25, Reference Powers, Ghebregziabher and Golovin26], extending the electron maximum energy to 18 MeV through nonlinear Thomson scattering [Reference Sarri, Corvan and Schumaker27], and a way to obtain sources with tunable energy [Reference Khrennikov, Wenz and Buck28]. High-order multiphoton (n, 500) Thomson scattering signals were also obtained in 2017 [Reference Yan, Fruhling and Golovin29]. In 2012, a compact all-optical Thomson scattering source was reported [Reference Ta Phuoc, Corde and Thaury30], where a plasma mirror (PM) was used to directly reflect the driving laser. In this method, the temporal and spatial synchronization between laser and electrons can be realized more easily. Several compact all-optical Thomson scattering sources have been established based on this method [Reference Ma, Hua and Liu31Reference Zhu, Wang and Feng34].

In order to improve the stability of the generation of wakefield electrons and Thomson scattering sources, the shock assistant ionization injection technique has proved its validity [Reference Buck, Wenz and Xu35, Reference Thaury, Guillaume and Lifschitz36]. The studies on the cascaded acceleration technique [Reference Golovin, Chen and Powers37Reference Wang, Li and Liu39] also show the advantages of this technique for producing high-quality electrons. The above studies show that the integration of multi-injection technologies within one accelerator has the potential to generate Thomson scattering sources with better stability and higher production. But at present, the studies on the all-optical Thomson scattering source containing multi injection and acceleration techniques are insufficient.

The integration of multitechnologies within one accelerator requires proper designing on the compactness of the accelerator. In our previous studies [Reference Tan, Zhang and Zhu40], we have established a compact laser wakefield accelerator where shock-assisted ionization injection and ionization injection were integrated into a double-exit gas jet. Based on this accelerator and a plasma mirror attached to the gas jet, a compact all-optical Thomson scattering source can be established.

In the following paragraphs, the experimental layout and the obtained electron energy spectra are shown. Then, after the driving laser was reflected by the plasma mirror, the scattering of the reflected laser on the electron bunch led to the generation of X-ray photons. Through comparing the X-ray spots under different experimental conditions, it is confirmed that the X-ray photons were produced by Thomson scattering. The location of the plasma mirror was also optimized. At last, the energy spectra and source size of the Thomson scattering source were measured for further application.

2. Experimental Parameters

The experiments were performed on the 45 TW, 25 fs, 800 nm Ti: sapphire laser facility at the Laser Fusion Research Center of CAEP in Mianyang. The laser is linearly polarized in the horizontal direction. The laser focal spot is 11.9 × 7.8 μm full width at half maximum (FWHM) with 60% energy in the spot. In the experiments, the initial input power was set at 28 TW. The total energy coupling efficiency to the target is 70%. So, the peak laser intensity at the focus is I = 1.81 × 1019 W/cm2, corresponding to a normalized intensity of a 0 = 2.9. The experimental layout is shown in Figure 1(a). A gas jet containing two nozzles is used as the target. The first nozzle is a cylindrical hole with an exit diameter of 1 mm and higher gas pressure. The second nozzle is a conical hole with an exit diameter of 2 mm and lower gas pressure. The shock front is produced by the impact between the gas jets from the two nozzles. The addition of a wafer can reduce the exit size of nozzle 1, leading to higher jet density and a shock front with higher density and a steeper falling edge. Mixed gas containing 97.5% He and 2.5% N2 is used. In the first nozzle, the electron is injected from shock-assisted ionization injection. Then, the accelerated electrons are injected into the second nozzle. A 75 m thick plasma mirror (PM) made of polyethylene terephthalate (PET) is attached to the exit edge of the second nozzle. After being reflected by the plasma mirror, the driving laser interacts with the wakefield electrons for the second time, generating X-ray photons.

Figure 1: (a) The gas jet designment and the experimental layout. The view of the gas jet is enlarged. (b) The side view of the gas density distribution. (c) The one-dimensional electron density at a height of 2 mm from the gas jet.

