Hostname: page-component-848d4c4894-pjpqr Total loading time: 0 Render date: 2024-06-19T14:35:04.777Z Has data issue: false hasContentIssue false

SCE Frequency Measurement Could Be Useful in the Prenatal Diagnosis of Roberts Syndrome

Published online by Cambridge University Press:  21 February 2012

Nenad Bukvic*
Affiliation:
Department of Internal and Public Medicine-Section of Medical Genetics, University of Bari, Bari, Italy. nenadbukvic@virgilio.it
Nicoletta Resta
Affiliation:
Department of Biomedicine of Evolutive Age-Section of Medical Genetics, University of Bari, Bari, Italy.
Dragoslav Bukvic
Affiliation:
Department of Gynaecology, General Hospital, Niksic, Montenegro.
Francesco C. Susca
Affiliation:
Department of Internal and Public Medicine-Section of Medical Genetics, University of Bari, Bari, Italy.
Rosanna Bagnulo
Affiliation:
Department of Biomedicine of Evolutive Age-Section of Medical Genetics, University of Bari, Bari, Italy.
Margherita Fanelli
Affiliation:
Department of Internal and Public Medicine-Section of Imaging Medicine, University of Bari, Bari, Italy.
Ginevra Guanti
Affiliation:
Department of Biomedicine of Evolutive Age-Section of Medical Genetics, University of Bari, Bari, Italy.
*
*Address for correspondence: Nenad Bukvic, DIMIMP- Section of Medical Genetics, University of Bari, Policlinico Piazza G. Cesare, 11, 70124 Bari, Italy.

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

In a previously published article (Resta et al., 2006) on Robert's syndrome in prenatal diagnosis, a case of a 36-year-old woman and her 36-year-old, nonconsanguineous husband were presented. Our findings suggest the existence of nonsense mediated decay (NMD) variability which could account for the varying severity reported in carriers of identical mutations. Furthermore, fetal cells were used to evaluate the influence of premature centromere separation (PCS) on the sister chromatid exchange (SCE) and micronucleus (MN) frequency. Given the similar variation observed in the SCE frequencies, dependent on tissue/cell type (amniotic fluid sample, chorionic villus sampling) and duration of in vitro cultures (48 hours or 72 hours), the idea was that this new piece of information could be interesting. It seems that the SCE frequency increased proportionally to the cell cycle increasing (1° < 2° < 3° … n). Obviously, our observations are too scarce to draw conclusions, but further investigation could be useful to corroborate or dispute these results, considering that the two techniques, (MN and SCE), are simple to perform and do not require expensive laboratory equipment.