A spectrometer consisting of a permanent magnet (0.8 T with a length of 230 mm) and a phosphor screen imaged using a 16-bit CCD camera is used to deflect the electrons and measure the electron energy spectra. The produced X-ray photons emit out of the vacuum chamber through a 300 μm beryllium window. An X-ray camera consisting of a CsI: Tl scintillator, a fiber taper, and a 16-bit CCD sensor records the spatial distribution of the X-ray photons. The X-ray spectra are measured by using a filter stack spectrometer [Reference Yu, Tan and Yan41]. The X-ray source size is measured using the knife-edge imaging method [Reference Kneip, McGuffey and Martins42].

3. Experimental Results

In our previous works, we established a laser wakefield accelerator with a mixed injection mechanism [Reference Tan, Zhang and Zhu40]. Based on this accelerator, stable monoenergetic wakefield electron beams with a central energy of 60 MeV were experimentally obtained. To increase the electron energy, the gas pressure of the jet was increased from 650 kPa to 1100 kPa. Under the higher gas pressure, electrons can be steadily produced, but the electron central energy fluctuates from 90 MeV to 160 MeV, as shown in Figure 2. All of the electron energy spectra in this paper are on the same color bar as in Figure 2. The instability of electron spectra in Figure 2 comes from the instability of the gas pressure and laser energy. The nonlinear evolution of the laser in the relatively high gas pressure (1100 kPa) also leads to the fluctuation of electron energy. Actually, when the gas pressure was adjusted to about 600 kPa as in our previous experiments [Reference Tan, Zhang and Zhu40], the electron spectra with better stability and lower production were obtained. In our further studies, the optimization of the gas jet may lead to a better control of the injection process and smaller energy spread. The improvement in the stability and output power of the laser facility may lead to more stable electron production and higher electron energy.

Figure 2: The electron energy spectra under a gas pressure of 1100 kPa.

Based on this accelerator, several kinds of X-ray sources can be produced. A Thomson scattering source can be produced through the scattering of the reflected driving laser on the electrons. Betatron radiation with photon energy ranging from hundreds of electronvolts to several tens of kiloelectron volts can be produced through the oscillation of the electrons in the wakefield. Bremsstrahlung can be produced when the electrons penetrate the plasma mirror. The direct interaction between the driving laser and the plasma mirror may also produce bremsstrahlung. To distinguish the signals of Thomson scattering from the other sources, the X-ray spots under different conditions are recorded as shown in Figure 3. In Figure 3(a), a pristine plasma mirror is used, and wakefield electrons are efficiently produced. All of the possible signals, such as signals from the Thomson scattering, Betatron radiation, and bremsstrahlung, could be produced and recorded by the X-ray camera. Figure 3(a) shows that strong and clear X-ray signals were recorded. Then, when there is no plasma mirror, the driving laser cannot be reflected. Bremsstrahlung and Thomson scattering radiation cannot be generated. Betatron radiation can be generated, but only photons with energy higher than 2 keV can penetrate the beryllium window and get recorded by an X-ray camera. The obtained result is shown in Figure 3(b), where no obvious signal is recorded. When the plasma mirror was placed farther from the gas jet, defocusing of the laser reduced the corresponding intensity. So, the laser reflection on the plasma mirror and the radiation intensity from the Thomson scattering were drastically reduced. Only Betatron radiation and bremsstrahlung can be produced as a result of electron-plasma mirror interaction. But similar to Figure 3(b), the recorded result in Figure 3(c) shows no obvious result. So, it is clear that the contributions of betatron radiation and bremsstrahlung can be ignored.

Figure 3: The X-ray spots under different experimental conditions and the corresponding electron spectra.

Finally, the variability of the electron injection at higher pressures causes instability of the wakefield acceleration. Some shots under the same conditions as in Figure 3(a) resulted in poor electron beam generation. Figure 3(d) gives an example of such a result with no obvious X-ray images from Thomson scattering. All of the results in Figure 3 show that only with pristine, properly placed plasma mirror, and efficient laser wakefield acceleration, distinct X-ray signals can be recorded. Only effective Thomson scattering can result in the X-ray spot as shown in Figure 3(a). In Figure 3(a), the FWHM emitting angle of the X-ray source is 30 mrad.

To find the optimized position of the plasma mirrors, the average intensity of the X-ray spots recorded by CCD at different plasma mirror positions is shown in Figure 4. In this figure, position 0 corresponds to the exit edge of the gas jet. When the plasma mirror moves away from the gas jet, it moves from the edge part of the gas jet to a vacuum. The optimized plasma mirror position of 0.1 mm shown in Figure 4 reflects the position in the edge part of the gas jet with the highest laser reflectivity. Then, in vacuum, when the plasma mirror moves away from the gas jet, the laser beam size increases at the colliding point, leading to a decrease in laser intensity, reflectivity, and X-ray intensity. The incidence angle of laser photons in vacuum may be larger than the incidence angle of the guided laser in the gas jet. So qualitatively, the energy spread of the X-ray spectra in vacuum will be larger than that in the gas jet. But when the plasma mirror moves in vacuum, the interaction angles between electrons and laser photons stay unchanged, leading to a nearly unchanged spectra profile.

Figure 4: The average intensity of X-ray spots versus the plasma mirror position.

Next, we used the previously established filter stack spectrometer [Reference Yu, Tan and Yan41] to measure the energy spectra of the obtained Thomson scattering source. For the electron bunch with the energy spectrum as in Figure 5(a), the different X-ray profiles behind a set of stacked filters are shown in Figure 5(b). Based on the results in Figure 5(b), the input X-ray spectrum within the emitting angle of 20 mrad can be unfolded. The unfolded spectrum in Figure 5(c) shows that the spectrum contains a large number of low-energy photons besides a peak near 67 keV. The maximum photon energy extends to about 500 keV. In the electron energy spectrum in Figure 5(a), there is a small part of electrons with energy of 150 MeV. So, the production of photons with energy of 500 keV can be attributed to the Thomson scattering of laser photons on these high-energy electrons. The contribution of the nonlinear Thomson scattering effect should also be considered. In our experiments, the peak laser intensity at the focus is I = 1.81 × 1019 W/cm, corresponding to a normalized intensity of a 0 = 2.9. The laser spot at 0.1 mm away from the jet exit is nearly unchanged. If the reflectivity on the plasma mirror is assumed to be 50%, the intensity of the reflected can be estimated as 0.9 × 1019 W/cm, corresponding to normalized intensity a 0 = 2.05. So, under this intensity, the nonlinear Compton scattering effect may lead to an inapparent contribution. Based on the obtained spectrum in Figure 5(c), the total photon production can be estimated as 107/pulse.

Figure 5: (a) The electron energy spectrum. (b) The corresponding X-ray profiles behind a set of stacked filters. (c) The unfolded spectrum.

In order to find the origin of these low-energy photons, the electron energy spectrum in Figure 5(a) can be imported into the Monte Carlo simulation code CAIN [Reference Chen, Hortonsmith, Ohgaki, Weidemann and Yokoya43] to obtain the theoretical radiation spectrum. The calculation parameters are the same as the experimental parameters. The relation between photon energy and emitting angle is shown in Figure 6(a), which is a traditional angular-energy distribution of the Thomson scattering source. The red and yellow dots in Figure 6(a) correspond to the microphotons with the highest weight, reflecting the electrons in the peak of the electron energy spectrum in Figure 5(a). Due to momentum and energy conservation, the energy of the photons scattered toward a larger angle is always smaller. On the contrary, photons with higher energy mainly emit out within an angle smaller than 5 mrad. The integrated photon energy spectra for integration angles of 5, 10, and 20 mrad are shown in Figure 6(b). The red solid line in Figure 6(b) shows that the photons emitting out at an angle of 5 mrad mainly contribute to the higher energy part of the spectrum. When photons within a larger emitting angle are included in the integration, the black and blue dashed lines in Figure 6(b) show that the low-energy part of the spectra is drastically enhanced. The different contributions of the photons with small and large emitting angles can be used to explain the similar spectral shapes in Figures 5(c) and 6(b). But restricted by the limited filter numbers in the filter stack spectrometer, the photon energy of the unfold spectrum in Figure 5(c) is a bit lower than the calculated results in Figure 6(b). In our further studies, the energy spectra may be more precisely measured with the improvement in the filter stack spectrometer.

Figure 6: (a) The relation between photon energy and emitting angle. Weight is the photon number of each microparticle. (b) The integrated energy spectra of the emitting photons for an integration angle of 5, 10, and 20 mrad.

The obtained source can be used for radiography, where the resolution is one of the most important parameters. For a knife-edge made of 100 μm lead foil, its radiograph image is shown in Figure 7(a). If the source profile is set as a Gaussian shape, the unfolded source size (FWHM) is 12 μm, as shown in Figure 7(b). It also shows that a gold grid used in the electron microscope with a grid size of 2000 mesh × 12.5 μm pitch per inch and a diameter of 3.05 mm was also used. The thickness of the grid is only 3 μm, so the radiation source directly penetrates the grid, leading to a fuzzy circle in Figure 7.

Figure 7: (a) Radiograph of a knife-edge and a gold grid. (b) The unfolded source size.

4. Summary and Discussion

This work reports our studies on the compact all-optical Thomson scattering source. By including a steel wafer, mixed gas, and plasma mirror into a double-exit jet, several mechanisms, such as shock-assisted ionization injection, ionization injection, and driving laser reflection, are integrated. In this compact source, only one gas supply system is required. The source complexity is remarkably reduced. The laser wakefield accelerator with a mixed injection mechanism can steadily produce electron bunches with a central energy fluctuating from 90 MeV to 160 MeV. Then, the driving laser is reflected by the plasma mirror and scatters on the electron bunch, leading to the generation of X-ray photons. By comparing the X-ray spots under different experimental conditions, it is confirmed that the recorded signals by the X-ray camera are produced by Thomson scattering. For further application, we used a filter stack spectrometer to measure the X-ray energy spectra. The unfolded spectrum has a similar spectral shape to the calculated results, which can be explained by different contributions of photons at small and large emitting angles. The maximum photon energy extends to about 500 keV. The total photon production is 107/shot. By using the knife-edge method, the FWHM source size can be measured as about 12 μm.

In our further studies, the optimization of the gas jet may lead to better control of the injection process and smaller energy spread. The improvement in the stability and output power of the laser facility may lead to a more stable electron production and higher electron energy. Moreover, the energy spectra and source size can be more precisely measured with the modification of the corresponding diagnostic techniques.

Data Availability

The data, models, and code generated or used in this study are included within the article.

Conflicts of Interest

The authors declare that they have no conflicts of interest.

Acknowledgments

This work was supported by the Science Challenge Program (TZ2018005), the Presidential Foundation of China Academy of Engineering Physics (2014-1-017), NSAF (U1630246), and the National Key R & D Program (2016YFA0401100).

References

Einstein, A., “Euclidean model of space and time,Annals of Physics, vol. 322, no. 10, pp. 891921, 1905.10.1002/andp.19053221004CrossRefGoogle Scholar
Thomson, J. J., Conduction of Electricity through Gases, Cambridge University Press, Cambridge, UK, 1906.Google Scholar
Sprangle, P., Ting, A., Esarey, E., and Fisher, A., “Tunable, short pulse hard x-rays from a compact laser synchrotron source,Journal of Applied Physics, vol. 72, no. 11, pp. 50325038, 1992.10.1063/1.352031CrossRefGoogle Scholar
Sprangle, P. and Esarey, E., “Interaction of ultrahigh laser fields with beams and plasmas,Physics of Fluids B: Plasma Physics, vol. 4, no. 7, pp. 22412248, 1992.10.1063/1.860192CrossRefGoogle Scholar
Attwood, D., Soft X-Rays and Extreme Ultraviolet Radiation: Principles and Applications, Cambridge University Press, Cambridge, UK, 1999.10.1017/CBO9781139164429CrossRefGoogle Scholar
Joshi, C. J. and Corkum, P. B., “Interactions of ultra‐intense laser light with matter,Physics Today, vol. 48, no. 1, pp. 3643, 1995.10.1063/1.881451CrossRefGoogle Scholar
Albert, F., “Compton scattering source and applications at LLNL,AIP Conference Proceedings, vol. 1299, p. 550, 1995.Google Scholar
Ali, K., Zen, H., Ohgaki, H. et al., “Fusion visualization technique to improve a three-dimensional isotope-selective CT image based on nuclear resonance fluorescence with a gamma-CT image,Applied Sciences, vol. 11, no. 24, Article ID 11866, 2021.10.3390/app112411866CrossRefGoogle Scholar
Lan, H. Y., Song, T., Luo, Z. H., Zhou, J. L., Zhu, Z. H., and Luo, W., “Isotope-sensitive imaging of special nuclear materials using computer tomography based on scattering nuclear resonance fluorescence,Physical Review Applied, vol. 16, no. 5, Article ID 054048, 2021.10.1103/PhysRevApplied.16.054048CrossRefGoogle Scholar
Wilhelm, R. A., Gruber, E., Schwestka, J. et al., “Interatomic coulombic decay: the mechanism for rapid deexcitation of hollow atoms,Physical Review Letters, vol. 119, no. 10, Article ID 103401, 2017.10.1103/PhysRevLett.119.103401CrossRefGoogle ScholarPubMed
Gibson, D. J., Anderson, S. G., Barty, C. P. J. et al., “PLEIADES: a picosecond compton scattering X-ray source for advanced backlighting and Time-resolved material studies,Physics of Plasmas, vol. 11, no. 5, pp. 28572864, 2004.10.1063/1.1646160CrossRefGoogle Scholar
Leemans, W. P., Schoenlein, R. W., Volfbeyn, P. et al., “X-ray based subpicosecond electron bunch characterization using 90 Thomson scattering,Physical Review Letters, vol. 77, no. 20, pp. 41824185, 1996.10.1103/PhysRevLett.77.4182CrossRefGoogle ScholarPubMed
Pogorelsky, I. V., Ben-Zvi, I., Hirose, T. et al., “Demonstration of 8 × 1018 photons/second peaked at 1.8 Å in a relativistic Thomson scattering experiment,Physical Review ST Accelerators Beams, vol. 3, no. 9, Article ID 090702, 2000.Google Scholar
Schoenlein, R. W., Leemans, W. P., Chin, A. H. et al., “Femtosecond X-ray pulses at 0.4 Å generated by 90° Thomson scattering: a tool for probing the structural dynamics of materials,Science, vol. 274, no. 5285, pp. 236238, 1996.10.1126/science.274.5285.236CrossRefGoogle Scholar
Huang, C. X., Pan, W. H., Li, R. K. et al., “Tsinghua Thomson scattering X-ray source,Nuclear Instruments and Methods A, vol. 608, no. 1, pp. S70S74, 2009.Google Scholar
Catravas, P., Esarey, E., and Leemans, W. P., “Femtosecond X-rays from Thomson scattering using laser wakefield accelerators,Measurement Science and Technology, vol. 12, no. 11, pp. 18281834, 2001.10.1088/0957-0233/12/11/310CrossRefGoogle Scholar
Esarey, E., Hubbard, R. F., Leemans, W. P., Ting, A., and Sprangle, P., “Electron injection into plasma wakefields by colliding laser pulses,Physical Review Letters, vol. 79, no. 14, pp. 26822685, 1997.10.1103/PhysRevLett.79.2682CrossRefGoogle Scholar
Esarey, E., Schroeder, C. B., Leemans, W. P., and Hafizi, B., “Laser induced electron trapping in plasma-based accelerators,Physics of Plasmas, vol. 6, no. 5, pp. 22622268, 1999.10.1063/1.873478CrossRefGoogle Scholar
Umstadter, D., Kim, J. K., and Dodd, E., “Laser injection of ultrashort electron pulses into wakefield plasma waves,Physical Review Letters, vol. 76, no. 12, pp. 20732076, 1996.10.1103/PhysRevLett.76.2073CrossRefGoogle ScholarPubMed
Faure, J., Glinec, Y., Pukhov, A. et al., “A laser-plasma accelerator producing monoenergetic electron beams,Nature, vol. 431, no. 7008, pp. 541544, 2004.10.1038/nature02963CrossRefGoogle ScholarPubMed
Geddes, C. G. R., Toth, C., van Tilborg, J. et al., “High-quality electron beams from a laser wakefield accelerator using plasma-channel guiding,Nature, vol. 431, no. 7008, pp. 538541, 2004.10.1038/nature02900CrossRefGoogle ScholarPubMed
Gonsalves, A. J., Nakamura, K., Daniels, J. et al., “Petawatt laser guiding and electron beam acceleration to 8 GeV in a laser-heated capillary discharge waveguide,Physical Review Letters, vol. 122, Article ID 084801, 2019.10.1103/PhysRevLett.122.084801CrossRefGoogle Scholar
Mangles, S. P. D., Murphy, C. D., Najmudin, Z. et al., “Monoenergetic beams of relativistic electrons from intense laser-plasma interactions,Nature, vol. 431, no. 7008, pp. 535538, 2004.10.1038/nature02939CrossRefGoogle ScholarPubMed
Schwoerer, H., Liesfeld, B., Schlenvoigt, H.-P., Amthor, K.-U., and Sauerbrey, R., “Thomson-backscattered X rays from laser-accelerated electrons,Physical Review Letters, vol. 96, no. 1, Article ID 014802, 2006.10.1103/PhysRevLett.96.014802CrossRefGoogle ScholarPubMed
Chen, S., Powers, N. D., Ghebregziabher, I. et al., “MeV-energy X rays from inverse compton scattering with laser-wakefield accelerated electrons,Physical Review Letters, vol. 110, no. 15, Article ID 155003, 2013.Google ScholarPubMed
Powers, N. D., Ghebregziabher, I., Golovin, G. et al., “Quasi-monoenergetic and tunable X-rays from a laser-driven Compton light source,Nature Photonics, vol. 8, no. 1, pp. 2831, 2013.10.1038/nphoton.2013.314CrossRefGoogle Scholar
Sarri, G., Corvan, D. J., Schumaker, W. et al., “Ultrahigh brilliance multi-MeVγ-ray beams from nonlinear relativistic Thomson scattering,Physical Review Letters, vol. 113, no. 22, Article ID 224801, 2014.10.1103/PhysRevLett.113.224801CrossRefGoogle ScholarPubMed
Khrennikov, K., Wenz, J., Buck, A. et al., “Tunable all-optical quasimonochromatic Thomson X-ray source in the nonlinear regime,Physical Review Letters, vol. 114, no. 19, Article ID 195003, 2015.10.1103/PhysRevLett.114.195003CrossRefGoogle ScholarPubMed
Yan, W. C., Fruhling, C., Golovin, G. et al., “High-order multiphoton Thomson scattering,Nature Photonics, vol. 11, no. 8, pp. 514520, 2017.10.1038/nphoton.2017.100CrossRefGoogle Scholar
Ta Phuoc, K., Corde, S., Thaury, C. et al., “All-optical compton gamma-ray source,Nature Photonics, vol. 6, no. 5, pp. 308311, 2012.10.1038/nphoton.2012.82CrossRefGoogle Scholar
Ma, Y., Hua, J. F., Liu, D. X. et al., “Region-of-interest micro-focus computed tomography based on an all-optical inverse compton scattering source,Matter and Radiation at Extremes, vol. 5, no. 6, Article ID 064401, 2020.10.1063/5.0016034CrossRefGoogle Scholar
Tsai, H. E., Wang, X. M., Shaw, J. M. et al., “Compact tunable compton x-ray source from laser-plasma accelerator and plasma mirror,Physics of Plasmas, vol. 22, no. 2, Article ID 023106, 2015.10.1063/1.4907655CrossRefGoogle Scholar
Yu, C. H., Qi, R., Wang, W. T. et al., “Ultrahigh brilliance quasi-monochromatic MeV -rays based on self-synchronized all-optical compton scattering,Scientific Reports, vol. 6, no. 1, Article ID 29518, 2016.Google ScholarPubMed
Zhu, C. Q., Wang, J. G., Feng, J. et al., “Inverse compton scattering x-ray source from laser electron accelerator in pure nitrogen with 15 TW laser pulses,Plasma Physics and Controlled Fusion, vol. 61, no. 2, Article ID 024001, 2018.Google Scholar
Buck, A., Wenz, J., Xu, J. et al., “Shock-front injector for high-quality laser-plasma acceleration,Physical Review Letters, vol. 110, no. 18, Article ID 185006, 2013.10.1103/PhysRevLett.110.185006CrossRefGoogle ScholarPubMed
Thaury, C., Guillaume, E., Lifschitz, A. et al., “Shock assisted ionization injection in laser-plasma accelerators,Scientific Reports, vol. 5, no. 1, Article ID 16310, 2015.10.1038/srep16310CrossRefGoogle ScholarPubMed
Golovin, G., Chen, S., Powers, N. et al., “Tunable monoenergetic electron beams from independently controllable laser-wakefield acceleration and injection,Physical Review ST Accelerators and Beams, vol. 18, no. 1, Article ID 011301, 2015.10.1103/PhysRevSTAB.18.011301CrossRefGoogle Scholar
Liu, J. S., Xia, C. Q., Wang, W. T. et al., “All-Optical cascaded laser wakefield accelerator using ionization-induced injection,Physical Review Letters, vol. 107, no. 3, Article ID 035001, 2011.10.1103/PhysRevLett.107.035001CrossRefGoogle ScholarPubMed
Wang, W. T., Li, W. T., Liu, J. S. et al., “High-brightness high-energy electron beams from a laser wakefield accelerator via energy chirp control,Physical Review Letters, vol. 117, no. 12, Article ID 124801, 2016.Google ScholarPubMed
Tan, F., Zhang, X. H., Zhu, B. et al., “Mixed injection mechanism assisted cascaded laser wakefield accelerator,Acta Physica Sinica, vol. 68, no. 17, Article ID 175201, 2019.10.7498/aps.68.20190484CrossRefGoogle Scholar
Yu, M. H., Tan, T., Yan, Y. H. et al., “A filter stack spectrometer for spectrum measurement of laser generated gamma ray, developlasma mirrorent of filter stack spectrometer for spectrum measurement of X ray generated by laser,Atomic Energy Science and Technology, vol. 51, p. 1090, 2017.Google Scholar
Kneip, S., McGuffey, C., Martins, J. L. et al., “Bright spatially coherent synchrotron X-rays from a table-top source,Nature Physics, vol. 7, no. 9, p. 737, 2011.10.1038/nphys2093CrossRefGoogle Scholar
Chen, P., Hortonsmith, G. A., Ohgaki, T., Weidemann, A. W., and Yokoya, K., “CAIN: conglomrat d’ABEL et d’interactions non-linaires,Nuclear Instruments and Methods A, vol. 355, p. 107, 1994.10.1016/0168-9002(94)01186-9CrossRefGoogle Scholar
Figure 0

Figure 1: (a) The gas jet designment and the experimental layout. The view of the gas jet is enlarged. (b) The side view of the gas density distribution. (c) The one-dimensional electron density at a height of 2 mm from the gas jet.

Figure 1

Figure 2: The electron energy spectra under a gas pressure of 1100 kPa.

Figure 2

Figure 3: The X-ray spots under different experimental conditions and the corresponding electron spectra.

Figure 3

Figure 4: The average intensity of X-ray spots versus the plasma mirror position.

Figure 4

Figure 5: (a) The electron energy spectrum. (b) The corresponding X-ray profiles behind a set of stacked filters. (c) The unfolded spectrum.

Figure 5

Figure 6: (a) The relation between photon energy and emitting angle. Weight is the photon number of each microparticle. (b) The integrated energy spectra of the emitting photons for an integration angle of 5, 10, and 20 mrad.

Figure 6

Figure 7: (a) Radiograph of a knife-edge and a gold grid. (b) The unfolded source size.